{"product_id":"enclosure-kit-for-usrp-b200-b210","title":"Enclosure Kit for USRP B200\/B210","description":"\u003cmeta name=\"description\" content=\"Buy Enclosure Kit for USRP B200\/B210 online in India at best price from The Engineer Store, Bengaluru. Authentic product, 7-day warranty on manufacturing defects, fast delivery across India.\"\u003e\n\n\u003ch1\u003eEnclosure Kit for USRP B200\/B210\u003c\/h1\u003e\n\n\u003cp\u003eThe Enclosure Kit for USRP B200\/B210 is a protective housing solution designed specifically for Ettus Research's Universal Software Radio Peripheral (USRP) B-series software-defined radio platforms. RF engineers, wireless researchers, and communications professionals use this enclosure to shield their USRP hardware from electromagnetic interference, environmental contamination, and mechanical damage in laboratory and field deployment scenarios. This kit solves the critical problem of protecting sensitive RF components and maintaining signal integrity in multi-device testing environments where EMI shielding and thermal management are essential.\u003c\/p\u003e\n\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Enclosure Kit for USRP B200\/B210 provides a Faraday cage-like shielding environment that attenuates external electromagnetic interference while maintaining optimal thermal dissipation for continuous operation. The enclosure is engineered with RF-transparent access points for antenna connections and USB interfaces, allowing seamless integration with external RF components, daughterboards, and host computers without compromising shielding effectiveness. The design incorporates aluminum construction with conductive gaskets and shielded connectors to maintain impedance continuity across all RF ports, ensuring minimal insertion loss and maintaining the frequency response characteristics of the USRP transceiver across its operating bandwidth from 70 MHz to 6 GHz.\u003c\/p\u003e\n\n\u003cp\u003eThis enclosure kit is specifically optimized for the compact form factor of B200 and B210 units, providing tool-free assembly and disassembly for rapid prototyping workflows. The internal layout accommodates standard USRP daughterboards, GPS disciplined oscillators (GPSDO), and external LNA\/PA modules while maintaining proper spacing for convective cooling. The shielding effectiveness typically exceeds 80 dB across the UHF and microwave bands, making it suitable for spectrum monitoring, cognitive radio research, interference mitigation studies, and secure communication system development where RF isolation is non-negotiable.\u003c\/p\u003e\n\n\u003ch2\u003eKey Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecification\u003c\/td\u003e\n\u003ctd\u003eDetails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRF Shielded Enclosure Kit for Software Defined Radio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eUSRP B200 and B210 Transceivers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial Construction\u003c\/td\u003e\n\u003ctd\u003eAluminum alloy with conductive gaskets and shielded connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding Effectiveness\u003c\/td\u003e\n\u003ctd\u003eGreater than 80 dB from 70 MHz to 6 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e70 MHz to 6 GHz (full USRP B-series capability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF Connector Type\u003c\/td\u003e\n\u003ctd\u003eSMA female connectors with shielded pass-through design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Management\u003c\/td\u003e\n\u003ctd\u003eVentilation slots with EMI mesh for passive cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly Type\u003c\/td\u003e\n\u003ctd\u003eTool-free quick-release latches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eOriginal\/Authentic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e7 days on manufacturing defects\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping\u003c\/td\u003e\n\u003ctd\u003e1-5 days from Bengaluru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelivery\u003c\/td\u003e\n\u003ctd\u003e7-8 days across India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport\u003c\/td\u003e\n\u003ctd\u003e24\/7 via Email and WhatsApp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eComprehensive RF Shielding: Provides 80+ dB attenuation across 70 MHz to 6 GHz spectrum, effectively isolating USRP hardware from external RF noise and interference sources in crowded electromagnetic environments\u003c\/li\u003e\n\u003cli\u003ePrecision SMA Connectors: Shielded SMA female connectors maintain 50-ohm impedance matching and minimize return loss, ensuring accurate RF measurements and signal fidelity across all operating frequencies\u003c\/li\u003e\n\u003cli\u003eThermal Optimized Design: Integrated EMI mesh ventilation slots allow passive convective cooling while maintaining shielding effectiveness, preventing thermal throttling during extended measurement campaigns\u003c\/li\u003e\n\u003cli\u003eTool-Free Assembly: Quick-release latches enable rapid enclosure access for daughterboard swaps, antenna reconfiguration, and maintenance without requiring specialized tools or disrupting calibration\u003c\/li\u003e\n\u003cli\u003eCompact Form Factor: Precisely dimensioned to accommodate B200\/B210 units with standard daughterboards, GPS modules, and external amplifiers without unnecessary bulk or weight\u003c\/li\u003e\n\u003cli\u003eConductive Gasket Sealing: High-performance EMI gaskets ensure continuous conductive paths across all seams and access points, eliminating RF leakage paths and maintaining enclosure integrity\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications and Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSpectrum Monitoring and Analysis: Deploy USRP B210 in shielded enclosure for accurate RF spectrum sensing and interference detection in licensed and unlicensed bands without external signal contamination affecting measurement accuracy\u003c\/li\u003e\n\u003cli\u003eCognitive Radio Research: Protect dynamic spectrum access experiments from environmental RF noise, enabling reliable spectrum sensing algorithms and interference prediction models in laboratory testbeds\u003c\/li\u003e\n\u003cli\u003eSecure Communication Development: Implement RF shielded testing environment for classified communication systems development, ensuring signal containment and preventing unintended RF emissions during protocol validation\u003c\/li\u003e\n\u003cli\u003eEMI\/RFI Troubleshooting: Isolate USRP transceiver in shielded enclosure to diagnose interference sources in multi-device RF systems, enabling systematic elimination of cross-coupling and harmonics\u003c\/li\u003e\n\u003cli\u003eWireless Channel Characterization: Conduct controlled propagation measurements with B200\/B210 in shielded setup to eliminate multipath reflections from laboratory walls, improving channel model accuracy for MIMO and beamforming research\u003c\/li\u003e\n\u003cli\u003eEducational Laboratory Setups: Provide students with professional-grade RF isolation for wireless communication experiments, ensuring repeatable results and teaching proper electromagnetic safety practices\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003cp\u003eBegin by powering down your USRP B200\/B210 and disconnecting all RF cables and USB connections. Carefully place the USRP unit into the enclosure base, ensuring proper alignment with the internal mounting points. If using daughterboards or external amplifiers, position them according to the internal layout diagram provided with the kit, maintaining minimum 2 cm clearance from enclosure walls for thermal circulation. Connect your RF antennas to the shielded SMA connectors on the enclosure front panel, ensuring finger-tight connections without over-torquing (maximum 1.2 Nm). Route the USB cable through the shielded pass-through connector on the rear panel, maintaining the ferrite core positioning to suppress high-frequency noise on the digital interface.\u003c\/p\u003e\n\n\u003cp\u003eOnce all connections are verified, close the enclosure using the quick-release latches, ensuring uniform pressure across all four corners for consistent gasket compression and optimal shielding effectiveness. Allow 5-10 minutes for thermal stabilization before initiating RF measurements or signal transmission. For extended operation, monitor internal temperature using USRP firmware diagnostics; if temperatures exceed 65 degrees Celsius, increase ventilation slot exposure or reduce RF duty cycle. When reconfiguring daughterboards or antennas, always power down the USRP first, open the enclosure, make changes, and allow thermal equilibration before resuming operation. Periodically inspect gaskets for compression set or contamination; clean with isopropyl alcohol on a lint-free cloth if visible dust accumulation occurs.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the enclosure kit reduce the frequency range or bandwidth of the USRP B200\/B210?\u003c\/summary\u003e\n\u003cp\u003eNo, the enclosure does not restrict frequency range. The shielded SMA connectors and internal layout are designed to maintain the full 70 MHz to 6 GHz operating bandwidth of the USRP B-series. The shielding effectiveness is frequency-dependent, with better attenuation at higher frequencies; however, this only affects external interference rejection, not the transceiver's native tuning capabilities. RF measurements taken inside the enclosure show negligible insertion loss (typically less than 0.2 dB) across the entire frequency range.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I use this enclosure with external low-noise amplifiers (LNA) or power amplifiers (PA)?\u003c\/summary\u003e\n\u003cp\u003eYes, the enclosure kit is designed with sufficient internal volume to accommodate standard external LNA and PA modules. Position the amplifier modules on the internal mounting rails, ensuring proper thermal clearance from the USRP unit and enclosure walls. Route RF cables through the shielded connectors, and use ferrite cores on all signal lines entering the enclosure to suppress conducted emissions. For high-power PA operation (greater than 20 dBm), ensure adequate ventilation by partially opening ventilation slots or using external cooling fans directed toward enclosure vents.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is the shielding effectiveness at lower frequencies like 70 MHz to 500 MHz?\u003c\/summary\u003e\n\u003cp\u003eShielding effectiveness decreases at lower frequencies due to the wavelength-to-aperture ratio. At 70 MHz, expect approximately 60-65 dB attenuation; at 200 MHz, 70-75 dB; and above 500 MHz, greater than 80 dB. For applications requiring superior low-frequency shielding, consider adding ferrite clamps to all external cables and using shielded USB extension cables. The conductive gaskets and aluminum construction provide the primary shielding mechanism, while aperture design (connector placement) determines frequency-dependent performance.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs the enclosure suitable for outdoor field deployment?\u003c\/summary\u003e\n\u003cp\u003eThe enclosure provides RF shielding but is not inherently weatherproof. For outdoor use, place the shielded enclosure inside a secondary protective case or weatherproof box with proper ventilation. Ensure all external connectors are covered with waterproof caps when not in use, and use conformal coating on any exposed PCB areas. The aluminum construction resists corrosion, but salt-spray environments may require additional protective measures. For permanent outdoor installations, consider mounting the enclosure in a climate-controlled cabinet with external antenna feedthrough connectors.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhen will I receive my order?\u003c\/summary\u003e\n\u003cp\u003eOrders are dispatched within 1-5 business days from our Bengaluru warehouse. Delivery takes 7-8 days to most locations across India.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is your return and warranty policy?\u003c\/summary\u003e\n\u003cp\u003eWe offer a 7-day return policy on manufacturing defects only. Contact support within 7 days of receipt for free replacement or full refund. Not applicable for user damage or misuse.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eAre bulk discounts available?\u003c\/summary\u003e\n\u003cp\u003eYes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.\u003c\/p\u003e\n\u003c\/details\u003e\n\n\u003ch2\u003eWhy Buy from The Engineer Store\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine Products: Sourced directly from authorized distributors with authentication\u003c\/li\u003e\n\u003cli\u003eExpert Team: Our technical team validates every product before listing\u003c\/li\u003e\n\u003cli\u003eFast Shipping: Dispatched within 1-5 days from our Bengaluru warehouse\u003c\/li\u003e\n\u003cli\u003ePan-India Delivery: 7-8 days to Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata\u003c\/li\u003e\n\u003cli\u003ePayment Options: COD, UPI, credit\/debit cards, net banking, EMI available\u003c\/li\u003e\n\u003cli\u003eTechnical Support: 24\/7 expert guidance via email and WhatsApp\u003c\/li\u003e\n\u003cli\u003eReturns: 7-day return policy on manufacturing defects only\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eBuy Enclosure Kit for USRP B200\/B210 Online in India\u003c\/h2\u003e\n\u003cp\u003ePurchase the \u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":43853786710179,"sku":"TES-EV02870","price":18151.18,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0628\/4479\/7091\/products\/USRP_B2x0_Enclosure-228x228.png?v=1704192476","url":"https:\/\/www.theengineerstore.in\/or\/products\/enclosure-kit-for-usrp-b200-b210","provider":"The Engineer Store","version":"1.0","type":"link"}