GW Instek LCR 914 Handheld LCR Meter
- Unit price
- / per
GW Instek LCR 914 Handheld LCR Meter
The GW Instek LCR 914 is a portable handheld LCR meter designed for precise measurement of inductance, capacitance, and resistance across multiple frequency ranges from 100 Hz to 100 kHz. Electronics engineers, field technicians, and quality assurance professionals rely on this instrument to verify component specifications, troubleshoot circuit failures, and validate PCB assembly quality in manufacturing environments. This meter solves the critical challenge of rapid component characterization without requiring bulky benchtop equipment, enabling technicians to perform in-situ testing of passive components in production lines and repair workshops.
Product Overview
The GW Instek LCR 914 operates on the principle of AC bridge measurement, applying a known AC signal across the component under test and analyzing the impedance response to determine L, C, and R values with high accuracy. The meter features a dual-display system that simultaneously shows measurement parameters and derived values, making it invaluable for engineers who need quick verification without manual calculations. Its compact handheld design incorporates a robust measurement engine capable of handling component tolerances from 0.1% to 99.9%, with automatic range selection to minimize user error and improve measurement consistency across different component types.
What distinguishes the LCR 914 from basic multimeters is its ability to measure components at multiple test frequencies, allowing engineers to observe frequency-dependent behavior in capacitors and inductors. The instrument includes built-in test leads with standard 4mm banana connectors and optional kelvin clips for precision measurements, ensuring reliable contact with various component package styles from SMD to through-hole. The LCD display provides clear readability in workshop environments, while the compact form factor allows technicians to carry the meter to production floors, repair benches, and field installations without additional carrying equipment.
Key Specifications
| Specification | Details |
| Product Type | Handheld LCR Meter |
| Brand | GW Instek |
| Model | LCR 914 |
| Origin | Original/Authentic |
| Warranty | 7 days on manufacturing defects |
| Shipping | 1-5 days from Bengaluru |
| Delivery | 7-8 days across India |
| Support | 24/7 via Email and WhatsApp |
| Frequency Range | 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz |
| Inductance Range | 0.01 µH to 9999 H with 0.1% basic accuracy |
| Capacitance Range | 0.001 pF to 9999 µF with 0.1% basic accuracy |
| Resistance Range | 0.01 Ω to 99.99 MΩ with 0.1% basic accuracy |
| Display | Dual LCD display showing primary and secondary parameters |
| Test Signal | 0.3V, 1V AC at 1 kHz standard test frequency |
Key Features
- Multi-frequency measurement capability at 100 Hz, 120 Hz, 1 kHz, 10 kHz, and 100 kHz enables frequency-dependent component characterization for AC circuit design verification
- Dual-display LCD simultaneously shows primary measurement value and secondary derived parameters, reducing calculation time and improving field testing efficiency
- Automatic range selection with manual override option provides flexibility for measuring components with wide tolerance ranges and unusual impedance characteristics
- 0.1% basic accuracy across all measurement ranges ensures reliable component verification for quality control in manufacturing and repair operations
- Compact handheld design with integrated test leads and optional kelvin clip accessories enables portable testing without requiring benchtop space or external measurement setups
- Low test signal voltage of 0.3V to 1V prevents component damage during measurement of sensitive semiconductor junctions and electrolytic capacitors
Applications and Use Cases
- PCB assembly quality verification where incoming component inspection requires rapid measurement of passive components before soldering to detect counterfeits and verify specifications
- Electronics repair and troubleshooting where technicians need to identify failed capacitors and inductors in power supplies, audio amplifiers, and RF circuits without desoldering
- Manufacturing process control in component production facilities where frequency-dependent testing validates capacitor ESR characteristics and inductor Q-factor at operating frequencies
- Educational laboratories and training centers where students learn impedance measurement principles and component characterization through hands-on measurement of real components
- Field service technicians working on industrial equipment who need portable testing capability to diagnose filter component failures and verify replacement parts before installation
- RF and microwave engineering where component measurements at multiple frequencies reveal frequency-dependent behavior critical for impedance matching and filter design validation
How to Use
Begin by selecting the appropriate test frequency from the five available options using the frequency selector button. For general-purpose testing of standard components, 1 kHz is the default selection. Connect the component under test to the meter using the provided test leads, ensuring firm contact with component terminals. Press the measurement button to initiate the test, and the dual display will show the primary measurement value and secondary parameter. For precision measurements of low-impedance components, use the optional kelvin clips to eliminate lead resistance errors by providing separate voltage sensing leads.
When measuring capacitors, select the appropriate frequency range based on your circuit application frequency to observe frequency-dependent behavior. For inductors, use higher test frequencies to measure impedance at actual operating conditions. Always verify that the component is not powered or connected to live circuits before measurement to prevent instrument damage and ensure accurate readings. The automatic range selection will adjust the measurement scale automatically, but you can manually select ranges if you need to measure components at specific impedance levels. After completing measurements, store the meter in a dry environment and ensure test leads are coiled properly to prevent connector damage during transport.
Frequently Asked Questions
What is the difference between measuring at 1 kHz versus 100 kHz on the LCR 914?
Measuring at different frequencies reveals frequency-dependent behavior in components. At 1 kHz, you get the component's impedance at low frequencies, useful for power supply and audio circuits. At 100 kHz, you observe high-frequency behavior critical for RF circuits and high-speed switching applications. Capacitors show lower impedance at higher frequencies, while inductors show higher impedance. This frequency sweep capability allows engineers to verify component suitability for specific circuit applications.
Can the LCR 914 measure components while they are soldered on a PCB?
Yes, the LCR 914 can measure in-circuit components, though accuracy may be affected by parallel impedance paths from other components on the board. For the most accurate measurements, desolder the component or use kelvin clips to isolate the component from surrounding circuitry. In-circuit measurement is useful for quick diagnostics to identify obviously failed components, but out-of-circuit measurement is recommended for precise component verification and quality control testing.
What does the 0.1% basic accuracy specification mean for my measurements?
The 0.1% basic accuracy indicates the meter's uncertainty in ideal conditions without considering environmental factors. For example, when measuring a 1000 µF capacitor, the 0.1% accuracy means the actual value could be within 1 µF of the displayed reading. Actual measurement uncertainty increases with temperature variations, test frequency deviations, and component characteristics. Always allow for additional tolerance when comparing measurements to component datasheets, particularly for components with wide tolerance ratings.
Is the LCR 914 suitable for measuring electrolytic capacitors without risk of damage?
Yes, the LCR 914 is specifically designed for safe measurement of electrolytic capacitors. The low test signal voltage of 0.3V to 1V AC prevents reverse bias stress on electrolytic capacitors, which could cause permanent damage. However, always verify that electrolytic capacitors are fully discharged before measurement by shorting their terminals with an insulated tool. This precaution protects both the capacitor and the meter from potential damage due to residual charge.
When will I receive my order?
Orders are dispatched within 1-5 business days from our Bengaluru warehouse. Delivery takes 7-8 days to most locations across India.
What is your return and warranty policy?
We offer a 7-day return policy on manufacturing defects only. Contact support within 7 days of receipt for free replacement or full refund. Not applicable for user damage or misuse.
Are bulk discounts available?
Yes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.
Why Buy from The Engineer Store
- Genuine Products: Sourced directly from authorized distributors with authentication
- Expert Team: Our technical team validates every product before listing
- Fast Shipping: Dispatched within 1-5 days from our Bengaluru warehouse
- Pan-India Delivery: 7-8 days to Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata
- Payment Options: COD, UPI, credit/debit cards, net banking, EMI available
- Technical Support: 24/7 expert guidance via email and WhatsApp
- Returns: 7-day return policy on manufacturing defects only
Buy GW Instek LCR 914 Handheld LCR Meter Online in India
Purchase the GW Instek LCR 914 Handheld LCR Meter online at The Engineer Store, India's trusted source for genuine electronics. We deliver across Bengaluru, Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata, Ahmedabad, Jaipur, and Surat. Get the best price on GW Instek LCR 914 Handheld LCR Meter with fast shipping and expert support.
Our team in Bengaluru is available 24/7 to support your journey from product selection to project completion.
GW Instek LCR 914 Handheld LCR Meter
- Unit price
- / per
Adding product to your cart
You may also like
GW Instek LCR 914 Handheld LCR Meter
The GW Instek LCR 914 is a portable handheld LCR meter designed for precise measurement of inductance, capacitance, and resistance across multiple frequency ranges from 100 Hz to 100 kHz. Electronics engineers, field technicians, and quality assurance professionals rely on this instrument to verify component specifications, troubleshoot circuit failures, and validate PCB assembly quality in manufacturing environments. This meter solves the critical challenge of rapid component characterization without requiring bulky benchtop equipment, enabling technicians to perform in-situ testing of passive components in production lines and repair workshops.
Product Overview
The GW Instek LCR 914 operates on the principle of AC bridge measurement, applying a known AC signal across the component under test and analyzing the impedance response to determine L, C, and R values with high accuracy. The meter features a dual-display system that simultaneously shows measurement parameters and derived values, making it invaluable for engineers who need quick verification without manual calculations. Its compact handheld design incorporates a robust measurement engine capable of handling component tolerances from 0.1% to 99.9%, with automatic range selection to minimize user error and improve measurement consistency across different component types.
What distinguishes the LCR 914 from basic multimeters is its ability to measure components at multiple test frequencies, allowing engineers to observe frequency-dependent behavior in capacitors and inductors. The instrument includes built-in test leads with standard 4mm banana connectors and optional kelvin clips for precision measurements, ensuring reliable contact with various component package styles from SMD to through-hole. The LCD display provides clear readability in workshop environments, while the compact form factor allows technicians to carry the meter to production floors, repair benches, and field installations without additional carrying equipment.
Key Specifications
| Specification | Details |
| Product Type | Handheld LCR Meter |
| Brand | GW Instek |
| Model | LCR 914 |
| Origin | Original/Authentic |
| Warranty | 7 days on manufacturing defects |
| Shipping | 1-5 days from Bengaluru |
| Delivery | 7-8 days across India |
| Support | 24/7 via Email and WhatsApp |
| Frequency Range | 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz |
| Inductance Range | 0.01 µH to 9999 H with 0.1% basic accuracy |
| Capacitance Range | 0.001 pF to 9999 µF with 0.1% basic accuracy |
| Resistance Range | 0.01 Ω to 99.99 MΩ with 0.1% basic accuracy |
| Display | Dual LCD display showing primary and secondary parameters |
| Test Signal | 0.3V, 1V AC at 1 kHz standard test frequency |
Key Features
- Multi-frequency measurement capability at 100 Hz, 120 Hz, 1 kHz, 10 kHz, and 100 kHz enables frequency-dependent component characterization for AC circuit design verification
- Dual-display LCD simultaneously shows primary measurement value and secondary derived parameters, reducing calculation time and improving field testing efficiency
- Automatic range selection with manual override option provides flexibility for measuring components with wide tolerance ranges and unusual impedance characteristics
- 0.1% basic accuracy across all measurement ranges ensures reliable component verification for quality control in manufacturing and repair operations
- Compact handheld design with integrated test leads and optional kelvin clip accessories enables portable testing without requiring benchtop space or external measurement setups
- Low test signal voltage of 0.3V to 1V prevents component damage during measurement of sensitive semiconductor junctions and electrolytic capacitors
Applications and Use Cases
- PCB assembly quality verification where incoming component inspection requires rapid measurement of passive components before soldering to detect counterfeits and verify specifications
- Electronics repair and troubleshooting where technicians need to identify failed capacitors and inductors in power supplies, audio amplifiers, and RF circuits without desoldering
- Manufacturing process control in component production facilities where frequency-dependent testing validates capacitor ESR characteristics and inductor Q-factor at operating frequencies
- Educational laboratories and training centers where students learn impedance measurement principles and component characterization through hands-on measurement of real components
- Field service technicians working on industrial equipment who need portable testing capability to diagnose filter component failures and verify replacement parts before installation
- RF and microwave engineering where component measurements at multiple frequencies reveal frequency-dependent behavior critical for impedance matching and filter design validation
How to Use
Begin by selecting the appropriate test frequency from the five available options using the frequency selector button. For general-purpose testing of standard components, 1 kHz is the default selection. Connect the component under test to the meter using the provided test leads, ensuring firm contact with component terminals. Press the measurement button to initiate the test, and the dual display will show the primary measurement value and secondary parameter. For precision measurements of low-impedance components, use the optional kelvin clips to eliminate lead resistance errors by providing separate voltage sensing leads.
When measuring capacitors, select the appropriate frequency range based on your circuit application frequency to observe frequency-dependent behavior. For inductors, use higher test frequencies to measure impedance at actual operating conditions. Always verify that the component is not powered or connected to live circuits before measurement to prevent instrument damage and ensure accurate readings. The automatic range selection will adjust the measurement scale automatically, but you can manually select ranges if you need to measure components at specific impedance levels. After completing measurements, store the meter in a dry environment and ensure test leads are coiled properly to prevent connector damage during transport.
Frequently Asked Questions
What is the difference between measuring at 1 kHz versus 100 kHz on the LCR 914?
Measuring at different frequencies reveals frequency-dependent behavior in components. At 1 kHz, you get the component's impedance at low frequencies, useful for power supply and audio circuits. At 100 kHz, you observe high-frequency behavior critical for RF circuits and high-speed switching applications. Capacitors show lower impedance at higher frequencies, while inductors show higher impedance. This frequency sweep capability allows engineers to verify component suitability for specific circuit applications.
Can the LCR 914 measure components while they are soldered on a PCB?
Yes, the LCR 914 can measure in-circuit components, though accuracy may be affected by parallel impedance paths from other components on the board. For the most accurate measurements, desolder the component or use kelvin clips to isolate the component from surrounding circuitry. In-circuit measurement is useful for quick diagnostics to identify obviously failed components, but out-of-circuit measurement is recommended for precise component verification and quality control testing.
What does the 0.1% basic accuracy specification mean for my measurements?
The 0.1% basic accuracy indicates the meter's uncertainty in ideal conditions without considering environmental factors. For example, when measuring a 1000 µF capacitor, the 0.1% accuracy means the actual value could be within 1 µF of the displayed reading. Actual measurement uncertainty increases with temperature variations, test frequency deviations, and component characteristics. Always allow for additional tolerance when comparing measurements to component datasheets, particularly for components with wide tolerance ratings.
Is the LCR 914 suitable for measuring electrolytic capacitors without risk of damage?
Yes, the LCR 914 is specifically designed for safe measurement of electrolytic capacitors. The low test signal voltage of 0.3V to 1V AC prevents reverse bias stress on electrolytic capacitors, which could cause permanent damage. However, always verify that electrolytic capacitors are fully discharged before measurement by shorting their terminals with an insulated tool. This precaution protects both the capacitor and the meter from potential damage due to residual charge.
When will I receive my order?
Orders are dispatched within 1-5 business days from our Bengaluru warehouse. Delivery takes 7-8 days to most locations across India.
What is your return and warranty policy?
We offer a 7-day return policy on manufacturing defects only. Contact support within 7 days of receipt for free replacement or full refund. Not applicable for user damage or misuse.
Are bulk discounts available?
Yes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.
Why Buy from The Engineer Store
- Genuine Products: Sourced directly from authorized distributors with authentication
- Expert Team: Our technical team validates every product before listing
- Fast Shipping: Dispatched within 1-5 days from our Bengaluru warehouse
- Pan-India Delivery: 7-8 days to Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata
- Payment Options: COD, UPI, credit/debit cards, net banking, EMI available
- Technical Support: 24/7 expert guidance via email and WhatsApp
- Returns: 7-day return policy on manufacturing defects only
Buy GW Instek LCR 914 Handheld LCR Meter Online in India
Purchase the GW Instek LCR 914 Handheld LCR Meter online at The Engineer Store, India's trusted source for genuine electronics. We deliver across Bengaluru, Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata, Ahmedabad, Jaipur, and Surat. Get the best price on GW Instek LCR 914 Handheld LCR Meter with fast shipping and expert support.
Our team in Bengaluru is available 24/7 to support your journey from product selection to project completion.
You may also like
You may also like
Recommended products
Quick service and response, product quality and packing is satisfactory.
Well built shop, not only sales but they building your. Even they conduct seminar s. You get materials at reasonable price
Very pleased with the service and hospitality. Perfect place to solve projects for engineers.I had some problems with my project , went and sat down with the guys over there . We worked on it for 4hrs and the output came . Best part was the service we received, very pleased and appreciated. Thank you so much ENGINEER STORE
Very good customer service, always ready to help. They helped us with our project for 4 hrs straight, leaving their work behind. In the end, they refused to take a single penny. Wonderful people
By completing this form, you are signing up to receive our emails and can unsubscribe at any time.
FAQ Below are some of are common questions:
Shipping charge & Delivery timeline.
1) Standard shipping: Rs 49- The order gets delivered within 3-5 working days. (6-7 days in case of the battery as it travels through the surface)
2)Free shipping is applicable to the purchase of Rs.499 and above. The order gets delivered within 5-7 working days. (8-10 days in case of the battery as it travels through the surface)
3)Blue dart Air shipping Rs: 99 and above depending on parcel weight the order gets delivered within3-5working days.
4) Same-day delivery only applicable for Pune-specific pin codes Rs-79 delivery will be done same day between 1 p.m to 9 p.m (the order should be placed before 12:30 p.m)
How do I pay for my order?
You can pay through multiple payment options on theengineerstore.in the checkout page. You can pay through Credit/Debit Card, Internet Banking, Mobile Payments, Manual bank transfer, and Wallets. You can also apply a coupon that you might receive from The Engineer store or redeem The Engineer store points that you have earned from your previous purchases.
Cash on Delivery is offered theengineerstore.in and it is location dependent. Applicability of COD is determined by our system once you enter the pin-code of your area. Also the COD service is chargeable (Rs.25). It is charged by the shipping company for cash handlings.
Once you place a COD order, our executive will call you to confirm your order only after which your order will be processed.
It is best to prepay your order and buy confidently.
You can pay through multiple payment options on theengineerstore.in the checkout page. You can pay through Credit/Debit Card, Internet Banking, Mobile Payments, Manual bank transfer, and Wallets. You can also apply a coupon that you might receive from The Engineer store or redeem The Engineer store points that you have earned from your previous purchases.
Cash on Delivery is offered theengineerstore.in and it is location dependent. Applicability of COD is determined by our system once you enter the pin-code of your area. Also the COD service is chargeable (Rs.25). It is charged by the shipping company for cash handlings.
Once you place a COD order, our executive will call you to confirm your order only after which your order will be processed.
It is best to prepay your order and buy confidently.
It is understandable that a customer will have some technical query before making any purchase on theengineerstore.in.
No worries, we are there to answer your technical queries.
What customer needs to do?Submit a ticket mentioning1. Product code/SKU--->It is found on the product page.(just on the right hand side of the product image)2. Brief description of your query.Once we receive your query, we will get back to you soon with the possible answers.
It happens sometimes, In such cases the money is neither with us nor with the bank but if we receive your money without order, we will refund it within 2-3 working days. Rest assured, the money will come back to your bank account after 10-15 working days once the payment reconciliationhappens at bank's end.
If the money still does not reflect in your bank account, contact us and we will get back to you
What customer needs to do?
Submit a ticket mentioning1. Name of the customer2. Email ID used at the time of placing order.3. Any reference number of transaction that you received from bank.