BioNic M8 V2
- அலகு விலை
- / ஒன்றுக்கு
BioNic M8 V2
The BioNic M8 V2 is a precision biomechatronic control module designed for advanced robotic prosthetics and exoskeleton systems, featuring real-time neural signal processing and adaptive motor control. Professional biomedical engineers, prosthetics specialists, and robotics researchers utilize this device to create intelligent limb systems that respond dynamically to user intent through electromyography (EMG) signal interpretation. This product solves the critical challenge of translating biological signals into smooth, natural motion control while maintaining low latency response times essential for seamless user experience in assistive and augmentative devices.
Product Overview
The BioNic M8 V2 operates on a sophisticated multi-channel EMG acquisition and processing architecture, capturing electrical signals from residual muscles with 16-bit resolution at sampling rates up to 2000 Hz per channel. The device employs advanced digital signal processing algorithms including wavelet decomposition and machine learning-based pattern recognition to filter noise, eliminate motion artifacts, and accurately classify user intent within 50-100 milliseconds. The V2 iteration introduces improved analog-to-digital converters with reduced input-referred noise (less than 5 microvolts RMS), enhanced wireless stability through dual-band connectivity, and optimized power management extending operational battery life to 18 hours of continuous use.
What distinguishes the M8 V2 from competing solutions is its modular architecture supporting up to 8 independent motor control channels with individual PID tuning capabilities, allowing simultaneous control of multiple joint actuators with programmable coordination algorithms. The integrated IMU (Inertial Measurement Unit) with 9-axis sensing provides real-time feedback on limb position and acceleration, enabling closed-loop control systems that automatically adjust motor output based on actual movement versus intended movement. This feedback mechanism creates natural compliance and prevents jerky movements, while the onboard microcontroller runs custom firmware that developers can reprogram for specific prosthetic or exoskeleton applications.
Key Specifications
| Specification | Details |
| Product Type | Biomechatronic Control Module |
| Brand | BioNic |
| Origin | Original/Authentic |
| Warranty | 7 days on manufacturing defects |
| Shipping | 1-5 days from Bengaluru |
| Delivery | 7-8 days across India |
| Support | 24/7 via Email and WhatsApp |
| EMG Channels | 8 independent acquisition channels |
| Motor Control Outputs | 8 independent PWM channels, 0-24V, 5A per channel |
| Sampling Rate | 2000 Hz per channel, 16-bit ADC resolution |
| Input Noise Floor | Less than 5 microvolts RMS |
| Processing Latency | 50-100 milliseconds signal-to-output |
| Battery Life | 18 hours continuous operation |
| Wireless Connectivity | Dual-band WiFi and Bluetooth 5.0 |
| IMU Sensors | 9-axis (3-axis accelerometer, gyroscope, magnetometer) |
Key Features
- 8-Channel EMG Acquisition with 16-bit precision and 2000 Hz sampling rate for accurate muscle signal capture and real-time neural decoding
- 8 Independent Motor Control Channels with individual PID tuning, PWM modulation, and current limiting to prevent actuator damage
- Advanced Digital Signal Processing including wavelet decomposition, noise filtering, and machine learning-based gesture recognition
- Integrated 9-Axis IMU providing real-time proprioceptive feedback for closed-loop control and natural movement coordination
- Dual-Band Wireless Connectivity with WiFi and Bluetooth 5.0 for remote monitoring, calibration, and firmware updates
- Programmable Microcontroller with open-source firmware support for custom algorithm development and application-specific tuning
- Extended Battery Life of 18 hours with intelligent power management and low-power sleep modes
- Modular Design enabling scalable configurations from single-joint to multi-joint prosthetic and exoskeleton systems
Applications and Use Cases
- Advanced Prosthetic Limbs for upper and lower extremity amputees requiring multi-degree-of-freedom control with natural movement patterns and real-time sensory feedback integration
- Robotic Exoskeletons for rehabilitation therapy, industrial worker augmentation, and mobility assistance in elderly care applications with coordinated multi-joint actuation
- Biomedical Research Platforms for studying human-machine interfaces, motor control mechanisms, and neural plasticity in academic and clinical research settings
- Assistive Technology Devices for individuals with neuromuscular disorders requiring EMG-based control interfaces for communication aids and environmental control systems
How to Use
Begin setup by mounting the BioNic M8 V2 control module in a secure enclosure near the prosthetic or exoskeleton actuators, ensuring proper ventilation for thermal management. Connect the 8 EMG electrode leads to the corresponding input channels, positioning electrodes on target muscles with proper skin preparation using conductive gel and securing with adhesive patches. Calibrate the system by running the provided calibration software, which guides users through controlled muscle contractions to establish baseline signals and set individual channel thresholds. Connect motor outputs to your actuators, configuring voltage and current limits based on motor specifications, then program the control algorithm through the web-based interface or directly via the microcontroller using provided C/C++ libraries.
During operation, monitor real-time signal quality through the dashboard to ensure proper electrode contact and minimal noise. The system automatically applies digital filtering and artifact rejection, but optimal performance requires stable electrode placement and consistent skin impedance. For advanced applications, utilize the onboard IMU feedback to implement closed-loop control algorithms that adjust motor output based on actual limb position versus intended position, creating natural compliance and preventing overshoot. Regularly update firmware through the wireless interface to access performance improvements and new feature releases from the development community.
Frequently Asked Questions
What is the maximum latency from EMG signal to motor output?
The BioNic M8 V2 achieves 50-100 milliseconds total latency from initial EMG signal acquisition through digital processing to motor command output. This latency is optimized for natural prosthetic control where users perceive movement as responsive to their intent. The latency includes analog-to-digital conversion (500 microseconds), digital signal processing (30-50 milliseconds), and motor driver response (20 milliseconds). Advanced users can reduce latency further by optimizing their control algorithms and reducing filtering window sizes, though this may increase noise sensitivity.
Can I use the M8 V2 with wireless control for remote operation?
Yes, the dual-band WiFi and Bluetooth 5.0 connectivity enables wireless monitoring and control, though real-time prosthetic operation requires wired EMG electrode connections for safety and reliability. Wireless capability is primarily designed for remote calibration, firmware updates, data logging, and parameter adjustment. For autonomous prosthetic operation, the onboard microcontroller operates independently without requiring wireless connectivity, ensuring the device functions reliably even if wireless connection drops. This architecture prioritizes user safety by maintaining continuous local control without dependency on network connectivity.
How many different gestures or movements can the system recognize?
The BioNic M8 V2 can recognize up to 20-30 distinct muscle contraction patterns depending on the number of EMG channels used and the complexity of your training dataset. The machine learning engine supports custom pattern training where users perform specific muscle contraction sequences that the system learns and maps to desired motor outputs. Recognition accuracy typically exceeds 95% after proper calibration and training. Advanced implementations using all 8 channels with coordinated multi-muscle patterns can achieve even higher gesture complexity, enabling natural control of prosthetics with multiple degrees of freedom.
When will I receive my order?
Orders are dispatched within 1-5 business days from our Bengaluru warehouse. Delivery takes 7-8 days to most locations across India.
What is your return and warranty policy?
We offer a 7-day return policy on manufacturing defects only. Contact support within 7 days of receipt for free replacement or full refund. Not applicable for user damage or misuse.
Are bulk discounts available?
Yes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.
Why Buy from The Engineer Store
- Genuine Products: Sourced directly from authorized distributors with authentication
- Expert Team: Our technical team validates every product before listing
- Fast Shipping: Dispatched within 1-5 days from our Bengaluru warehouse
- Pan-India Delivery: 7-8 days to Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata
- Payment Options: COD, UPI, credit/debit cards, net banking, EMI available
- Technical Support: 24/7 expert guidance via email and WhatsApp
- Returns: 7-day return policy on manufacturing defects only
Buy BioNic M8 V2 Online in India
Purchase the BioNic M8 V2 online at The Engineer Store, India's trusted source for genuine electronics. We deliver across Bengaluru, Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata, Ahmedabad, Jaipur, and Surat. Get the best price on BioNic M8 V2 with fast shipping and expert support.
Our team in Bengaluru is available 24/7 to support your journey from product selection to project completion.
BioNic M8 V2
- அலகு விலை
- / ஒன்றுக்கு
உங்கள் வண்டியில் தயாரிப்பு சேர்க்கிறது
நீயும் விரும்புவாய்
BioNic M8 V2
The BioNic M8 V2 is a precision biomechatronic control module designed for advanced robotic prosthetics and exoskeleton systems, featuring real-time neural signal processing and adaptive motor control. Professional biomedical engineers, prosthetics specialists, and robotics researchers utilize this device to create intelligent limb systems that respond dynamically to user intent through electromyography (EMG) signal interpretation. This product solves the critical challenge of translating biological signals into smooth, natural motion control while maintaining low latency response times essential for seamless user experience in assistive and augmentative devices.
Product Overview
The BioNic M8 V2 operates on a sophisticated multi-channel EMG acquisition and processing architecture, capturing electrical signals from residual muscles with 16-bit resolution at sampling rates up to 2000 Hz per channel. The device employs advanced digital signal processing algorithms including wavelet decomposition and machine learning-based pattern recognition to filter noise, eliminate motion artifacts, and accurately classify user intent within 50-100 milliseconds. The V2 iteration introduces improved analog-to-digital converters with reduced input-referred noise (less than 5 microvolts RMS), enhanced wireless stability through dual-band connectivity, and optimized power management extending operational battery life to 18 hours of continuous use.
What distinguishes the M8 V2 from competing solutions is its modular architecture supporting up to 8 independent motor control channels with individual PID tuning capabilities, allowing simultaneous control of multiple joint actuators with programmable coordination algorithms. The integrated IMU (Inertial Measurement Unit) with 9-axis sensing provides real-time feedback on limb position and acceleration, enabling closed-loop control systems that automatically adjust motor output based on actual movement versus intended movement. This feedback mechanism creates natural compliance and prevents jerky movements, while the onboard microcontroller runs custom firmware that developers can reprogram for specific prosthetic or exoskeleton applications.
Key Specifications
| Specification | Details |
| Product Type | Biomechatronic Control Module |
| Brand | BioNic |
| Origin | Original/Authentic |
| Warranty | 7 days on manufacturing defects |
| Shipping | 1-5 days from Bengaluru |
| Delivery | 7-8 days across India |
| Support | 24/7 via Email and WhatsApp |
| EMG Channels | 8 independent acquisition channels |
| Motor Control Outputs | 8 independent PWM channels, 0-24V, 5A per channel |
| Sampling Rate | 2000 Hz per channel, 16-bit ADC resolution |
| Input Noise Floor | Less than 5 microvolts RMS |
| Processing Latency | 50-100 milliseconds signal-to-output |
| Battery Life | 18 hours continuous operation |
| Wireless Connectivity | Dual-band WiFi and Bluetooth 5.0 |
| IMU Sensors | 9-axis (3-axis accelerometer, gyroscope, magnetometer) |
Key Features
- 8-Channel EMG Acquisition with 16-bit precision and 2000 Hz sampling rate for accurate muscle signal capture and real-time neural decoding
- 8 Independent Motor Control Channels with individual PID tuning, PWM modulation, and current limiting to prevent actuator damage
- Advanced Digital Signal Processing including wavelet decomposition, noise filtering, and machine learning-based gesture recognition
- Integrated 9-Axis IMU providing real-time proprioceptive feedback for closed-loop control and natural movement coordination
- Dual-Band Wireless Connectivity with WiFi and Bluetooth 5.0 for remote monitoring, calibration, and firmware updates
- Programmable Microcontroller with open-source firmware support for custom algorithm development and application-specific tuning
- Extended Battery Life of 18 hours with intelligent power management and low-power sleep modes
- Modular Design enabling scalable configurations from single-joint to multi-joint prosthetic and exoskeleton systems
Applications and Use Cases
- Advanced Prosthetic Limbs for upper and lower extremity amputees requiring multi-degree-of-freedom control with natural movement patterns and real-time sensory feedback integration
- Robotic Exoskeletons for rehabilitation therapy, industrial worker augmentation, and mobility assistance in elderly care applications with coordinated multi-joint actuation
- Biomedical Research Platforms for studying human-machine interfaces, motor control mechanisms, and neural plasticity in academic and clinical research settings
- Assistive Technology Devices for individuals with neuromuscular disorders requiring EMG-based control interfaces for communication aids and environmental control systems
How to Use
Begin setup by mounting the BioNic M8 V2 control module in a secure enclosure near the prosthetic or exoskeleton actuators, ensuring proper ventilation for thermal management. Connect the 8 EMG electrode leads to the corresponding input channels, positioning electrodes on target muscles with proper skin preparation using conductive gel and securing with adhesive patches. Calibrate the system by running the provided calibration software, which guides users through controlled muscle contractions to establish baseline signals and set individual channel thresholds. Connect motor outputs to your actuators, configuring voltage and current limits based on motor specifications, then program the control algorithm through the web-based interface or directly via the microcontroller using provided C/C++ libraries.
During operation, monitor real-time signal quality through the dashboard to ensure proper electrode contact and minimal noise. The system automatically applies digital filtering and artifact rejection, but optimal performance requires stable electrode placement and consistent skin impedance. For advanced applications, utilize the onboard IMU feedback to implement closed-loop control algorithms that adjust motor output based on actual limb position versus intended position, creating natural compliance and preventing overshoot. Regularly update firmware through the wireless interface to access performance improvements and new feature releases from the development community.
Frequently Asked Questions
What is the maximum latency from EMG signal to motor output?
The BioNic M8 V2 achieves 50-100 milliseconds total latency from initial EMG signal acquisition through digital processing to motor command output. This latency is optimized for natural prosthetic control where users perceive movement as responsive to their intent. The latency includes analog-to-digital conversion (500 microseconds), digital signal processing (30-50 milliseconds), and motor driver response (20 milliseconds). Advanced users can reduce latency further by optimizing their control algorithms and reducing filtering window sizes, though this may increase noise sensitivity.
Can I use the M8 V2 with wireless control for remote operation?
Yes, the dual-band WiFi and Bluetooth 5.0 connectivity enables wireless monitoring and control, though real-time prosthetic operation requires wired EMG electrode connections for safety and reliability. Wireless capability is primarily designed for remote calibration, firmware updates, data logging, and parameter adjustment. For autonomous prosthetic operation, the onboard microcontroller operates independently without requiring wireless connectivity, ensuring the device functions reliably even if wireless connection drops. This architecture prioritizes user safety by maintaining continuous local control without dependency on network connectivity.
How many different gestures or movements can the system recognize?
The BioNic M8 V2 can recognize up to 20-30 distinct muscle contraction patterns depending on the number of EMG channels used and the complexity of your training dataset. The machine learning engine supports custom pattern training where users perform specific muscle contraction sequences that the system learns and maps to desired motor outputs. Recognition accuracy typically exceeds 95% after proper calibration and training. Advanced implementations using all 8 channels with coordinated multi-muscle patterns can achieve even higher gesture complexity, enabling natural control of prosthetics with multiple degrees of freedom.
When will I receive my order?
Orders are dispatched within 1-5 business days from our Bengaluru warehouse. Delivery takes 7-8 days to most locations across India.
What is your return and warranty policy?
We offer a 7-day return policy on manufacturing defects only. Contact support within 7 days of receipt for free replacement or full refund. Not applicable for user damage or misuse.
Are bulk discounts available?
Yes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.
Why Buy from The Engineer Store
- Genuine Products: Sourced directly from authorized distributors with authentication
- Expert Team: Our technical team validates every product before listing
- Fast Shipping: Dispatched within 1-5 days from our Bengaluru warehouse
- Pan-India Delivery: 7-8 days to Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata
- Payment Options: COD, UPI, credit/debit cards, net banking, EMI available
- Technical Support: 24/7 expert guidance via email and WhatsApp
- Returns: 7-day return policy on manufacturing defects only
Buy BioNic M8 V2 Online in India
Purchase the BioNic M8 V2 online at The Engineer Store, India's trusted source for genuine electronics. We deliver across Bengaluru, Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata, Ahmedabad, Jaipur, and Surat. Get the best price on BioNic M8 V2 with fast shipping and expert support.
Our team in Bengaluru is available 24/7 to support your journey from product selection to project completion.
நீயும் விரும்புவாய்
நீயும் விரும்புவாய்
பரிந்துரைக்கப்பட்ட தயாரிப்புகள்
விரைவான சேவை மற்றும் பதில், தயாரிப்பு தரம் மற்றும் பேக்கிங் திருப்திகரமாக உள்ளது.
நன்கு கட்டப்பட்ட கடை, விற்பனை மட்டுமல்ல, அவை உங்கள் கட்டிடத்தையும் உருவாக்குகின்றன. கூட அவர்கள் கருத்தரங்கு நடத்துகிறார் கள். நியாயமான விலையில் பொருட்கள் கிடைக்கும்
சேவை மற்றும் விருந்தோம்பலில் மிகவும் மகிழ்ச்சி. பொறியாளர்களுக்கான திட்டங்களைத் தீர்க்க சரியான இடம். எனது திட்டத்தில் சில சிக்கல்கள் இருந்தன, அங்குள்ள தோழர்களுடன் சென்று அமர்ந்தேன். நாங்கள் 4 மணிநேரம் வேலை செய்தோம், வெளியீடு வந்தது. சிறந்த பகுதியாக நாங்கள் பெற்ற சேவை, மிகவும் மகிழ்ச்சி மற்றும் பாராட்டப்பட்டது. மிக்க நன்றி இன்ஜினியர் ஸ்டோர்
மிகவும் நல்ல வாடிக்கையாளர் சேவை, எப்போதும் உதவ தயாராக உள்ளது. அவர்கள் தொடர்ந்து 4 மணிநேரம் எங்கள் திட்டத்தில் எங்களுக்கு உதவினார்கள், தங்கள் வேலையை விட்டுவிட்டார்கள். கடைசியில் ஒரு பைசா கூட வாங்க மறுத்துவிட்டனர். அற்புதமான மனிதர்கள்
இந்தப் படிவத்தைப் பூர்த்தி செய்வதன் மூலம், எங்களின் மின்னஞ்சல்களைப் பெற நீங்கள் பதிவு செய்கிறீர்கள் மேலும் எந்த நேரத்திலும் குழுவிலகலாம்.
FAQ Below are some of are common questions:
Shipping charge & Delivery timeline.
1) Standard shipping: Rs 49- The order gets delivered within 3-5 working days. (6-7 days in case of the battery as it travels through the surface)
2)Free shipping is applicable to the purchase of Rs.499 and above. The order gets delivered within 5-7 working days. (8-10 days in case of the battery as it travels through the surface)
3)Blue dart Air shipping Rs: 99 and above depending on parcel weight the order gets delivered within3-5working days.
4) Same-day delivery only applicable for Pune-specific pin codes Rs-79 delivery will be done same day between 1 p.m to 9 p.m (the order should be placed before 12:30 p.m)
How do I pay for my order?
You can pay through multiple payment options on theengineerstore.in the checkout page. You can pay through Credit/Debit Card, Internet Banking, Mobile Payments, Manual bank transfer, and Wallets. You can also apply a coupon that you might receive from The Engineer store or redeem The Engineer store points that you have earned from your previous purchases.
Cash on Delivery is offered theengineerstore.in and it is location dependent. Applicability of COD is determined by our system once you enter the pin-code of your area. Also the COD service is chargeable (Rs.25). It is charged by the shipping company for cash handlings.
Once you place a COD order, our executive will call you to confirm your order only after which your order will be processed.
It is best to prepay your order and buy confidently.
You can pay through multiple payment options on theengineerstore.in the checkout page. You can pay through Credit/Debit Card, Internet Banking, Mobile Payments, Manual bank transfer, and Wallets. You can also apply a coupon that you might receive from The Engineer store or redeem The Engineer store points that you have earned from your previous purchases.
Cash on Delivery is offered theengineerstore.in and it is location dependent. Applicability of COD is determined by our system once you enter the pin-code of your area. Also the COD service is chargeable (Rs.25). It is charged by the shipping company for cash handlings.
Once you place a COD order, our executive will call you to confirm your order only after which your order will be processed.
It is best to prepay your order and buy confidently.
It is understandable that a customer will have some technical query before making any purchase on theengineerstore.in.
No worries, we are there to answer your technical queries.
What customer needs to do?Submit a ticket mentioning1. Product code/SKU--->It is found on the product page.(just on the right hand side of the product image)2. Brief description of your query.Once we receive your query, we will get back to you soon with the possible answers.
It happens sometimes, In such cases the money is neither with us nor with the bank but if we receive your money without order, we will refund it within 2-3 working days. Rest assured, the money will come back to your bank account after 10-15 working days once the payment reconciliationhappens at bank's end.
If the money still does not reflect in your bank account, contact us and we will get back to you
What customer needs to do?
Submit a ticket mentioning1. Name of the customer2. Email ID used at the time of placing order.3. Any reference number of transaction that you received from bank.