{"product_id":"gw-instek-lcr-916-handheld-lcr-meter","title":"GW Instek LCR 916 Handheld LCR Meter","description":"\u003cmeta name=\"description\" content=\"Buy GW Instek LCR 916 Handheld LCR Meter online in India at best price from The Engineer Store, Bengaluru. Authentic product, 7-day warranty on manufacturing defects, fast delivery across India.\"\u003e\n\n\u003ch1\u003eGW Instek LCR 916 Handheld LCR Meter\u003c\/h1\u003e\n\n\u003cp\u003eThe GW Instek LCR 916 is a portable handheld LCR meter designed for precise measurement of inductance, capacitance, and resistance across multiple frequency ranges from 100 Hz to 10 kHz. Electronics engineers, PCB designers, and field technicians use this instrument to verify component specifications, troubleshoot circuit failures, and validate component quality during manufacturing and repair operations. It solves the critical problem of accurate impedance characterization without requiring bulky benchtop equipment, enabling rapid in-field diagnostics and quality assurance testing.\u003c\/p\u003e\n\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe GW Instek LCR 916 operates on the principle of AC bridge measurement, applying a known AC signal across the component under test and measuring the resulting impedance parameters. The meter displays inductance (L), capacitance (C), resistance (R), and derived parameters including quality factor (Q), dissipation factor (D), and impedance (Z) with exceptional accuracy. Its dual-display capability allows simultaneous viewing of primary and secondary parameters, while the 4-digit LCD screen provides clear readability in both laboratory and field environments. The instrument features automatic range selection to minimize user error and includes test lead compensation for high-precision measurements even with extended probe cables.\u003c\/p\u003e\n\n\u003cp\u003eWhat distinguishes the LCR 916 is its combination of measurement speed, frequency flexibility, and practical handheld form factor. Operating at four selectable frequencies (100 Hz, 120 Hz, 1 kHz, and 10 kHz), it accommodates diverse testing requirements from low-frequency power supply components to high-frequency signal path inductors. The meter incorporates a 0.5 percent basic accuracy specification for capacitance and inductance measurements, meeting industrial quality standards. Built-in test lead open and short compensation functions eliminate systematic errors, while the rugged polycarbonate housing and integrated test leads make it suitable for workshop, production floor, and field service applications.\u003c\/p\u003e\n\n\u003ch2\u003eKey Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecification\u003c\/td\u003e\n\u003ctd\u003eDetails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHandheld LCR Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGW Instek\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eOriginal\/Authentic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e7 days on manufacturing defects\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping\u003c\/td\u003e\n\u003ctd\u003e1-5 days from Bengaluru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelivery\u003c\/td\u003e\n\u003ctd\u003e7-8 days across India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport\u003c\/td\u003e\n\u003ctd\u003e24\/7 via Email and WhatsApp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Frequencies\u003c\/td\u003e\n\u003ctd\u003e100 Hz, 120 Hz, 1 kHz, 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInductance Range\u003c\/td\u003e\n\u003ctd\u003e0.001 uH to 9999 H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Range\u003c\/td\u003e\n\u003ctd\u003e0.001 pF to 9999 uF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Range\u003c\/td\u003e\n\u003ctd\u003e0.01 ohm to 9999 kohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.5 percent for L and C measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e4-digit LCD with dual parameter display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Signal Level\u003c\/td\u003e\n\u003ctd\u003e0.3V or 1V selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e2x AA batteries (approximately 30 hours operation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-frequency operation at 100 Hz, 120 Hz, 1 kHz, and 10 kHz enables testing of components across audio, power, and RF frequency ranges with appropriate impedance characterization\u003c\/li\u003e\n\u003cli\u003eDual-parameter simultaneous display shows primary measurement (L, C, or R) alongside secondary parameters (Q, D, Z, or ESR) for comprehensive component analysis without menu navigation\u003c\/li\u003e\n\u003cli\u003eAutomatic range selection eliminates manual range switching and reduces measurement errors caused by incorrect scale selection during field testing\u003c\/li\u003e\n\u003cli\u003eTest lead compensation function removes systematic errors introduced by probe resistance and capacitance, ensuring measurement accuracy even with extended or worn test leads\u003c\/li\u003e\n\u003cli\u003eSelectable test signal levels (0.3V and 1V) accommodate both standard components and sensitive devices requiring low-voltage testing\u003c\/li\u003e\n\u003cli\u003eCompact handheld design with integrated test leads provides portability for on-site troubleshooting, production floor quality checks, and field service applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications and Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePCB assembly quality verification where technicians measure capacitor and inductor values immediately after soldering to detect component misplacement, solder bridges, and counterfeit parts before functional testing\u003c\/li\u003e\n\u003cli\u003ePower supply design validation where engineers characterize output filter inductors and capacitors at multiple frequencies to confirm ripple attenuation and transient response specifications\u003c\/li\u003e\n\u003cli\u003eField equipment repair and maintenance where service technicians rapidly identify failed capacitors, inductors, and resistors in audio amplifiers, switching power supplies, and RF circuits without removing components\u003c\/li\u003e\n\u003cli\u003eComponent procurement quality assurance where incoming inspection personnel verify capacitance values, ESR characteristics, and inductance specifications of bulk component shipments to prevent defective parts entering production\u003c\/li\u003e\n\u003cli\u003eEducational laboratory instruction where students measure impedance parameters of passive components, validate theoretical calculations, and understand frequency-dependent behavior of real-world L, C, and R elements\u003c\/li\u003e\n\u003cli\u003eAntenna and transmission line impedance matching where RF technicians measure characteristic impedance and quality factors of matching networks and tuning components across operating frequency bands\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003cp\u003eBegin by inserting two AA batteries into the rear compartment and powering on the meter. Select your desired test frequency using the frequency selector button, typically 1 kHz for general-purpose component testing or 10 kHz for higher-frequency applications. Choose your measurement mode (L, C, or R) using the mode button, and select the test signal level (0.3V for sensitive components or 1V for standard measurements). For maximum accuracy, perform test lead compensation by shorting the test probes together, pressing the compensation button, and waiting for the display to stabilize at zero before measuring components.\u003c\/p\u003e\n\n\u003cp\u003eConnect the component under test across the test leads, ensuring firm contact to minimize contact resistance. The meter will automatically select the appropriate measurement range and display the primary parameter value. Press the secondary parameter button to view Q factor, dissipation factor, impedance, or ESR alongside the primary measurement. For components with leads, insert them directly into the test probe holes. For surface-mount components or PCB-mounted elements, use the probe tips to contact component pads. Allow 2-3 seconds for the display to stabilize before recording the measurement. For critical measurements, repeat the test at least twice to verify consistency and detect intermittent connection issues.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is the difference between measuring at 1 kHz versus 10 kHz frequencies?\u003c\/summary\u003e\n\u003cp\u003eThe test frequency significantly affects impedance measurements for frequency-dependent components. At 1 kHz, you measure impedance in the audio frequency range suitable for general-purpose components, power supply filters, and audio circuits. At 10 kHz, measurements represent higher-frequency behavior important for RF circuits, switching power supplies, and high-frequency filter designs. Capacitive reactance increases and inductive reactance decreases with frequency, so the same component exhibits different impedance values at different test frequencies. Select the frequency matching your application to obtain meaningful impedance characterization.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhy should I perform test lead compensation before measuring components?\u003c\/summary\u003e\n\u003cp\u003eTest leads possess inherent resistance (typically 0.1-0.5 ohms) and capacitance (5-15 pF), which introduce systematic measurement errors especially for low-value inductors and capacitors. Lead compensation electronically subtracts these parasitic effects from subsequent measurements. Without compensation, a 1 uH inductor might read as 1.2 uH due to lead resistance, and a 10 pF capacitor might read as 15 pF due to lead capacitance. Compensation is particularly critical when measuring components below 100 pF or below 1 uH, or when using extended probe cables. Perform compensation whenever you change test leads or frequency settings.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan the LCR 916 measure ESR (Equivalent Series Resistance) of capacitors?\u003c\/summary\u003e\n\u003cp\u003eYes, the LCR 916 displays ESR as a secondary parameter when in capacitance measurement mode. ESR represents the resistive losses within the capacitor and is critical for power supply design, as high ESR increases voltage ripple and heat dissipation. The meter calculates ESR from the impedance and phase angle of the measured capacitor. ESR values typically range from milliohms for quality film capacitors to several ohms for aged electrolytic capacitors. Monitoring ESR trends helps identify capacitor degradation in field equipment, as ESR increases significantly as electrolytic capacitors age.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhen will I receive my order?\u003c\/summary\u003e\n\u003cp\u003eOrders are dispatched within 1-5 business days from our Bengaluru warehouse. Delivery takes 7-8 days to most locations across India.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is your return and warranty policy?\u003c\/summary\u003e\n\u003cp\u003eWe offer a 7-day return policy on manufacturing defects only. Contact support within 7 days of receipt for free replacement or full refund. Not applicable for user damage or misuse.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eAre bulk discounts available?\u003c\/summary\u003e\n\u003cp\u003eYes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.\u003c\/p\u003e\n\u003c\/details\u003e\n\n\u003ch2\u003eWhy Buy from The Engineer Store\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine Products: Sourced directly from authorized distributors with authentication\u003c\/li\u003e\n\u003cli\u003eExpert Team: Our technical team validates every product before listing\u003c\/li\u003e\n\u003cli\u003eFast Shipping: Dispatched within 1-5 days from our Bengaluru warehouse\u003c\/li\u003e\n\u003cli\u003ePan-India Delivery: 7-8 days to Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata\u003c\/li\u003e\n\u003cli\u003ePayment Options: COD, UPI, credit\/debit cards, net banking, EMI available\u003c\/li\u003e\n\u003cli\u003eTechnical Support: 24\/7 expert guidance via email and WhatsApp\u003c\/li\u003e\n\u003cli\u003eReturns: 7-day return policy on manufacturing defects only\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eBuy GW Instek LCR 916 Handheld LCR Meter Online in India\u003c\/h2\u003e\n\u003cp\u003ePurchase the \u003cstrong\u003eGW Instek LCR 916 Handheld LCR Meter\u003c\/strong\u003e online at \u003ca href=\"https:\/\/theengineerstore.in\"\u003eThe Engineer Store\u003c\/a\u003e, India's trusted source for genuine electronics. We deliver across Bengaluru, Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata, Ahmedabad, Jaipur, and Surat. Get the best price on \u003cstrong\u003eGW Instek LCR 916 Handheld LCR Meter\u003c\/strong\u003e with fast shipping and expert support.\u003c\/p\u003e\n\u003cp\u003eOur team in Bengaluru is available 24\/7 to support your journey from product selection to project completion.\u003c\/p\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":43874147172515,"sku":"TES-EV100443322","price":42493.39,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0628\/4479\/7091\/products\/LCR-916-314x252.jpg?v=1704717349","url":"https:\/\/www.theengineerstore.in\/ta\/products\/gw-instek-lcr-916-handheld-lcr-meter","provider":"The Engineer Store","version":"1.0","type":"link"}