Water Cooling Head Water Cooling Plate 40*320mm
- அலகு விலை
- / ஒன்றுக்கு
Water Cooling Head Water Cooling Plate 40*320mm
The Water Cooling Head Water Cooling Plate 40*320mm is a precision liquid cooling component designed for high-performance thermal management in industrial electronics, laser systems, and semiconductor cooling applications. Professional engineers and technicians use this cooling plate to dissipate concentrated heat loads in compact spaces where traditional air cooling proves inadequate. This product solves critical thermal management challenges by providing efficient heat transfer through direct liquid contact, maintaining optimal operating temperatures for sensitive electronic components and extending equipment lifespan.
Product Overview
The Water Cooling Plate operates on the principle of forced convection heat transfer, where coolant circulates through internal microchannels machined into the aluminum or copper base material. The 40*320mm dimensions provide an optimal surface area for moderate to high heat flux applications, typically handling 500-2000W of thermal energy depending on coolant flow rate and temperature differential. The flat mounting surface ensures excellent thermal contact with heat sources, while the internal channel design minimizes pressure drop and turbulence, enabling efficient heat removal even at lower flow rates between 2-6 liters per minute.
This cooling plate model stands out due to its compact rectangular geometry that fits seamlessly into space-constrained systems such as laser diode arrays, RF amplifiers, and industrial control cabinets. The precision-engineered inlet and outlet ports accommodate standard barbed or threaded fittings, allowing easy integration with existing chiller systems. Advanced manufacturing techniques ensure uniform channel depth and minimal manufacturing tolerances, preventing hot spots and ensuring consistent thermal performance across the entire cooling surface.
Key Specifications
| Specification | Details |
| Product Type | Liquid Water Cooling Plate |
| Dimensions | 40mm x 320mm |
| Material | Aluminum or Copper Alloy |
| Origin | Original/Authentic |
| Warranty | 7 days on manufacturing defects |
| Shipping | 1-5 days from Bengaluru |
| Delivery | 7-8 days across India |
| Support | 24/7 via Email and WhatsApp |
| Port Type | M10 or Barbed Inlet/Outlet |
| Operating Pressure | 0.5-3 bar |
| Recommended Flow Rate | 2-6 liters per minute |
| Thermal Capacity | 500-2000W depending on coolant and flow |
Key Features
- Optimized 40*320mm form factor provides maximum heat dissipation in linear, space-constrained applications with minimal footprint impact
- Precision-machined internal microchannels ensure uniform coolant distribution and turbulent flow for enhanced heat transfer coefficients exceeding 10,000 W/m²K
- Flat mounting surface with high flatness tolerance maintains consistent thermal contact resistance below 0.01 K/W when properly mounted
- Low internal volume design reduces coolant requirement and system startup time, ideal for portable or mobile cooling applications
- Corrosion-resistant aluminum or copper construction withstands extended operation with distilled water or specialized coolant solutions
Applications and Use Cases
- Laser Diode Array Cooling: Maintains precise junction temperatures for high-power laser modules in industrial cutting and marking systems, preventing wavelength drift and power degradation
- RF Amplifier Thermal Management: Dissipates heat from power transistors in telecommunications and radar equipment, ensuring stable gain and linearity across operating frequency ranges
- Semiconductor Test Equipment: Cools DUT (Device Under Test) holders and thermal chambers in semiconductor characterization systems requiring precise temperature control within ±0.5°C
- Industrial Control Cabinet Cooling: Manages heat from power supplies, inverters, and control modules in manufacturing equipment, extending component lifespan and reducing downtime
- Medical Device Thermal Regulation: Maintains optimal operating temperatures in ultrasound transducer arrays and surgical laser systems requiring stable thermal conditions
How to Use
Installation begins with mounting the cooling plate directly onto the heat source using thermal interface material such as thermal grease or phase-change pads to fill microscopic surface irregularities and minimize thermal contact resistance. Secure the plate using mounting brackets or clamps that apply uniform pressure across the entire surface, typically 0.5-1.5 MPa clamping force. Connect the inlet port to your chiller system's outlet using appropriate tubing (typically 10-12mm inner diameter), and connect the outlet port back to the chiller inlet, ensuring the system is filled with degassed coolant before operation to prevent air pockets that reduce thermal performance.
Establish coolant flow at 2-4 liters per minute for most applications, monitoring inlet and outlet temperatures to calculate actual heat dissipation using the formula Q = m × Cp × ΔT, where m is mass flow rate and ΔT is temperature differential. Maintain inlet coolant temperature between 15-35°C for optimal performance, and inspect connection points weekly for leaks during the first month of operation. Replace thermal interface material annually or whenever the cooling plate is removed, as material degradation significantly increases thermal resistance over time.
Frequently Asked Questions
What coolant should I use in the water cooling plate?
Distilled water is the most common and cost-effective option for standard applications. For extended system life and corrosion prevention, use a 50/50 mixture of distilled water and propylene glycol, or specialized cooling fluids designed for electronics cooling. Avoid tap water as mineral content causes scaling and reduces heat transfer efficiency. If using additives, ensure they are compatible with aluminum or copper materials to prevent galvanic corrosion.
What is the maximum operating temperature for this cooling plate?
The aluminum or copper base material can withstand continuous operation up to 80°C, though thermal performance degrades at higher temperatures. We recommend maintaining inlet coolant temperatures below 35°C to ensure the cooling plate surface remains below 60°C under typical load conditions. For applications requiring higher temperature operation, consult our technical team for material upgrade options such as stainless steel variants.
How do I calculate the required chiller capacity for this cooling plate?
Multiply your heat load in watts by 1.2 to account for system losses, then divide by the desired temperature rise across the cooling plate. For example, a 1000W heat load with 5°C temperature rise requires a chiller capacity of 1200W ÷ 5°C = 240W per °C of cooling. This cooling plate typically operates efficiently with chillers rated 500-3000W depending on your specific application requirements.
When will I receive my order?
Orders are dispatched within 1-5 business days from our Bengaluru warehouse. Delivery takes 7-8 days to most locations across India.
What is your return and warranty policy?
We offer a 7-day return policy on manufacturing defects only. Contact support within 7 days of receipt for free replacement or full refund. Not applicable for user damage or misuse.
Are bulk discounts available?
Yes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.
Why Buy from The Engineer Store
- Genuine Products: Sourced directly from authorized distributors with authentication
- Expert Team: Our technical team validates every product before listing
- Fast Shipping: Dispatched within 1-5 days from our Bengaluru warehouse
- Pan-India Delivery: 7-8 days to Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata
- Payment Options: COD, UPI, credit/debit cards, net banking, EMI available
- Technical Support: 24/7 expert guidance via email and WhatsApp
- Returns: 7-day return policy on manufacturing defects only
Buy Water Cooling Head Water Cooling Plate 40*320mm Online in India
Purchase the Water Cooling Head Water Cooling Plate 40*320mm online at The Engineer Store, India's trusted source for genuine electronics. We deliver across Bengaluru, Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata, Ahmedabad, Jaipur, and Surat. Get the best price on Water Cooling Head Water Cooling Plate 40*320mm with fast shipping and expert support.
Our team in Bengaluru is available 24/7 to support your journey from product selection to project completion.
Water Cooling Head Water Cooling Plate 40*320mm
- அலகு விலை
- / ஒன்றுக்கு
உங்கள் வண்டியில் தயாரிப்பு சேர்க்கிறது
நீயும் விரும்புவாய்
Water Cooling Head Water Cooling Plate 40*320mm
The Water Cooling Head Water Cooling Plate 40*320mm is a precision liquid cooling component designed for high-performance thermal management in industrial electronics, laser systems, and semiconductor cooling applications. Professional engineers and technicians use this cooling plate to dissipate concentrated heat loads in compact spaces where traditional air cooling proves inadequate. This product solves critical thermal management challenges by providing efficient heat transfer through direct liquid contact, maintaining optimal operating temperatures for sensitive electronic components and extending equipment lifespan.
Product Overview
The Water Cooling Plate operates on the principle of forced convection heat transfer, where coolant circulates through internal microchannels machined into the aluminum or copper base material. The 40*320mm dimensions provide an optimal surface area for moderate to high heat flux applications, typically handling 500-2000W of thermal energy depending on coolant flow rate and temperature differential. The flat mounting surface ensures excellent thermal contact with heat sources, while the internal channel design minimizes pressure drop and turbulence, enabling efficient heat removal even at lower flow rates between 2-6 liters per minute.
This cooling plate model stands out due to its compact rectangular geometry that fits seamlessly into space-constrained systems such as laser diode arrays, RF amplifiers, and industrial control cabinets. The precision-engineered inlet and outlet ports accommodate standard barbed or threaded fittings, allowing easy integration with existing chiller systems. Advanced manufacturing techniques ensure uniform channel depth and minimal manufacturing tolerances, preventing hot spots and ensuring consistent thermal performance across the entire cooling surface.
Key Specifications
| Specification | Details |
| Product Type | Liquid Water Cooling Plate |
| Dimensions | 40mm x 320mm |
| Material | Aluminum or Copper Alloy |
| Origin | Original/Authentic |
| Warranty | 7 days on manufacturing defects |
| Shipping | 1-5 days from Bengaluru |
| Delivery | 7-8 days across India |
| Support | 24/7 via Email and WhatsApp |
| Port Type | M10 or Barbed Inlet/Outlet |
| Operating Pressure | 0.5-3 bar |
| Recommended Flow Rate | 2-6 liters per minute |
| Thermal Capacity | 500-2000W depending on coolant and flow |
Key Features
- Optimized 40*320mm form factor provides maximum heat dissipation in linear, space-constrained applications with minimal footprint impact
- Precision-machined internal microchannels ensure uniform coolant distribution and turbulent flow for enhanced heat transfer coefficients exceeding 10,000 W/m²K
- Flat mounting surface with high flatness tolerance maintains consistent thermal contact resistance below 0.01 K/W when properly mounted
- Low internal volume design reduces coolant requirement and system startup time, ideal for portable or mobile cooling applications
- Corrosion-resistant aluminum or copper construction withstands extended operation with distilled water or specialized coolant solutions
Applications and Use Cases
- Laser Diode Array Cooling: Maintains precise junction temperatures for high-power laser modules in industrial cutting and marking systems, preventing wavelength drift and power degradation
- RF Amplifier Thermal Management: Dissipates heat from power transistors in telecommunications and radar equipment, ensuring stable gain and linearity across operating frequency ranges
- Semiconductor Test Equipment: Cools DUT (Device Under Test) holders and thermal chambers in semiconductor characterization systems requiring precise temperature control within ±0.5°C
- Industrial Control Cabinet Cooling: Manages heat from power supplies, inverters, and control modules in manufacturing equipment, extending component lifespan and reducing downtime
- Medical Device Thermal Regulation: Maintains optimal operating temperatures in ultrasound transducer arrays and surgical laser systems requiring stable thermal conditions
How to Use
Installation begins with mounting the cooling plate directly onto the heat source using thermal interface material such as thermal grease or phase-change pads to fill microscopic surface irregularities and minimize thermal contact resistance. Secure the plate using mounting brackets or clamps that apply uniform pressure across the entire surface, typically 0.5-1.5 MPa clamping force. Connect the inlet port to your chiller system's outlet using appropriate tubing (typically 10-12mm inner diameter), and connect the outlet port back to the chiller inlet, ensuring the system is filled with degassed coolant before operation to prevent air pockets that reduce thermal performance.
Establish coolant flow at 2-4 liters per minute for most applications, monitoring inlet and outlet temperatures to calculate actual heat dissipation using the formula Q = m × Cp × ΔT, where m is mass flow rate and ΔT is temperature differential. Maintain inlet coolant temperature between 15-35°C for optimal performance, and inspect connection points weekly for leaks during the first month of operation. Replace thermal interface material annually or whenever the cooling plate is removed, as material degradation significantly increases thermal resistance over time.
Frequently Asked Questions
What coolant should I use in the water cooling plate?
Distilled water is the most common and cost-effective option for standard applications. For extended system life and corrosion prevention, use a 50/50 mixture of distilled water and propylene glycol, or specialized cooling fluids designed for electronics cooling. Avoid tap water as mineral content causes scaling and reduces heat transfer efficiency. If using additives, ensure they are compatible with aluminum or copper materials to prevent galvanic corrosion.
What is the maximum operating temperature for this cooling plate?
The aluminum or copper base material can withstand continuous operation up to 80°C, though thermal performance degrades at higher temperatures. We recommend maintaining inlet coolant temperatures below 35°C to ensure the cooling plate surface remains below 60°C under typical load conditions. For applications requiring higher temperature operation, consult our technical team for material upgrade options such as stainless steel variants.
How do I calculate the required chiller capacity for this cooling plate?
Multiply your heat load in watts by 1.2 to account for system losses, then divide by the desired temperature rise across the cooling plate. For example, a 1000W heat load with 5°C temperature rise requires a chiller capacity of 1200W ÷ 5°C = 240W per °C of cooling. This cooling plate typically operates efficiently with chillers rated 500-3000W depending on your specific application requirements.
When will I receive my order?
Orders are dispatched within 1-5 business days from our Bengaluru warehouse. Delivery takes 7-8 days to most locations across India.
What is your return and warranty policy?
We offer a 7-day return policy on manufacturing defects only. Contact support within 7 days of receipt for free replacement or full refund. Not applicable for user damage or misuse.
Are bulk discounts available?
Yes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.
Why Buy from The Engineer Store
- Genuine Products: Sourced directly from authorized distributors with authentication
- Expert Team: Our technical team validates every product before listing
- Fast Shipping: Dispatched within 1-5 days from our Bengaluru warehouse
- Pan-India Delivery: 7-8 days to Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata
- Payment Options: COD, UPI, credit/debit cards, net banking, EMI available
- Technical Support: 24/7 expert guidance via email and WhatsApp
- Returns: 7-day return policy on manufacturing defects only
Buy Water Cooling Head Water Cooling Plate 40*320mm Online in India
Purchase the Water Cooling Head Water Cooling Plate 40*320mm online at The Engineer Store, India's trusted source for genuine electronics. We deliver across Bengaluru, Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata, Ahmedabad, Jaipur, and Surat. Get the best price on Water Cooling Head Water Cooling Plate 40*320mm with fast shipping and expert support.
Our team in Bengaluru is available 24/7 to support your journey from product selection to project completion.
நீயும் விரும்புவாய்
நீயும் விரும்புவாய்
பரிந்துரைக்கப்பட்ட தயாரிப்புகள்
விரைவான சேவை மற்றும் பதில், தயாரிப்பு தரம் மற்றும் பேக்கிங் திருப்திகரமாக உள்ளது.
நன்கு கட்டப்பட்ட கடை, விற்பனை மட்டுமல்ல, அவை உங்கள் கட்டிடத்தையும் உருவாக்குகின்றன. கூட அவர்கள் கருத்தரங்கு நடத்துகிறார் கள். நியாயமான விலையில் பொருட்கள் கிடைக்கும்
சேவை மற்றும் விருந்தோம்பலில் மிகவும் மகிழ்ச்சி. பொறியாளர்களுக்கான திட்டங்களைத் தீர்க்க சரியான இடம். எனது திட்டத்தில் சில சிக்கல்கள் இருந்தன, அங்குள்ள தோழர்களுடன் சென்று அமர்ந்தேன். நாங்கள் 4 மணிநேரம் வேலை செய்தோம், வெளியீடு வந்தது. சிறந்த பகுதியாக நாங்கள் பெற்ற சேவை, மிகவும் மகிழ்ச்சி மற்றும் பாராட்டப்பட்டது. மிக்க நன்றி இன்ஜினியர் ஸ்டோர்
மிகவும் நல்ல வாடிக்கையாளர் சேவை, எப்போதும் உதவ தயாராக உள்ளது. அவர்கள் தொடர்ந்து 4 மணிநேரம் எங்கள் திட்டத்தில் எங்களுக்கு உதவினார்கள், தங்கள் வேலையை விட்டுவிட்டார்கள். கடைசியில் ஒரு பைசா கூட வாங்க மறுத்துவிட்டனர். அற்புதமான மனிதர்கள்
இந்தப் படிவத்தைப் பூர்த்தி செய்வதன் மூலம், எங்களின் மின்னஞ்சல்களைப் பெற நீங்கள் பதிவு செய்கிறீர்கள் மேலும் எந்த நேரத்திலும் குழுவிலகலாம்.
FAQ Below are some of are common questions:
Shipping charge & Delivery timeline.
1) Standard shipping: Rs 49- The order gets delivered within 3-5 working days. (6-7 days in case of the battery as it travels through the surface)
2)Free shipping is applicable to the purchase of Rs.499 and above. The order gets delivered within 5-7 working days. (8-10 days in case of the battery as it travels through the surface)
3)Blue dart Air shipping Rs: 99 and above depending on parcel weight the order gets delivered within3-5working days.
4) Same-day delivery only applicable for Pune-specific pin codes Rs-79 delivery will be done same day between 1 p.m to 9 p.m (the order should be placed before 12:30 p.m)
How do I pay for my order?
You can pay through multiple payment options on theengineerstore.in the checkout page. You can pay through Credit/Debit Card, Internet Banking, Mobile Payments, Manual bank transfer, and Wallets. You can also apply a coupon that you might receive from The Engineer store or redeem The Engineer store points that you have earned from your previous purchases.
Cash on Delivery is offered theengineerstore.in and it is location dependent. Applicability of COD is determined by our system once you enter the pin-code of your area. Also the COD service is chargeable (Rs.25). It is charged by the shipping company for cash handlings.
Once you place a COD order, our executive will call you to confirm your order only after which your order will be processed.
It is best to prepay your order and buy confidently.
You can pay through multiple payment options on theengineerstore.in the checkout page. You can pay through Credit/Debit Card, Internet Banking, Mobile Payments, Manual bank transfer, and Wallets. You can also apply a coupon that you might receive from The Engineer store or redeem The Engineer store points that you have earned from your previous purchases.
Cash on Delivery is offered theengineerstore.in and it is location dependent. Applicability of COD is determined by our system once you enter the pin-code of your area. Also the COD service is chargeable (Rs.25). It is charged by the shipping company for cash handlings.
Once you place a COD order, our executive will call you to confirm your order only after which your order will be processed.
It is best to prepay your order and buy confidently.
It is understandable that a customer will have some technical query before making any purchase on theengineerstore.in.
No worries, we are there to answer your technical queries.
What customer needs to do?Submit a ticket mentioning1. Product code/SKU--->It is found on the product page.(just on the right hand side of the product image)2. Brief description of your query.Once we receive your query, we will get back to you soon with the possible answers.
It happens sometimes, In such cases the money is neither with us nor with the bank but if we receive your money without order, we will refund it within 2-3 working days. Rest assured, the money will come back to your bank account after 10-15 working days once the payment reconciliationhappens at bank's end.
If the money still does not reflect in your bank account, contact us and we will get back to you
What customer needs to do?
Submit a ticket mentioning1. Name of the customer2. Email ID used at the time of placing order.3. Any reference number of transaction that you received from bank.