Real Time C101+
- ୟୁନିଟ୍ ମୂଲ୍ୟ
- / ପ୍ରତି
Real Time C101+
The Real Time C101+ is a precision digital multimeter designed for professional electrical testing and troubleshooting in industrial and field applications. Electrical engineers, technicians, and maintenance professionals rely on this instrument to measure voltage, current, resistance, and continuity with high accuracy across AC and DC circuits. This meter solves the critical problem of quick fault diagnosis and circuit validation in live electrical environments where speed and accuracy are non-negotiable.
Product Overview
The Real Time C101+ operates on the principle of digital signal conversion, utilizing a high-resolution analog-to-digital converter to translate electrical parameters into precise numerical readings on its LCD display. The device features automatic range selection technology that eliminates manual switching between measurement ranges, reducing operator error and increasing measurement speed. The internal circuitry incorporates overload protection mechanisms that safeguard the instrument against voltage spikes and transient surges, making it suitable for harsh industrial environments where power quality is unpredictable.
What distinguishes the C101+ model is its robust construction with dual CAT III safety rating, allowing safe operation on both low-voltage control circuits and higher-voltage distribution systems. The meter integrates a true RMS measurement capability for AC voltage and current, ensuring accurate readings even when measuring non-sinusoidal waveforms common in variable frequency drives and switching power supplies. The ergonomic design with rubberized grip and intuitive button layout enables single-handed operation, while the backlit display ensures visibility in dimly lit electrical rooms and underground installations.
Key Specifications
| Specification | Details |
| Product Type | Digital Multimeter - Professional Grade |
| Brand | Real Time |
| Origin | Original/Authentic |
| Warranty | 7 days on manufacturing defects |
| Shipping | 1-5 days from Bengaluru |
| Delivery | 7-8 days across India |
| Support | 24/7 via Email and WhatsApp |
| DC Voltage Range | 200mV to 1000V with 0.5% accuracy |
| AC Voltage Range | 200V to 750V True RMS with 1% accuracy |
| DC Current Range | 200µA to 20A with 1.2% accuracy |
| Resistance Measurement | 200Ω to 20MΩ with automatic range selection |
| Display Type | 3.5 digit LCD with backlight and auto-off feature |
| Safety Rating | CAT III 1000V / CAT IV 600V dual rated |
Key Features
- True RMS measurement technology ensures accurate readings on distorted AC waveforms from variable frequency drives and non-linear loads
- Automatic range selection eliminates manual switching and reduces measurement time during troubleshooting procedures
- Overload protection circuit with fused inputs prevents permanent damage from accidental high-voltage exposure
- Dual CAT rating (CAT III 1000V / CAT IV 600V) enables safe testing in both industrial distribution and control circuit environments
- Data hold function captures and freezes readings for documentation and comparison during diagnostic procedures
- Continuity buzzer with visual indicator provides rapid feedback for circuit tracing and connection verification
Applications and Use Cases
- Industrial maintenance: Testing motor windings, control circuits, and power distribution systems in manufacturing facilities where downtime is costly
- Electrical installation verification: Validating proper wiring polarity, grounding continuity, and voltage presence before energizing new circuits
- HVAC troubleshooting: Measuring thermostat signals, contactor coil voltages, and compressor motor currents in commercial refrigeration systems
- Building automation diagnostics: Testing sensor inputs, relay outputs, and communication signals in building management system networks
- Field service calls: Rapid voltage and continuity checks in residential and commercial electrical panels to identify fault locations
How to Use
Begin by selecting your measurement type using the rotary dial on the front panel, positioning it toward DC voltage, AC voltage, current, resistance, or continuity as required. Insert the black probe into the COM (common) terminal and the red probe into the appropriate input terminal based on your measurement range - use the mA terminal for currents up to 200mA, or the 20A terminal for higher currents. Always ensure the meter is set to the correct measurement type before connecting probes to the circuit, and never attempt to measure current by connecting the meter in parallel across a component.
For voltage measurements, connect the probes across the component or between the point of interest and ground, keeping probes steady until the display stabilizes. The automatic range selection will adjust the measurement scale, but you can manually select a specific range by rotating the dial to a fixed position if you prefer. For resistance and continuity measurements, ensure the circuit is de-energized and isolated from power sources to prevent damage to the meter and ensure accurate readings. Always remove the probes from the circuit immediately after measurement is complete, and store the meter in a dry location away from extreme temperatures to maintain calibration accuracy.
Frequently Asked Questions
What does True RMS measurement mean and why is it important?
True RMS (Root Mean Square) measures the actual heating effect of an AC waveform, making it essential for non-sinusoidal signals. Unlike average-reading meters that assume pure sine waves, the C101+ calculates the true effective value of distorted waveforms from variable frequency drives, LED dimmers, and switching power supplies. This ensures accurate current and voltage readings in modern industrial environments where harmonic distortion is common.
Can I measure current without breaking the circuit?
No, current measurement requires the meter to be connected in series with the circuit, meaning you must break the circuit connection and insert the meter probes. Never attempt to measure current by connecting the meter in parallel, as this will create a short circuit and damage the meter's internal fuse. Always turn off power before connecting for current measurement, then turn power back on only after the meter is properly connected in series.
What is the difference between CAT III and CAT IV safety ratings?
CAT ratings indicate the meter's ability to withstand transient overvoltages. CAT IV 600V is for utility supply connections and outdoor installations where lightning surges are possible. CAT III 1000V is for industrial distribution systems and fixed installations. The C101+ dual rating means it can safely measure at 1000V in distribution systems but only up to 600V in outdoor utility environments. Always respect these limits as exceeding them risks arc flash and equipment damage.
When will I receive my order?
Orders are dispatched within 1-5 business days from our Bengaluru warehouse. Delivery takes 7-8 days to most locations across India.
What is your return and warranty policy?
We offer a 7-day return policy on manufacturing defects only. Contact support within 7 days of receipt for free replacement or full refund. Not applicable for user damage or misuse.
Are bulk discounts available?
Yes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.
Why Buy from The Engineer Store
- Genuine Products: Sourced directly from authorized distributors with authentication
- Expert Team: Our technical team validates every product before listing
- Fast Shipping: Dispatched within 1-5 days from our Bengaluru warehouse
- Pan-India Delivery: 7-8 days to Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata
- Payment Options: COD, UPI, credit/debit cards, net banking, EMI available
- Technical Support: 24/7 expert guidance via email and WhatsApp
- Returns: 7-day return policy on manufacturing defects only
Buy Real Time C101+ Online in India
Purchase the Real Time C101+ online at The Engineer Store, India's trusted source for genuine electronics. We deliver across Bengaluru, Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata, Ahmedabad, Jaipur, and Surat. Get the best price on Real Time C101+ with fast shipping and expert support.
Our team in Bengaluru is available 24/7 to support your journey from product selection to project completion.
Real Time C101+
- ୟୁନିଟ୍ ମୂଲ୍ୟ
- / ପ୍ରତି
ତୁମର କାର୍ଟରେ ଉତ୍ପାଦ ଯୋଗ କରିବା |
You may also like
Real Time C101+
The Real Time C101+ is a precision digital multimeter designed for professional electrical testing and troubleshooting in industrial and field applications. Electrical engineers, technicians, and maintenance professionals rely on this instrument to measure voltage, current, resistance, and continuity with high accuracy across AC and DC circuits. This meter solves the critical problem of quick fault diagnosis and circuit validation in live electrical environments where speed and accuracy are non-negotiable.
Product Overview
The Real Time C101+ operates on the principle of digital signal conversion, utilizing a high-resolution analog-to-digital converter to translate electrical parameters into precise numerical readings on its LCD display. The device features automatic range selection technology that eliminates manual switching between measurement ranges, reducing operator error and increasing measurement speed. The internal circuitry incorporates overload protection mechanisms that safeguard the instrument against voltage spikes and transient surges, making it suitable for harsh industrial environments where power quality is unpredictable.
What distinguishes the C101+ model is its robust construction with dual CAT III safety rating, allowing safe operation on both low-voltage control circuits and higher-voltage distribution systems. The meter integrates a true RMS measurement capability for AC voltage and current, ensuring accurate readings even when measuring non-sinusoidal waveforms common in variable frequency drives and switching power supplies. The ergonomic design with rubberized grip and intuitive button layout enables single-handed operation, while the backlit display ensures visibility in dimly lit electrical rooms and underground installations.
Key Specifications
| Specification | Details |
| Product Type | Digital Multimeter - Professional Grade |
| Brand | Real Time |
| Origin | Original/Authentic |
| Warranty | 7 days on manufacturing defects |
| Shipping | 1-5 days from Bengaluru |
| Delivery | 7-8 days across India |
| Support | 24/7 via Email and WhatsApp |
| DC Voltage Range | 200mV to 1000V with 0.5% accuracy |
| AC Voltage Range | 200V to 750V True RMS with 1% accuracy |
| DC Current Range | 200µA to 20A with 1.2% accuracy |
| Resistance Measurement | 200Ω to 20MΩ with automatic range selection |
| Display Type | 3.5 digit LCD with backlight and auto-off feature |
| Safety Rating | CAT III 1000V / CAT IV 600V dual rated |
Key Features
- True RMS measurement technology ensures accurate readings on distorted AC waveforms from variable frequency drives and non-linear loads
- Automatic range selection eliminates manual switching and reduces measurement time during troubleshooting procedures
- Overload protection circuit with fused inputs prevents permanent damage from accidental high-voltage exposure
- Dual CAT rating (CAT III 1000V / CAT IV 600V) enables safe testing in both industrial distribution and control circuit environments
- Data hold function captures and freezes readings for documentation and comparison during diagnostic procedures
- Continuity buzzer with visual indicator provides rapid feedback for circuit tracing and connection verification
Applications and Use Cases
- Industrial maintenance: Testing motor windings, control circuits, and power distribution systems in manufacturing facilities where downtime is costly
- Electrical installation verification: Validating proper wiring polarity, grounding continuity, and voltage presence before energizing new circuits
- HVAC troubleshooting: Measuring thermostat signals, contactor coil voltages, and compressor motor currents in commercial refrigeration systems
- Building automation diagnostics: Testing sensor inputs, relay outputs, and communication signals in building management system networks
- Field service calls: Rapid voltage and continuity checks in residential and commercial electrical panels to identify fault locations
How to Use
Begin by selecting your measurement type using the rotary dial on the front panel, positioning it toward DC voltage, AC voltage, current, resistance, or continuity as required. Insert the black probe into the COM (common) terminal and the red probe into the appropriate input terminal based on your measurement range - use the mA terminal for currents up to 200mA, or the 20A terminal for higher currents. Always ensure the meter is set to the correct measurement type before connecting probes to the circuit, and never attempt to measure current by connecting the meter in parallel across a component.
For voltage measurements, connect the probes across the component or between the point of interest and ground, keeping probes steady until the display stabilizes. The automatic range selection will adjust the measurement scale, but you can manually select a specific range by rotating the dial to a fixed position if you prefer. For resistance and continuity measurements, ensure the circuit is de-energized and isolated from power sources to prevent damage to the meter and ensure accurate readings. Always remove the probes from the circuit immediately after measurement is complete, and store the meter in a dry location away from extreme temperatures to maintain calibration accuracy.
Frequently Asked Questions
What does True RMS measurement mean and why is it important?
True RMS (Root Mean Square) measures the actual heating effect of an AC waveform, making it essential for non-sinusoidal signals. Unlike average-reading meters that assume pure sine waves, the C101+ calculates the true effective value of distorted waveforms from variable frequency drives, LED dimmers, and switching power supplies. This ensures accurate current and voltage readings in modern industrial environments where harmonic distortion is common.
Can I measure current without breaking the circuit?
No, current measurement requires the meter to be connected in series with the circuit, meaning you must break the circuit connection and insert the meter probes. Never attempt to measure current by connecting the meter in parallel, as this will create a short circuit and damage the meter's internal fuse. Always turn off power before connecting for current measurement, then turn power back on only after the meter is properly connected in series.
What is the difference between CAT III and CAT IV safety ratings?
CAT ratings indicate the meter's ability to withstand transient overvoltages. CAT IV 600V is for utility supply connections and outdoor installations where lightning surges are possible. CAT III 1000V is for industrial distribution systems and fixed installations. The C101+ dual rating means it can safely measure at 1000V in distribution systems but only up to 600V in outdoor utility environments. Always respect these limits as exceeding them risks arc flash and equipment damage.
When will I receive my order?
Orders are dispatched within 1-5 business days from our Bengaluru warehouse. Delivery takes 7-8 days to most locations across India.
What is your return and warranty policy?
We offer a 7-day return policy on manufacturing defects only. Contact support within 7 days of receipt for free replacement or full refund. Not applicable for user damage or misuse.
Are bulk discounts available?
Yes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.
Why Buy from The Engineer Store
- Genuine Products: Sourced directly from authorized distributors with authentication
- Expert Team: Our technical team validates every product before listing
- Fast Shipping: Dispatched within 1-5 days from our Bengaluru warehouse
- Pan-India Delivery: 7-8 days to Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata
- Payment Options: COD, UPI, credit/debit cards, net banking, EMI available
- Technical Support: 24/7 expert guidance via email and WhatsApp
- Returns: 7-day return policy on manufacturing defects only
Buy Real Time C101+ Online in India
Purchase the Real Time C101+ online at The Engineer Store, India's trusted source for genuine electronics. We deliver across Bengaluru, Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata, Ahmedabad, Jaipur, and Surat. Get the best price on Real Time C101+ with fast shipping and expert support.
Our team in Bengaluru is available 24/7 to support your journey from product selection to project completion.
You may also like
You may also like
Recommended products
Quick service and response, product quality and packing is satisfactory.
Well built shop, not only sales but they building your. Even they conduct seminar s. You get materials at reasonable price
Very pleased with the service and hospitality. Perfect place to solve projects for engineers.I had some problems with my project , went and sat down with the guys over there . We worked on it for 4hrs and the output came . Best part was the service we received, very pleased and appreciated. Thank you so much ENGINEER STORE
Very good customer service, always ready to help. They helped us with our project for 4 hrs straight, leaving their work behind. In the end, they refused to take a single penny. Wonderful people
By completing this form, you are signing up to receive our emails and can unsubscribe at any time.
FAQ Below are some of are common questions:
Shipping charge & Delivery timeline.
1) Standard shipping: Rs 49- The order gets delivered within 3-5 working days. (6-7 days in case of the battery as it travels through the surface)
2)Free shipping is applicable to the purchase of Rs.499 and above. The order gets delivered within 5-7 working days. (8-10 days in case of the battery as it travels through the surface)
3)Blue dart Air shipping Rs: 99 and above depending on parcel weight the order gets delivered within3-5working days.
4) Same-day delivery only applicable for Pune-specific pin codes Rs-79 delivery will be done same day between 1 p.m to 9 p.m (the order should be placed before 12:30 p.m)
How do I pay for my order?
You can pay through multiple payment options on theengineerstore.in the checkout page. You can pay through Credit/Debit Card, Internet Banking, Mobile Payments, Manual bank transfer, and Wallets. You can also apply a coupon that you might receive from The Engineer store or redeem The Engineer store points that you have earned from your previous purchases.
Cash on Delivery is offered theengineerstore.in and it is location dependent. Applicability of COD is determined by our system once you enter the pin-code of your area. Also the COD service is chargeable (Rs.25). It is charged by the shipping company for cash handlings.
Once you place a COD order, our executive will call you to confirm your order only after which your order will be processed.
It is best to prepay your order and buy confidently.
You can pay through multiple payment options on theengineerstore.in the checkout page. You can pay through Credit/Debit Card, Internet Banking, Mobile Payments, Manual bank transfer, and Wallets. You can also apply a coupon that you might receive from The Engineer store or redeem The Engineer store points that you have earned from your previous purchases.
Cash on Delivery is offered theengineerstore.in and it is location dependent. Applicability of COD is determined by our system once you enter the pin-code of your area. Also the COD service is chargeable (Rs.25). It is charged by the shipping company for cash handlings.
Once you place a COD order, our executive will call you to confirm your order only after which your order will be processed.
It is best to prepay your order and buy confidently.
It is understandable that a customer will have some technical query before making any purchase on theengineerstore.in.
No worries, we are there to answer your technical queries.
What customer needs to do?Submit a ticket mentioning1. Product code/SKU--->It is found on the product page.(just on the right hand side of the product image)2. Brief description of your query.Once we receive your query, we will get back to you soon with the possible answers.
It happens sometimes, In such cases the money is neither with us nor with the bank but if we receive your money without order, we will refund it within 2-3 working days. Rest assured, the money will come back to your bank account after 10-15 working days once the payment reconciliationhappens at bank's end.
If the money still does not reflect in your bank account, contact us and we will get back to you
What customer needs to do?
Submit a ticket mentioning1. Name of the customer2. Email ID used at the time of placing order.3. Any reference number of transaction that you received from bank.