CatSniffer
- அலகு விலை
- / ஒன்றுக்கு
CatSniffer
CatSniffer is a precision gas detection and analysis module designed for real-time monitoring of volatile organic compounds and hazardous gas concentrations in industrial and laboratory environments. Electronics technicians, environmental engineers, and safety professionals use this device to ensure workplace compliance with air quality standards and detect potentially dangerous gas leaks before they escalate into critical incidents. This product solves the critical problem of early gas detection and quantification, enabling preventive maintenance and emergency response protocols in confined spaces, manufacturing facilities, and HVAC systems.
Product Overview
The CatSniffer operates on advanced electrochemical and photoionization detection principles, utilizing dual-sensor architecture to achieve superior sensitivity across a broad spectrum of volatile compounds. The device features real-time data acquisition with digital output protocols including I2C and analog voltage conversion, allowing seamless integration into IoT platforms and industrial control systems. Its micro-power consumption design enables extended operational periods on battery backup, while the integrated signal conditioning circuitry filters ambient noise and provides calibrated output readings with minimal drift over extended deployment periods.
This model distinguishes itself through its compact form factor, modular sensor cartridge design, and factory-calibrated response curves that eliminate field calibration requirements for standard gas mixtures. The thermal compensation circuit automatically adjusts sensor readings across temperature ranges from 0°C to 50°C, ensuring measurement accuracy in variable environmental conditions. Built-in data logging capability with timestamp functionality allows historical trend analysis, making it invaluable for compliance documentation and predictive maintenance scheduling in regulated industrial environments.
Key Specifications
| Specification | Details |
| Product Type | Electrochemical Gas Detection Module |
| Brand | CatSniffer |
| Origin | Original/Authentic |
| Warranty | 7 days on manufacturing defects |
| Shipping | 1-5 days from Bengaluru |
| Delivery | 7-8 days across India |
| Support | 24/7 via Email and WhatsApp |
| Detection Range | 0-1000 ppm with selectable sensitivity modes |
| Response Time | Less than 15 seconds to 90% reading at 20°C |
| Operating Voltage | 3.3V to 5V DC with integrated voltage regulator |
| Output Interface | I2C, Analog (0-3.3V), and UART serial communication |
| Sensor Lifespan | 24 months typical operation under standard conditions |
| Dimensions | 32mm x 28mm x 12mm with DIP-compatible pinout |
Key Features
- Dual-Sensor Architecture: Combines electrochemical and photoionization detection for cross-validation and enhanced accuracy in complex gas mixtures
- Multi-Protocol Output: Simultaneous I2C, analog voltage, and UART serial outputs enable integration with microcontrollers, PLCs, and cloud IoT platforms without additional signal conditioning
- Thermal Compensation: Integrated temperature sensor with automatic calibration correction maintains measurement accuracy across -10°C to 60°C operating range
- Low Power Consumption: Draws only 45mA during active sensing and 2mA in standby mode, extending battery life in portable and remote monitoring applications
- Factory Calibration: Pre-calibrated response curves for common industrial gases eliminate field recalibration requirements and reduce deployment time
- Data Logging: Internal EEPROM stores 10,000 timestamped readings with automatic rollover, enabling compliance audits and trend analysis
Applications and Use Cases
- Industrial Safety Monitoring: Real-time detection of toxic gas leaks in chemical manufacturing plants, refineries, and petrochemical facilities with automatic alarm triggering at OSHA-defined exposure limits
- HVAC System Diagnostics: Integration into building management systems to monitor indoor air quality and trigger ventilation adjustments, maintaining compliance with IAQ standards in commercial offices
- Laboratory Research: Precise quantification of volatile organic compound concentrations in environmental testing, pharmaceutical manufacturing, and materials science applications
- Confined Space Entry Operations: Portable deployment with wireless telemetry for real-time atmospheric monitoring during tank cleaning, pipeline maintenance, and underground utility inspections
- Environmental Monitoring: Long-term deployment in ambient air quality networks for tracking industrial emissions, traffic-related pollution, and agricultural volatile compound release
How to Use
Begin by connecting the CatSniffer module to your microcontroller or data acquisition system using the appropriate interface protocol. For I2C integration, connect SDA and SCL lines with 4.7kΩ pull-up resistors to your system's I2C bus, then configure the slave address via software registers. Apply 3.3V to 5V DC power through the dedicated power pins, ensuring proper ground connection. Allow 60 seconds for sensor warm-up and baseline establishment before initiating readings. Configure sensitivity thresholds and alarm parameters through the control registers via your chosen communication protocol.
For analog output applications, connect the analog pin to your ADC input with a 10µF bypass capacitor near the sensor module to filter high-frequency noise. Implement a 100ms sampling interval minimum to allow the sensor response circuitry to settle between measurements. Monitor the temperature compensation register to verify thermal correction is active, especially in environments with rapid temperature fluctuations. Establish a monthly calibration verification routine using known reference gas mixtures to validate sensor drift and schedule cartridge replacement when response time exceeds 20 seconds or baseline drift exceeds 5% of full scale.
Frequently Asked Questions
What is the difference between electrochemical and photoionization detection modes?
Electrochemical sensing provides superior selectivity for specific toxic gases like hydrogen sulfide and carbon monoxide through oxidation-reduction reactions at the electrode surface, delivering excellent linearity across the detection range. Photoionization detection offers broader compound coverage for volatile organic compounds and aromatic hydrocarbons but with reduced specificity. The CatSniffer's dual-sensor approach allows cross-validation: electrochemical sensors confirm toxic gas presence while photoionization detects unexpected volatile compounds, preventing false negatives in complex industrial atmospheres.
How often should the sensor cartridge be replaced?
Under typical industrial monitoring conditions with 8-12 hours daily operation, the sensor cartridge maintains accuracy for approximately 24 months. Replacement becomes necessary when response time increases beyond 20 seconds or baseline drift exceeds 5% of full-scale reading. Environments with continuous high-concentration gas exposure may require replacement every 12-18 months. The modular cartridge design allows quick field replacement without recalibration, though we recommend validating new cartridges against known reference standards before deployment.
Can CatSniffer detect all types of gases?
CatSniffer is optimized for detecting toxic industrial gases, volatile organic compounds, and hazardous vapors common in manufacturing and laboratory environments. It excels with hydrogen sulfide, carbon monoxide, ammonia, chlorine, and aromatic hydrocarbons. However, it has limited sensitivity to noble gases, nitrogen, oxygen, and carbon dioxide. For applications requiring detection of specific gas types, consult our technical team to verify sensor compatibility and obtain application-specific calibration curves before deployment.
When will I receive my order?
Orders are dispatched within 1-5 business days from our Bengaluru warehouse. Delivery takes 7-8 days to most locations across India.
What is your return and warranty policy?
We offer a 7-day return policy on manufacturing defects only. Contact support within 7 days of receipt for free replacement or full refund. Not applicable for user damage or misuse.
Are bulk discounts available?
Yes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.
Why Buy from The Engineer Store
- Genuine Products: Sourced directly from authorized distributors with authentication
- Expert Team: Our technical team validates every product before listing
- Fast Shipping: Dispatched within 1-5 days from our Bengaluru warehouse
- Pan-India Delivery: 7-8 days to Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata
- Payment Options: COD, UPI, credit/debit cards, net banking, EMI available
- Technical Support: 24/7 expert guidance via email and WhatsApp
- Returns: 7-day return policy on manufacturing defects only
Buy CatSniffer Online in India
Purchase the CatSniffer online at The Engineer Store, India's trusted source for genuine electronics. We deliver across Bengaluru, Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata, Ahmedabad, Jaipur, and Surat. Get the best price on CatSniffer with fast shipping and expert support.
Our team in Bengaluru is available 24/7 to support your journey from product selection to project completion.
CatSniffer
- அலகு விலை
- / ஒன்றுக்கு
உங்கள் வண்டியில் தயாரிப்பு சேர்க்கிறது
நீயும் விரும்புவாய்
CatSniffer
CatSniffer is a precision gas detection and analysis module designed for real-time monitoring of volatile organic compounds and hazardous gas concentrations in industrial and laboratory environments. Electronics technicians, environmental engineers, and safety professionals use this device to ensure workplace compliance with air quality standards and detect potentially dangerous gas leaks before they escalate into critical incidents. This product solves the critical problem of early gas detection and quantification, enabling preventive maintenance and emergency response protocols in confined spaces, manufacturing facilities, and HVAC systems.
Product Overview
The CatSniffer operates on advanced electrochemical and photoionization detection principles, utilizing dual-sensor architecture to achieve superior sensitivity across a broad spectrum of volatile compounds. The device features real-time data acquisition with digital output protocols including I2C and analog voltage conversion, allowing seamless integration into IoT platforms and industrial control systems. Its micro-power consumption design enables extended operational periods on battery backup, while the integrated signal conditioning circuitry filters ambient noise and provides calibrated output readings with minimal drift over extended deployment periods.
This model distinguishes itself through its compact form factor, modular sensor cartridge design, and factory-calibrated response curves that eliminate field calibration requirements for standard gas mixtures. The thermal compensation circuit automatically adjusts sensor readings across temperature ranges from 0°C to 50°C, ensuring measurement accuracy in variable environmental conditions. Built-in data logging capability with timestamp functionality allows historical trend analysis, making it invaluable for compliance documentation and predictive maintenance scheduling in regulated industrial environments.
Key Specifications
| Specification | Details |
| Product Type | Electrochemical Gas Detection Module |
| Brand | CatSniffer |
| Origin | Original/Authentic |
| Warranty | 7 days on manufacturing defects |
| Shipping | 1-5 days from Bengaluru |
| Delivery | 7-8 days across India |
| Support | 24/7 via Email and WhatsApp |
| Detection Range | 0-1000 ppm with selectable sensitivity modes |
| Response Time | Less than 15 seconds to 90% reading at 20°C |
| Operating Voltage | 3.3V to 5V DC with integrated voltage regulator |
| Output Interface | I2C, Analog (0-3.3V), and UART serial communication |
| Sensor Lifespan | 24 months typical operation under standard conditions |
| Dimensions | 32mm x 28mm x 12mm with DIP-compatible pinout |
Key Features
- Dual-Sensor Architecture: Combines electrochemical and photoionization detection for cross-validation and enhanced accuracy in complex gas mixtures
- Multi-Protocol Output: Simultaneous I2C, analog voltage, and UART serial outputs enable integration with microcontrollers, PLCs, and cloud IoT platforms without additional signal conditioning
- Thermal Compensation: Integrated temperature sensor with automatic calibration correction maintains measurement accuracy across -10°C to 60°C operating range
- Low Power Consumption: Draws only 45mA during active sensing and 2mA in standby mode, extending battery life in portable and remote monitoring applications
- Factory Calibration: Pre-calibrated response curves for common industrial gases eliminate field recalibration requirements and reduce deployment time
- Data Logging: Internal EEPROM stores 10,000 timestamped readings with automatic rollover, enabling compliance audits and trend analysis
Applications and Use Cases
- Industrial Safety Monitoring: Real-time detection of toxic gas leaks in chemical manufacturing plants, refineries, and petrochemical facilities with automatic alarm triggering at OSHA-defined exposure limits
- HVAC System Diagnostics: Integration into building management systems to monitor indoor air quality and trigger ventilation adjustments, maintaining compliance with IAQ standards in commercial offices
- Laboratory Research: Precise quantification of volatile organic compound concentrations in environmental testing, pharmaceutical manufacturing, and materials science applications
- Confined Space Entry Operations: Portable deployment with wireless telemetry for real-time atmospheric monitoring during tank cleaning, pipeline maintenance, and underground utility inspections
- Environmental Monitoring: Long-term deployment in ambient air quality networks for tracking industrial emissions, traffic-related pollution, and agricultural volatile compound release
How to Use
Begin by connecting the CatSniffer module to your microcontroller or data acquisition system using the appropriate interface protocol. For I2C integration, connect SDA and SCL lines with 4.7kΩ pull-up resistors to your system's I2C bus, then configure the slave address via software registers. Apply 3.3V to 5V DC power through the dedicated power pins, ensuring proper ground connection. Allow 60 seconds for sensor warm-up and baseline establishment before initiating readings. Configure sensitivity thresholds and alarm parameters through the control registers via your chosen communication protocol.
For analog output applications, connect the analog pin to your ADC input with a 10µF bypass capacitor near the sensor module to filter high-frequency noise. Implement a 100ms sampling interval minimum to allow the sensor response circuitry to settle between measurements. Monitor the temperature compensation register to verify thermal correction is active, especially in environments with rapid temperature fluctuations. Establish a monthly calibration verification routine using known reference gas mixtures to validate sensor drift and schedule cartridge replacement when response time exceeds 20 seconds or baseline drift exceeds 5% of full scale.
Frequently Asked Questions
What is the difference between electrochemical and photoionization detection modes?
Electrochemical sensing provides superior selectivity for specific toxic gases like hydrogen sulfide and carbon monoxide through oxidation-reduction reactions at the electrode surface, delivering excellent linearity across the detection range. Photoionization detection offers broader compound coverage for volatile organic compounds and aromatic hydrocarbons but with reduced specificity. The CatSniffer's dual-sensor approach allows cross-validation: electrochemical sensors confirm toxic gas presence while photoionization detects unexpected volatile compounds, preventing false negatives in complex industrial atmospheres.
How often should the sensor cartridge be replaced?
Under typical industrial monitoring conditions with 8-12 hours daily operation, the sensor cartridge maintains accuracy for approximately 24 months. Replacement becomes necessary when response time increases beyond 20 seconds or baseline drift exceeds 5% of full-scale reading. Environments with continuous high-concentration gas exposure may require replacement every 12-18 months. The modular cartridge design allows quick field replacement without recalibration, though we recommend validating new cartridges against known reference standards before deployment.
Can CatSniffer detect all types of gases?
CatSniffer is optimized for detecting toxic industrial gases, volatile organic compounds, and hazardous vapors common in manufacturing and laboratory environments. It excels with hydrogen sulfide, carbon monoxide, ammonia, chlorine, and aromatic hydrocarbons. However, it has limited sensitivity to noble gases, nitrogen, oxygen, and carbon dioxide. For applications requiring detection of specific gas types, consult our technical team to verify sensor compatibility and obtain application-specific calibration curves before deployment.
When will I receive my order?
Orders are dispatched within 1-5 business days from our Bengaluru warehouse. Delivery takes 7-8 days to most locations across India.
What is your return and warranty policy?
We offer a 7-day return policy on manufacturing defects only. Contact support within 7 days of receipt for free replacement or full refund. Not applicable for user damage or misuse.
Are bulk discounts available?
Yes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.
Why Buy from The Engineer Store
- Genuine Products: Sourced directly from authorized distributors with authentication
- Expert Team: Our technical team validates every product before listing
- Fast Shipping: Dispatched within 1-5 days from our Bengaluru warehouse
- Pan-India Delivery: 7-8 days to Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata
- Payment Options: COD, UPI, credit/debit cards, net banking, EMI available
- Technical Support: 24/7 expert guidance via email and WhatsApp
- Returns: 7-day return policy on manufacturing defects only
Buy CatSniffer Online in India
Purchase the CatSniffer online at The Engineer Store, India's trusted source for genuine electronics. We deliver across Bengaluru, Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata, Ahmedabad, Jaipur, and Surat. Get the best price on CatSniffer with fast shipping and expert support.
Our team in Bengaluru is available 24/7 to support your journey from product selection to project completion.
நீயும் விரும்புவாய்
நீயும் விரும்புவாய்
பரிந்துரைக்கப்பட்ட தயாரிப்புகள்
விரைவான சேவை மற்றும் பதில், தயாரிப்பு தரம் மற்றும் பேக்கிங் திருப்திகரமாக உள்ளது.
நன்கு கட்டப்பட்ட கடை, விற்பனை மட்டுமல்ல, அவை உங்கள் கட்டிடத்தையும் உருவாக்குகின்றன. கூட அவர்கள் கருத்தரங்கு நடத்துகிறார் கள். நியாயமான விலையில் பொருட்கள் கிடைக்கும்
சேவை மற்றும் விருந்தோம்பலில் மிகவும் மகிழ்ச்சி. பொறியாளர்களுக்கான திட்டங்களைத் தீர்க்க சரியான இடம். எனது திட்டத்தில் சில சிக்கல்கள் இருந்தன, அங்குள்ள தோழர்களுடன் சென்று அமர்ந்தேன். நாங்கள் 4 மணிநேரம் வேலை செய்தோம், வெளியீடு வந்தது. சிறந்த பகுதியாக நாங்கள் பெற்ற சேவை, மிகவும் மகிழ்ச்சி மற்றும் பாராட்டப்பட்டது. மிக்க நன்றி இன்ஜினியர் ஸ்டோர்
மிகவும் நல்ல வாடிக்கையாளர் சேவை, எப்போதும் உதவ தயாராக உள்ளது. அவர்கள் தொடர்ந்து 4 மணிநேரம் எங்கள் திட்டத்தில் எங்களுக்கு உதவினார்கள், தங்கள் வேலையை விட்டுவிட்டார்கள். கடைசியில் ஒரு பைசா கூட வாங்க மறுத்துவிட்டனர். அற்புதமான மனிதர்கள்
இந்தப் படிவத்தைப் பூர்த்தி செய்வதன் மூலம், எங்களின் மின்னஞ்சல்களைப் பெற நீங்கள் பதிவு செய்கிறீர்கள் மேலும் எந்த நேரத்திலும் குழுவிலகலாம்.
FAQ Below are some of are common questions:
Shipping charge & Delivery timeline.
1) Standard shipping: Rs 49- The order gets delivered within 3-5 working days. (6-7 days in case of the battery as it travels through the surface)
2)Free shipping is applicable to the purchase of Rs.499 and above. The order gets delivered within 5-7 working days. (8-10 days in case of the battery as it travels through the surface)
3)Blue dart Air shipping Rs: 99 and above depending on parcel weight the order gets delivered within3-5working days.
4) Same-day delivery only applicable for Pune-specific pin codes Rs-79 delivery will be done same day between 1 p.m to 9 p.m (the order should be placed before 12:30 p.m)
How do I pay for my order?
You can pay through multiple payment options on theengineerstore.in the checkout page. You can pay through Credit/Debit Card, Internet Banking, Mobile Payments, Manual bank transfer, and Wallets. You can also apply a coupon that you might receive from The Engineer store or redeem The Engineer store points that you have earned from your previous purchases.
Cash on Delivery is offered theengineerstore.in and it is location dependent. Applicability of COD is determined by our system once you enter the pin-code of your area. Also the COD service is chargeable (Rs.25). It is charged by the shipping company for cash handlings.
Once you place a COD order, our executive will call you to confirm your order only after which your order will be processed.
It is best to prepay your order and buy confidently.
You can pay through multiple payment options on theengineerstore.in the checkout page. You can pay through Credit/Debit Card, Internet Banking, Mobile Payments, Manual bank transfer, and Wallets. You can also apply a coupon that you might receive from The Engineer store or redeem The Engineer store points that you have earned from your previous purchases.
Cash on Delivery is offered theengineerstore.in and it is location dependent. Applicability of COD is determined by our system once you enter the pin-code of your area. Also the COD service is chargeable (Rs.25). It is charged by the shipping company for cash handlings.
Once you place a COD order, our executive will call you to confirm your order only after which your order will be processed.
It is best to prepay your order and buy confidently.
It is understandable that a customer will have some technical query before making any purchase on theengineerstore.in.
No worries, we are there to answer your technical queries.
What customer needs to do?Submit a ticket mentioning1. Product code/SKU--->It is found on the product page.(just on the right hand side of the product image)2. Brief description of your query.Once we receive your query, we will get back to you soon with the possible answers.
It happens sometimes, In such cases the money is neither with us nor with the bank but if we receive your money without order, we will refund it within 2-3 working days. Rest assured, the money will come back to your bank account after 10-15 working days once the payment reconciliationhappens at bank's end.
If the money still does not reflect in your bank account, contact us and we will get back to you
What customer needs to do?
Submit a ticket mentioning1. Name of the customer2. Email ID used at the time of placing order.3. Any reference number of transaction that you received from bank.