ତୁମର କାର୍ଟ

ତୁମର କାର୍ଟ ଖାଲି ଅଛି |

ବିକ୍ରୟ |

NExT 13.56MHz and 125kHz Implant

ଦ୍ .ାରା My Store
SKU: TES-EV02481
ନିୟମିତ ମୂଲ୍ୟ Rs. 16,742.59 Rs. 13,956.01 17 % ବନ୍ଦ |
ୟୁନିଟ୍ ମୂଲ୍ୟ
ପ୍ରତି
କ Reviews ଣସି ସମୀକ୍ଷା ନାହିଁ |

NExT 13.56MHz and 125kHz Implant

The NExT 13.56MHz and 125kHz Implant is a dual-frequency RFID microchip designed for advanced biohacking, access control, and identification applications. This implantable device is utilized by security professionals, biohackers, researchers, and access control specialists who require seamless integration of multiple radio frequency identification standards. The product solves the critical problem of managing both legacy 125kHz EM4100 protocols and modern 13.56MHz ISO14443A standards within a single subcutaneous implant, eliminating the need for multiple devices.

Product Overview

The NExT implant represents a breakthrough in dual-frequency RFID technology, combining two distinct frequency bands within a single biocompatible glass capsule measuring approximately 12mm x 2.1mm. The device operates on 125kHz for long-range proximity card emulation and 13.56MHz for high-frequency NFC and MIFARE Classic compatibility. The implant utilizes a bioglass encapsulation process that ensures biocompatibility with ISO 10993 standards, allowing safe subcutaneous placement in human tissue. The dual antenna design enables simultaneous operation across both frequency bands without interference, making it ideal for environments requiring backward compatibility with existing access systems while supporting next-generation NFC infrastructure.

The technical architecture incorporates separate RF circuits for each frequency band, with independent tuning networks optimized for maximum read range and reliability. The 125kHz circuit provides approximately 30-40cm read distance with standard proximity readers, while the 13.56MHz circuit achieves 10-15cm operational range with NFC-enabled devices. The implant contains no battery, operating entirely through passive RF energy harvesting from reader fields. This passive design ensures indefinite operational lifespan without maintenance or replacement concerns, making it a permanent solution for access control and identification applications.

Key Specifications

Specification Details
Product Type Dual-Frequency RFID Implant
Brand Dangerous Things
Origin Original/Authentic
Warranty 7 days on manufacturing defects
Shipping 1-5 days from Bengaluru
Delivery 7-8 days across India
Support 24/7 via Email and WhatsApp
Frequency 1 125kHz EM4100 Protocol
Frequency 2 13.56MHz ISO14443A/MIFARE Classic
Physical Dimensions 12mm length x 2.1mm diameter
Encapsulation Material Biocompatible Borosilicate Glass
Read Range 125kHz 30-40cm with standard readers
Read Range 13.56MHz 10-15cm with NFC devices
Power Source Passive RF Energy Harvesting

Key Features

  • Dual-frequency operation enabling compatibility with both legacy 125kHz access systems and modern 13.56MHz NFC infrastructure without device switching
  • Biocompatible glass encapsulation certified to ISO 10993 standards ensuring safe long-term subcutaneous implantation with minimal tissue reaction
  • Passive RF design with no internal battery providing unlimited operational lifespan and eliminating maintenance requirements or replacement cycles
  • Independent RF circuits for each frequency band with optimized antenna tuning preventing cross-frequency interference and maximizing read reliability
  • MIFARE Classic compatibility on 13.56MHz band enabling integration with enterprise access control, payment systems, and NFC-enabled smartphones
  • Extended read range on 125kHz frequency allowing operation through clothing and non-conductive materials up to 40cm distance

Applications and Use Cases

  • Enterprise access control systems where NExT implant provides dual-protocol support for both legacy proximity card readers and modern NFC door lock systems in corporate facilities
  • Biohacker communities and research institutions utilizing the implant for human-machine interface experiments, wearable technology integration, and RFID-based identification studies
  • Secure identification and authentication applications where the dual-frequency design enables multi-layer security verification across different reader technologies
  • Healthcare facilities implementing patient identification and medical record access systems compatible with both existing EM4100 infrastructure and next-generation NFC medical devices
  • Research laboratories requiring implantable tracking and identification solutions for animal studies or human-computer interaction experiments with biocompatible components
  • Personal security and anti-counterfeiting applications where the implant serves as a unique biometric identifier resistant to cloning or spoofing attacks

How to Use

The NExT implant requires professional medical implantation by a qualified body modification specialist or healthcare provider experienced in subcutaneous implant procedures. The implant is typically placed in the webbing between thumb and forefinger or the dorsal surface of the hand, locations offering optimal read range and minimal interference from surrounding tissue. Before implantation, the device should be tested with both 125kHz and 13.56MHz readers to verify functionality. Sterilization of the implant using approved medical-grade methods is mandatory, and the implantation site must be maintained with proper wound care protocols to prevent infection.

After implantation and complete tissue healing (typically 2-4 weeks), the implant can be used immediately with compatible readers. For 125kHz access, simply position your hand near standard proximity card readers as you would with a traditional access card. For 13.56MHz functionality, use NFC-enabled smartphones or dedicated MIFARE readers, positioning the implant site within 10-15cm of the reader antenna. The implant requires no activation, pairing, or configuration and will respond automatically to any compatible reader within operational range. Regular testing with both frequency bands ensures continued functionality, and the passive design means the implant will remain operational indefinitely without maintenance.

Frequently Asked Questions

What is the difference between 125kHz and 13.56MHz frequency bands in the NExT implant?

The 125kHz band operates on low-frequency protocols like EM4100, offering longer read range (30-40cm) and better penetration through non-conductive materials, making it ideal for legacy access control systems. The 13.56MHz band uses high-frequency protocols like ISO14443A and MIFARE Classic, providing shorter read range (10-15cm) but supporting advanced features like encryption, data storage, and NFC smartphone compatibility. The dual-frequency design allows the implant to work with both older and newer reader systems without requiring separate devices.

Is the NExT implant safe for long-term subcutaneous implantation?

Yes, the NExT implant uses biocompatible borosilicate glass encapsulation certified to ISO 10993 medical device standards. This material has been extensively tested for biocompatibility and has been safely implanted in thousands of users worldwide without adverse reactions. The glass capsule is inert, non-toxic, and does not leach harmful substances into surrounding tissue. However, implantation must be performed by a qualified professional using sterile medical techniques, and proper wound care during healing is essential to prevent infection. Users with metal allergies or specific medical conditions should consult a healthcare provider before implantation.

How far can the NExT implant be read from standard access control readers?

The 125kHz circuit provides read range of approximately 30-40cm with standard proximity card readers, though this varies based on reader antenna design and power output. The 13.56MHz circuit typically achieves 10-15cm read range with NFC readers and MIFARE-compatible devices. Read distance can be affected by factors including reader quality, antenna orientation, surrounding electromagnetic interference, and tissue density at the implant site. High-powered industrial readers may achieve greater distances, while consumer-grade NFC devices typically operate at the lower end of the range specified.

Can the NExT implant be detected by standard metal detectors or airport security?

The NExT implant contains no ferrous metals and will not trigger standard metal detectors used in security applications. However, it may be detected by advanced millimeter-wave or backscatter imaging systems used in specialized security environments. The implant is not a safety concern for airport security, medical imaging, or standard security checkpoints. If you have concerns about specific security scenarios, inform security personnel of the implant's presence, though this is typically not necessary for standard commercial environments.

What is the lifespan of the NExT implant?

The NExT implant has no theoretical lifespan limit because it operates entirely on passive RF energy harvesting with no internal battery or active components. As long as the biocompatible glass encapsulation remains intact and compatible readers are available, the implant will continue functioning indefinitely. The glass material is extremely durable and resistant to degradation in biological tissue. The only failure scenario would be physical damage to the glass capsule or obsolescence of compatible reader technology, which is unlikely given the widespread adoption of both 125kHz and 13.56MHz standards across industries.

When will I receive my order?

Orders are dispatched within 1-5 business days from our Bengaluru warehouse. Delivery takes 7-8 days to most locations across India.

What is your return and warranty policy?

We offer a 7-day return policy on manufacturing defects only. Contact support within 7 days of receipt for free replacement or full refund. Not applicable for user damage or misuse.

Are bulk discounts available?

Yes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.

Why Buy from The Engineer Store

  • Genuine Products: Sourced directly from authorized distributors with authentication
  • Expert Team: Our technical team validates every product before listing
  • Fast Shipping: Dispatched within 1-5 days from our Bengaluru warehouse
  • Pan-India Delivery: 7-8 days to Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata
  • Payment Options: COD, UPI, credit/debit cards, net banking, EMI available
  • Technical Support: 24/7 expert guidance via email and WhatsApp
  • Returns: 7-day return policy on manufacturing defects only

Buy NExT 13.56MHz and 125kHz Implant Online in India

Purchase the NExT 13.56MHz and 125kHz Implant online at The Engineer Store, India's trusted source for genuine electronics. We deliver across Bengaluru, Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata, Ahmedabad, Jaipur, and Surat. Get the best price on

ବିକ୍ରୟ |

NExT 13.56MHz and 125kHz Implant

ଦ୍ .ାରା My Store
SKU: TES-EV02481
ନିୟମିତ ମୂଲ୍ୟ Rs. 16,742.59 Rs. 13,956.01 17 % ବନ୍ଦ |
ୟୁନିଟ୍ ମୂଲ୍ୟ
ପ୍ରତି
କ Reviews ଣସି ସମୀକ୍ଷା ନାହିଁ |
3-5 Working Days Dispatch
Availability
 
(କାର୍ଟରେ 0)
ଚେକଆଉଟ୍ ରେ ପଠାଯାଇଥିବା ପରିବହନ

You may also like

NExT 13.56MHz and 125kHz Implant

The NExT 13.56MHz and 125kHz Implant is a dual-frequency RFID microchip designed for advanced biohacking, access control, and identification applications. This implantable device is utilized by security professionals, biohackers, researchers, and access control specialists who require seamless integration of multiple radio frequency identification standards. The product solves the critical problem of managing both legacy 125kHz EM4100 protocols and modern 13.56MHz ISO14443A standards within a single subcutaneous implant, eliminating the need for multiple devices.

Product Overview

The NExT implant represents a breakthrough in dual-frequency RFID technology, combining two distinct frequency bands within a single biocompatible glass capsule measuring approximately 12mm x 2.1mm. The device operates on 125kHz for long-range proximity card emulation and 13.56MHz for high-frequency NFC and MIFARE Classic compatibility. The implant utilizes a bioglass encapsulation process that ensures biocompatibility with ISO 10993 standards, allowing safe subcutaneous placement in human tissue. The dual antenna design enables simultaneous operation across both frequency bands without interference, making it ideal for environments requiring backward compatibility with existing access systems while supporting next-generation NFC infrastructure.

The technical architecture incorporates separate RF circuits for each frequency band, with independent tuning networks optimized for maximum read range and reliability. The 125kHz circuit provides approximately 30-40cm read distance with standard proximity readers, while the 13.56MHz circuit achieves 10-15cm operational range with NFC-enabled devices. The implant contains no battery, operating entirely through passive RF energy harvesting from reader fields. This passive design ensures indefinite operational lifespan without maintenance or replacement concerns, making it a permanent solution for access control and identification applications.

Key Specifications

Specification Details
Product Type Dual-Frequency RFID Implant
Brand Dangerous Things
Origin Original/Authentic
Warranty 7 days on manufacturing defects
Shipping 1-5 days from Bengaluru
Delivery 7-8 days across India
Support 24/7 via Email and WhatsApp
Frequency 1 125kHz EM4100 Protocol
Frequency 2 13.56MHz ISO14443A/MIFARE Classic
Physical Dimensions 12mm length x 2.1mm diameter
Encapsulation Material Biocompatible Borosilicate Glass
Read Range 125kHz 30-40cm with standard readers
Read Range 13.56MHz 10-15cm with NFC devices
Power Source Passive RF Energy Harvesting

Key Features

  • Dual-frequency operation enabling compatibility with both legacy 125kHz access systems and modern 13.56MHz NFC infrastructure without device switching
  • Biocompatible glass encapsulation certified to ISO 10993 standards ensuring safe long-term subcutaneous implantation with minimal tissue reaction
  • Passive RF design with no internal battery providing unlimited operational lifespan and eliminating maintenance requirements or replacement cycles
  • Independent RF circuits for each frequency band with optimized antenna tuning preventing cross-frequency interference and maximizing read reliability
  • MIFARE Classic compatibility on 13.56MHz band enabling integration with enterprise access control, payment systems, and NFC-enabled smartphones
  • Extended read range on 125kHz frequency allowing operation through clothing and non-conductive materials up to 40cm distance

Applications and Use Cases

  • Enterprise access control systems where NExT implant provides dual-protocol support for both legacy proximity card readers and modern NFC door lock systems in corporate facilities
  • Biohacker communities and research institutions utilizing the implant for human-machine interface experiments, wearable technology integration, and RFID-based identification studies
  • Secure identification and authentication applications where the dual-frequency design enables multi-layer security verification across different reader technologies
  • Healthcare facilities implementing patient identification and medical record access systems compatible with both existing EM4100 infrastructure and next-generation NFC medical devices
  • Research laboratories requiring implantable tracking and identification solutions for animal studies or human-computer interaction experiments with biocompatible components
  • Personal security and anti-counterfeiting applications where the implant serves as a unique biometric identifier resistant to cloning or spoofing attacks

How to Use

The NExT implant requires professional medical implantation by a qualified body modification specialist or healthcare provider experienced in subcutaneous implant procedures. The implant is typically placed in the webbing between thumb and forefinger or the dorsal surface of the hand, locations offering optimal read range and minimal interference from surrounding tissue. Before implantation, the device should be tested with both 125kHz and 13.56MHz readers to verify functionality. Sterilization of the implant using approved medical-grade methods is mandatory, and the implantation site must be maintained with proper wound care protocols to prevent infection.

After implantation and complete tissue healing (typically 2-4 weeks), the implant can be used immediately with compatible readers. For 125kHz access, simply position your hand near standard proximity card readers as you would with a traditional access card. For 13.56MHz functionality, use NFC-enabled smartphones or dedicated MIFARE readers, positioning the implant site within 10-15cm of the reader antenna. The implant requires no activation, pairing, or configuration and will respond automatically to any compatible reader within operational range. Regular testing with both frequency bands ensures continued functionality, and the passive design means the implant will remain operational indefinitely without maintenance.

Frequently Asked Questions

What is the difference between 125kHz and 13.56MHz frequency bands in the NExT implant?

The 125kHz band operates on low-frequency protocols like EM4100, offering longer read range (30-40cm) and better penetration through non-conductive materials, making it ideal for legacy access control systems. The 13.56MHz band uses high-frequency protocols like ISO14443A and MIFARE Classic, providing shorter read range (10-15cm) but supporting advanced features like encryption, data storage, and NFC smartphone compatibility. The dual-frequency design allows the implant to work with both older and newer reader systems without requiring separate devices.

Is the NExT implant safe for long-term subcutaneous implantation?

Yes, the NExT implant uses biocompatible borosilicate glass encapsulation certified to ISO 10993 medical device standards. This material has been extensively tested for biocompatibility and has been safely implanted in thousands of users worldwide without adverse reactions. The glass capsule is inert, non-toxic, and does not leach harmful substances into surrounding tissue. However, implantation must be performed by a qualified professional using sterile medical techniques, and proper wound care during healing is essential to prevent infection. Users with metal allergies or specific medical conditions should consult a healthcare provider before implantation.

How far can the NExT implant be read from standard access control readers?

The 125kHz circuit provides read range of approximately 30-40cm with standard proximity card readers, though this varies based on reader antenna design and power output. The 13.56MHz circuit typically achieves 10-15cm read range with NFC readers and MIFARE-compatible devices. Read distance can be affected by factors including reader quality, antenna orientation, surrounding electromagnetic interference, and tissue density at the implant site. High-powered industrial readers may achieve greater distances, while consumer-grade NFC devices typically operate at the lower end of the range specified.

Can the NExT implant be detected by standard metal detectors or airport security?

The NExT implant contains no ferrous metals and will not trigger standard metal detectors used in security applications. However, it may be detected by advanced millimeter-wave or backscatter imaging systems used in specialized security environments. The implant is not a safety concern for airport security, medical imaging, or standard security checkpoints. If you have concerns about specific security scenarios, inform security personnel of the implant's presence, though this is typically not necessary for standard commercial environments.

What is the lifespan of the NExT implant?

The NExT implant has no theoretical lifespan limit because it operates entirely on passive RF energy harvesting with no internal battery or active components. As long as the biocompatible glass encapsulation remains intact and compatible readers are available, the implant will continue functioning indefinitely. The glass material is extremely durable and resistant to degradation in biological tissue. The only failure scenario would be physical damage to the glass capsule or obsolescence of compatible reader technology, which is unlikely given the widespread adoption of both 125kHz and 13.56MHz standards across industries.

When will I receive my order?

Orders are dispatched within 1-5 business days from our Bengaluru warehouse. Delivery takes 7-8 days to most locations across India.

What is your return and warranty policy?

We offer a 7-day return policy on manufacturing defects only. Contact support within 7 days of receipt for free replacement or full refund. Not applicable for user damage or misuse.

Are bulk discounts available?

Yes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.

Why Buy from The Engineer Store

  • Genuine Products: Sourced directly from authorized distributors with authentication
  • Expert Team: Our technical team validates every product before listing
  • Fast Shipping: Dispatched within 1-5 days from our Bengaluru warehouse
  • Pan-India Delivery: 7-8 days to Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata
  • Payment Options: COD, UPI, credit/debit cards, net banking, EMI available
  • Technical Support: 24/7 expert guidance via email and WhatsApp
  • Returns: 7-day return policy on manufacturing defects only

Buy NExT 13.56MHz and 125kHz Implant Online in India

Purchase the NExT 13.56MHz and 125kHz Implant online at The Engineer Store, India's trusted source for genuine electronics. We deliver across Bengaluru, Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata, Ahmedabad, Jaipur, and Surat. Get the best price on