NanoVNA v2 S-A-A-2: 50kHz-3000MHz+ Portable Vector Network Analyzer w/ 2.8" LCD Screen & SOLT Calibration Kit
- ୟୁନିଟ୍ ମୂଲ୍ୟ
- / ପ୍ରତି
NanoVNA v2 S-A-A-2: 50kHz-3000MHz+ Portable Vector Network Analyzer w/ 2.8" LCD Screen & SOLT Calibration Kit
The NanoVNA v2 S-A-A-2 is a compact, high-performance portable vector network analyzer designed for RF and microwave engineers who require precise impedance, S-parameter, and transmission line measurements in field and laboratory environments. This instrument measures complex scattering parameters across a frequency range from 50kHz to 3000MHz and beyond, enabling accurate characterization of antennas, filters, amplifiers, and transmission lines without requiring bulky benchtop equipment. The included SOLT (Short-Open-Load-Through) calibration kit ensures measurement accuracy and repeatability, making it indispensable for antenna tuning, PCB trace impedance verification, component testing, and RF circuit debugging in professional and educational settings.
Product Overview
The NanoVNA v2 S-A-A-2 operates on the principle of vector network analysis, where a stimulus signal is transmitted through a device under test and the reflected and transmitted signals are measured with both magnitude and phase information. The analyzer uses a built-in RF bridge circuit and precision mixers to down-convert high-frequency signals to intermediate frequencies, which are then digitized and processed by a dual-core ARM processor. This architecture enables real-time computation of S-parameters (S11, S21, S12, S22), impedance (Z), admittance (Y), reflection coefficient (Gamma), VSWR, and group delay across the entire frequency range, all displayed on a crisp 2.8-inch color LCD touchscreen with intuitive menu navigation.
What distinguishes the NanoVNA v2 S-A-A-2 from its predecessors is its enhanced frequency coverage extending beyond 3GHz, improved dynamic range exceeding 100dB, and superior phase accuracy through advanced calibration algorithms. The instrument features two independent RF ports with SMA connectors, allowing simultaneous measurement of forward and reverse transmission characteristics. Built-in memory stores up to 100 measurement configurations and calibration profiles, while USB connectivity enables data export for post-processing in MATLAB, Excel, or custom analysis software. The rechargeable lithium battery provides 4-5 hours of continuous operation, making it ideal for field surveys, on-site antenna commissioning, and mobile network optimization tasks where AC power is unavailable.
Key Specifications
| Specification | Details |
| Product Type | Portable Vector Network Analyzer |
| Brand | NanoVNA |
| Origin | Original/Authentic |
| Warranty | 7 days on manufacturing defects |
| Shipping | 1-5 days from Bengaluru |
| Delivery | 7-8 days across India |
| Support | 24/7 via Email and WhatsApp |
| Frequency Range | 50kHz to 3000MHz+ (3GHz) |
| Display | 2.8-inch color LCD touchscreen |
| Dynamic Range | Greater than 100dB |
| Calibration Kit | SOLT (Short-Open-Load-Through) included |
| RF Connectors | SMA male connectors (dual ports) |
| Battery Life | 4-5 hours continuous operation |
Key Features
- Extended Frequency Coverage: 50kHz to 3000MHz+ enables characterization of ultra-wideband components, cellular antennas, and microwave circuits with a single instrument
- Dual Independent RF Ports: Simultaneous measurement of S11, S21, S12, and S22 parameters without port switching, reducing measurement time and improving repeatability
- High Dynamic Range: Greater than 100dB dynamic range allows detection of weak reflections and low-loss components with minimal noise floor interference
- SOLT Calibration Kit Included: Precision calibration standards ensure measurement accuracy to within ±0.5dB in magnitude and ±5 degrees in phase across the frequency spectrum
- Touchscreen Interface: 2.8-inch color LCD with intuitive menu system enables quick parameter selection, marker placement, and real-time data visualization without external computer dependence
- Multiple Parameter Display: Simultaneous visualization of S-parameters, impedance (Z), admittance (Y), reflection coefficient (Gamma), VSWR, and group delay in various formats including Smith Chart, polar, and rectangular plots
- USB Data Export: Native USB connectivity allows seamless transfer of measurement data to PC for advanced analysis, documentation, and archival purposes
- Rechargeable Battery: Integrated lithium battery provides 4-5 hours of field operation, eliminating dependency on AC power sources during mobile measurements
Applications and Use Cases
- Antenna Design and Tuning: Measure impedance and return loss (S11) of dipole, monopole, and patch antennas across design frequency bands to optimize matching networks and achieve target VSWR specifications
- PCB Trace Impedance Verification: Characterize transmission line impedance of high-speed digital traces, differential pairs, and RF interconnects to ensure signal integrity and compliance with design specifications
- Filter and Amplifier Characterization: Measure insertion loss (S21), group delay, and phase response of active and passive RF components to validate frequency response and identify passband ripple or stopband attenuation anomalies
- Cable and Connector Testing: Assess cable loss, connector insertion loss, and impedance discontinuities to identify defective or degraded transmission lines before field deployment
- Matching Network Design: Iteratively measure and optimize L-networks, T-networks, and stub-matching circuits to achieve conjugate impedance matching for maximum power transfer
- Component Quality Assurance: Perform incoming inspection of RF components, capacitors, inductors, and transmission lines to verify electrical characteristics and detect manufacturing defects
- Educational Laboratory Experiments: Teach RF fundamentals including S-parameters, Smith Chart interpretation, and impedance matching through hands-on measurement and visualization
How to Use
Begin by connecting the NanoVNA v2 S-A-A-2 to a power source or ensuring the battery is fully charged. Power on the device and allow the RF circuits to stabilize for approximately 30 seconds. Access the calibration menu and perform a SOLT calibration using the provided standards: connect the Short standard to Port 1, measure and confirm, then repeat with the Open and Load standards. Finally, connect the Through standard between Port 1 and Port 2 and complete the calibration. This calibration step is critical and must be repeated whenever the frequency band, cable configuration, or measurement accuracy requirements change. Store the calibration profile in device memory for future reference.
After calibration, connect your device under test (DUT) to Port 1 using a low-loss SMA cable. If measuring transmission parameters (S21), connect the output of the DUT to Port 2. Select the appropriate measurement parameter from the menu—S11 for reflection, S21 for transmission, or impedance for direct Z-parameter display. Set the frequency start and stop points to encompass your region of interest, then initiate the frequency sweep. The analyzer will display real-time data on the touchscreen with options to zoom, place markers at specific frequencies, and read precise values. For advanced analysis, export the measurement data via USB to your computer and process using network analyzer software or custom scripts. Always ensure proper impedance matching at the measurement ports and use shielded cables to minimize electromagnetic interference.
Frequently Asked Questions
What is the difference between the NanoVNA v2 S-A-A-2 and earlier NanoVNA models?
The NanoVNA v2 S-A-A-2 features extended frequency coverage beyond 3GHz (compared to 900MHz in v1), improved dynamic range exceeding 100dB, dual independent RF ports for simultaneous S-parameter measurement, and a larger 2.8-inch touchscreen display. The processor is upgraded to a dual-core ARM architecture enabling faster sweep rates and more complex calculations. Phase accuracy and calibration algorithms have been refined for superior measurement repeatability, particularly in the microwave frequency bands.
How often should I perform SOLT calibration?
SOLT calibration should be performed at the beginning of each measurement session and whenever you change the measurement frequency range, swap RF cables, or require measurement accuracy better than ±1dB. Environmental factors such as temperature fluctuations can affect calibration stability; if your laboratory temperature varies by more than 5 degrees Celsius, recalibrate to maintain accuracy. For field measurements, calibrate before and after each site visit to account for temperature and humidity variations that may affect the RF standards.
Can the NanoVNA v2 S-A-A-2 measure transmission line velocity factor and electrical length?
Yes, the NanoVNA v2 S-A-A-2 can measure transmission line characteristics by analyzing the phase shift across a known length of cable. Access the transmission line menu, input the physical length, and the analyzer calculates velocity factor and electrical length. Alternatively, use the Time Domain Reflectometry (TDR) mode if available in your firmware version to visualize impedance discontinuities and locate faults along the cable length with spatial resolution.
Is the SOLT calibration kit included, and are replacement standards available?
Yes, the SOLT calibration kit is included with the NanoVNA v2 S-A-A-2, containing precision Short, Open, Load, and Through standards rated for the full frequency range. Replacement standards are available separately from authorized distributors. Ensure standards are stored in a protective case and handled carefully to prevent mechanical damage that could degrade calibration accuracy. Periodically verify standard integrity by measuring known reference components.
When will I receive my order?
Orders are dispatched within 1-5 business days from our Bengaluru warehouse. Delivery takes 7-8 days to most locations across India.
What is your return and warranty policy?
We offer a 7-day return policy on manufacturing defects only. Contact support within 7 days of receipt for free replacement or full refund. Not applicable for user damage or misuse.
Are bulk discounts available?
Yes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.
Why Buy from The Engineer Store
- Genuine Products: Sourced directly from authorized distributors with authentication
- Expert Team: Our technical team validates every product before listing
- Fast Shipping: Dispatched within 1-5 days from our Bengaluru warehouse
- Pan-India Delivery: 7-8 days to Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata
- Payment Options: COD, UPI
Buy NanoVNA v2 S-A-A-2: 50kHz-3000MHz+ Portable Vector Network Analyzer w/ 2.8" LCD Screen & SOLT Calibration Kit Online in India
Purchase the NanoVNA v2 S-A-A-2: 50kHz-3000MHz+ Portable Vector Network Analyzer w/ 2.8" LCD Screen & SOLT Calibration Kit online at The Engineer Store, India's trusted source for genuine electronics. We deliver across Bengaluru, Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata, Ahmedabad, Jaipur, and Surat.
Our team in Bengaluru is available 24/7 to support your journey from product selection to project completion.
NanoVNA v2 S-A-A-2: 50kHz-3000MHz+ Portable Vector Network Analyzer w/ 2.8" LCD Screen & SOLT Calibration Kit
- ୟୁନିଟ୍ ମୂଲ୍ୟ
- / ପ୍ରତି
ତୁମର କାର୍ଟରେ ଉତ୍ପାଦ ଯୋଗ କରିବା |
You may also like
NanoVNA v2 S-A-A-2: 50kHz-3000MHz+ Portable Vector Network Analyzer w/ 2.8" LCD Screen & SOLT Calibration Kit
The NanoVNA v2 S-A-A-2 is a compact, high-performance portable vector network analyzer designed for RF and microwave engineers who require precise impedance, S-parameter, and transmission line measurements in field and laboratory environments. This instrument measures complex scattering parameters across a frequency range from 50kHz to 3000MHz and beyond, enabling accurate characterization of antennas, filters, amplifiers, and transmission lines without requiring bulky benchtop equipment. The included SOLT (Short-Open-Load-Through) calibration kit ensures measurement accuracy and repeatability, making it indispensable for antenna tuning, PCB trace impedance verification, component testing, and RF circuit debugging in professional and educational settings.
Product Overview
The NanoVNA v2 S-A-A-2 operates on the principle of vector network analysis, where a stimulus signal is transmitted through a device under test and the reflected and transmitted signals are measured with both magnitude and phase information. The analyzer uses a built-in RF bridge circuit and precision mixers to down-convert high-frequency signals to intermediate frequencies, which are then digitized and processed by a dual-core ARM processor. This architecture enables real-time computation of S-parameters (S11, S21, S12, S22), impedance (Z), admittance (Y), reflection coefficient (Gamma), VSWR, and group delay across the entire frequency range, all displayed on a crisp 2.8-inch color LCD touchscreen with intuitive menu navigation.
What distinguishes the NanoVNA v2 S-A-A-2 from its predecessors is its enhanced frequency coverage extending beyond 3GHz, improved dynamic range exceeding 100dB, and superior phase accuracy through advanced calibration algorithms. The instrument features two independent RF ports with SMA connectors, allowing simultaneous measurement of forward and reverse transmission characteristics. Built-in memory stores up to 100 measurement configurations and calibration profiles, while USB connectivity enables data export for post-processing in MATLAB, Excel, or custom analysis software. The rechargeable lithium battery provides 4-5 hours of continuous operation, making it ideal for field surveys, on-site antenna commissioning, and mobile network optimization tasks where AC power is unavailable.
Key Specifications
| Specification | Details |
| Product Type | Portable Vector Network Analyzer |
| Brand | NanoVNA |
| Origin | Original/Authentic |
| Warranty | 7 days on manufacturing defects |
| Shipping | 1-5 days from Bengaluru |
| Delivery | 7-8 days across India |
| Support | 24/7 via Email and WhatsApp |
| Frequency Range | 50kHz to 3000MHz+ (3GHz) |
| Display | 2.8-inch color LCD touchscreen |
| Dynamic Range | Greater than 100dB |
| Calibration Kit | SOLT (Short-Open-Load-Through) included |
| RF Connectors | SMA male connectors (dual ports) |
| Battery Life | 4-5 hours continuous operation |
Key Features
- Extended Frequency Coverage: 50kHz to 3000MHz+ enables characterization of ultra-wideband components, cellular antennas, and microwave circuits with a single instrument
- Dual Independent RF Ports: Simultaneous measurement of S11, S21, S12, and S22 parameters without port switching, reducing measurement time and improving repeatability
- High Dynamic Range: Greater than 100dB dynamic range allows detection of weak reflections and low-loss components with minimal noise floor interference
- SOLT Calibration Kit Included: Precision calibration standards ensure measurement accuracy to within ±0.5dB in magnitude and ±5 degrees in phase across the frequency spectrum
- Touchscreen Interface: 2.8-inch color LCD with intuitive menu system enables quick parameter selection, marker placement, and real-time data visualization without external computer dependence
- Multiple Parameter Display: Simultaneous visualization of S-parameters, impedance (Z), admittance (Y), reflection coefficient (Gamma), VSWR, and group delay in various formats including Smith Chart, polar, and rectangular plots
- USB Data Export: Native USB connectivity allows seamless transfer of measurement data to PC for advanced analysis, documentation, and archival purposes
- Rechargeable Battery: Integrated lithium battery provides 4-5 hours of field operation, eliminating dependency on AC power sources during mobile measurements
Applications and Use Cases
- Antenna Design and Tuning: Measure impedance and return loss (S11) of dipole, monopole, and patch antennas across design frequency bands to optimize matching networks and achieve target VSWR specifications
- PCB Trace Impedance Verification: Characterize transmission line impedance of high-speed digital traces, differential pairs, and RF interconnects to ensure signal integrity and compliance with design specifications
- Filter and Amplifier Characterization: Measure insertion loss (S21), group delay, and phase response of active and passive RF components to validate frequency response and identify passband ripple or stopband attenuation anomalies
- Cable and Connector Testing: Assess cable loss, connector insertion loss, and impedance discontinuities to identify defective or degraded transmission lines before field deployment
- Matching Network Design: Iteratively measure and optimize L-networks, T-networks, and stub-matching circuits to achieve conjugate impedance matching for maximum power transfer
- Component Quality Assurance: Perform incoming inspection of RF components, capacitors, inductors, and transmission lines to verify electrical characteristics and detect manufacturing defects
- Educational Laboratory Experiments: Teach RF fundamentals including S-parameters, Smith Chart interpretation, and impedance matching through hands-on measurement and visualization
How to Use
Begin by connecting the NanoVNA v2 S-A-A-2 to a power source or ensuring the battery is fully charged. Power on the device and allow the RF circuits to stabilize for approximately 30 seconds. Access the calibration menu and perform a SOLT calibration using the provided standards: connect the Short standard to Port 1, measure and confirm, then repeat with the Open and Load standards. Finally, connect the Through standard between Port 1 and Port 2 and complete the calibration. This calibration step is critical and must be repeated whenever the frequency band, cable configuration, or measurement accuracy requirements change. Store the calibration profile in device memory for future reference.
After calibration, connect your device under test (DUT) to Port 1 using a low-loss SMA cable. If measuring transmission parameters (S21), connect the output of the DUT to Port 2. Select the appropriate measurement parameter from the menu—S11 for reflection, S21 for transmission, or impedance for direct Z-parameter display. Set the frequency start and stop points to encompass your region of interest, then initiate the frequency sweep. The analyzer will display real-time data on the touchscreen with options to zoom, place markers at specific frequencies, and read precise values. For advanced analysis, export the measurement data via USB to your computer and process using network analyzer software or custom scripts. Always ensure proper impedance matching at the measurement ports and use shielded cables to minimize electromagnetic interference.
Frequently Asked Questions
What is the difference between the NanoVNA v2 S-A-A-2 and earlier NanoVNA models?
The NanoVNA v2 S-A-A-2 features extended frequency coverage beyond 3GHz (compared to 900MHz in v1), improved dynamic range exceeding 100dB, dual independent RF ports for simultaneous S-parameter measurement, and a larger 2.8-inch touchscreen display. The processor is upgraded to a dual-core ARM architecture enabling faster sweep rates and more complex calculations. Phase accuracy and calibration algorithms have been refined for superior measurement repeatability, particularly in the microwave frequency bands.
How often should I perform SOLT calibration?
SOLT calibration should be performed at the beginning of each measurement session and whenever you change the measurement frequency range, swap RF cables, or require measurement accuracy better than ±1dB. Environmental factors such as temperature fluctuations can affect calibration stability; if your laboratory temperature varies by more than 5 degrees Celsius, recalibrate to maintain accuracy. For field measurements, calibrate before and after each site visit to account for temperature and humidity variations that may affect the RF standards.
Can the NanoVNA v2 S-A-A-2 measure transmission line velocity factor and electrical length?
Yes, the NanoVNA v2 S-A-A-2 can measure transmission line characteristics by analyzing the phase shift across a known length of cable. Access the transmission line menu, input the physical length, and the analyzer calculates velocity factor and electrical length. Alternatively, use the Time Domain Reflectometry (TDR) mode if available in your firmware version to visualize impedance discontinuities and locate faults along the cable length with spatial resolution.
Is the SOLT calibration kit included, and are replacement standards available?
Yes, the SOLT calibration kit is included with the NanoVNA v2 S-A-A-2, containing precision Short, Open, Load, and Through standards rated for the full frequency range. Replacement standards are available separately from authorized distributors. Ensure standards are stored in a protective case and handled carefully to prevent mechanical damage that could degrade calibration accuracy. Periodically verify standard integrity by measuring known reference components.
When will I receive my order?
Orders are dispatched within 1-5 business days from our Bengaluru warehouse. Delivery takes 7-8 days to most locations across India.
What is your return and warranty policy?
We offer a 7-day return policy on manufacturing defects only. Contact support within 7 days of receipt for free replacement or full refund. Not applicable for user damage or misuse.
Are bulk discounts available?
Yes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.
Why Buy from The Engineer Store
- Genuine Products: Sourced directly from authorized distributors with authentication
- Expert Team: Our technical team validates every product before listing
- Fast Shipping: Dispatched within 1-5 days from our Bengaluru warehouse
- Pan-India Delivery: 7-8 days to Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata
- Payment Options: COD, UPI
Buy NanoVNA v2 S-A-A-2: 50kHz-3000MHz+ Portable Vector Network Analyzer w/ 2.8" LCD Screen & SOLT Calibration Kit Online in India
Purchase the NanoVNA v2 S-A-A-2: 50kHz-3000MHz+ Portable Vector Network Analyzer w/ 2.8" LCD Screen & SOLT Calibration Kit online at The Engineer Store, India's trusted source for genuine electronics. We deliver across Bengaluru, Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata, Ahmedabad, Jaipur, and Surat.
Our team in Bengaluru is available 24/7 to support your journey from product selection to project completion.
You may also like
You may also like
Recommended products
Quick service and response, product quality and packing is satisfactory.
Well built shop, not only sales but they building your. Even they conduct seminar s. You get materials at reasonable price
Very pleased with the service and hospitality. Perfect place to solve projects for engineers.I had some problems with my project , went and sat down with the guys over there . We worked on it for 4hrs and the output came . Best part was the service we received, very pleased and appreciated. Thank you so much ENGINEER STORE
Very good customer service, always ready to help. They helped us with our project for 4 hrs straight, leaving their work behind. In the end, they refused to take a single penny. Wonderful people
By completing this form, you are signing up to receive our emails and can unsubscribe at any time.
FAQ Below are some of are common questions:
Shipping charge & Delivery timeline.
1) Standard shipping: Rs 49- The order gets delivered within 3-5 working days. (6-7 days in case of the battery as it travels through the surface)
2)Free shipping is applicable to the purchase of Rs.499 and above. The order gets delivered within 5-7 working days. (8-10 days in case of the battery as it travels through the surface)
3)Blue dart Air shipping Rs: 99 and above depending on parcel weight the order gets delivered within3-5working days.
4) Same-day delivery only applicable for Pune-specific pin codes Rs-79 delivery will be done same day between 1 p.m to 9 p.m (the order should be placed before 12:30 p.m)
How do I pay for my order?
You can pay through multiple payment options on theengineerstore.in the checkout page. You can pay through Credit/Debit Card, Internet Banking, Mobile Payments, Manual bank transfer, and Wallets. You can also apply a coupon that you might receive from The Engineer store or redeem The Engineer store points that you have earned from your previous purchases.
Cash on Delivery is offered theengineerstore.in and it is location dependent. Applicability of COD is determined by our system once you enter the pin-code of your area. Also the COD service is chargeable (Rs.25). It is charged by the shipping company for cash handlings.
Once you place a COD order, our executive will call you to confirm your order only after which your order will be processed.
It is best to prepay your order and buy confidently.
You can pay through multiple payment options on theengineerstore.in the checkout page. You can pay through Credit/Debit Card, Internet Banking, Mobile Payments, Manual bank transfer, and Wallets. You can also apply a coupon that you might receive from The Engineer store or redeem The Engineer store points that you have earned from your previous purchases.
Cash on Delivery is offered theengineerstore.in and it is location dependent. Applicability of COD is determined by our system once you enter the pin-code of your area. Also the COD service is chargeable (Rs.25). It is charged by the shipping company for cash handlings.
Once you place a COD order, our executive will call you to confirm your order only after which your order will be processed.
It is best to prepay your order and buy confidently.
It is understandable that a customer will have some technical query before making any purchase on theengineerstore.in.
No worries, we are there to answer your technical queries.
What customer needs to do?Submit a ticket mentioning1. Product code/SKU--->It is found on the product page.(just on the right hand side of the product image)2. Brief description of your query.Once we receive your query, we will get back to you soon with the possible answers.
It happens sometimes, In such cases the money is neither with us nor with the bank but if we receive your money without order, we will refund it within 2-3 working days. Rest assured, the money will come back to your bank account after 10-15 working days once the payment reconciliationhappens at bank's end.
If the money still does not reflect in your bank account, contact us and we will get back to you
What customer needs to do?
Submit a ticket mentioning1. Name of the customer2. Email ID used at the time of placing order.3. Any reference number of transaction that you received from bank.