Kamoer KHS-SW-S40 12V brushed DC motor peristaltic pump

The Kamoer KHS-SW-S40 is a precision 12V brushed DC motor-driven peristaltic pump engineered for accurate, pulse-free fluid transfer in laboratory, medical, and industrial automation applications. This compact pump delivers consistent flow rates between 0.5 to 40 mL/min with minimal pulsation, making it ideal for pharmaceutical dispensing, aquarium dosing, and analytical instrumentation where precision matters. The brushed DC motor provides reliable operation with variable speed control, eliminating the need for external flow regulators in most applications.

Product Overview

The Kamoer KHS-SW-S40 operates on the peristaltic pump principle, where a rotating rotor with rollers sequentially compresses a flexible silicone tube, creating a one-way flow without the fluid contacting internal pump components. This design ensures chemical compatibility with aggressive liquids, eliminates cross-contamination, and requires minimal maintenance. The 12V brushed DC motor provides direct voltage control for speed adjustment, allowing operators to fine-tune flow rates in real-time without additional controllers. The pump head accommodates standard silicone tubing with inner diameter ranging from 1.6mm to 2.4mm, offering flexibility for different viscosity fluids from water-thin solutions to moderate-viscosity reagents.

The S40 model designation indicates a maximum flow capacity of 40 mL/min at full motor speed, with proportional flow reduction at lower voltages. The brushed motor design delivers consistent torque across the operating range, ensuring reliable performance in temperature-controlled laboratory environments and field installations. Built with corrosion-resistant materials and sealed bearing assemblies, this pump withstands continuous operation in humid conditions and chemical-rich environments. The compact form factor makes it suitable for integration into automated liquid handling systems, environmental monitoring equipment, and medical infusion devices where space constraints exist.

Key Specifications

Specification Details
Product Type 12V Brushed DC Motor Peristaltic Pump
Brand Kamoer
Model KHS-SW-S40
Origin Original/Authentic
Warranty 7 days on manufacturing defects
Shipping 1-5 days from Bengaluru
Delivery 7-8 days across India
Support 24/7 via Email and WhatsApp
Operating Voltage 12V DC
Motor Type Brushed DC Motor
Maximum Flow Rate 40 mL/min at full speed
Flow Range 0.5 to 40 mL/min variable
Tubing Compatibility Silicone tube ID 1.6mm to 2.4mm
Pressure Rating 0.5 bar maximum
Pulsation Less than 3 percent
Operating Temperature 5 to 40 degrees Celsius

Key Features

  • Brushed DC motor with variable speed control for proportional flow adjustment from 0.5 to 40 mL/min without external regulators
  • Peristaltic pump design eliminates fluid contact with internal components, ensuring chemical compatibility with aggressive reagents and pharmaceutical compounds
  • Low pulsation output below 3 percent, critical for precision analytical applications requiring stable baseline measurements
  • Compact modular design with quick-change tubing cartridge system for rapid maintenance and tubing replacement
  • 12V DC direct operation with simple two-wire connection, compatible with battery power, laboratory power supplies, and automotive electrical systems
  • Sealed bearing assemblies and corrosion-resistant materials for reliable performance in humid laboratory and industrial environments

Applications and Use Cases

  • Pharmaceutical and chemical laboratories for precise reagent dispensing in automated analytical instruments and liquid chromatography sample preparation systems
  • Medical and laboratory equipment such as automated blood analyzers, immunoassay systems, and diagnostic analyzers requiring accurate microliter-level fluid transfer
  • Aquarium and hydroponics systems for nutrient dosing and water treatment chemical injection with programmable timing and adjustable flow rates
  • Environmental monitoring equipment for water quality testing, where peristaltic pumps prevent contamination of sensitive samples and reagents
  • Industrial automation and process control for chemical injection in manufacturing, wastewater treatment, and food processing applications
  • Research laboratories for cell culture media perfusion, bioreactor nutrient feeding, and continuous sampling applications requiring pulse-free flow

How to Use

Installation begins with selecting appropriate silicone tubing with inner diameter between 1.6mm and 2.4mm, inserting it into the pump head cartridge until fully seated. Connect the two motor leads to your 12V DC power source, ensuring correct polarity for forward flow direction. For variable speed operation, connect the positive lead through a PWM controller or variable voltage supply rather than directly to the power source. Prime the tubing by running the pump for 10-15 seconds at low speed to remove air pockets before connecting to your application system. Verify smooth rotation without grinding sounds, which would indicate improper tubing seating or internal debris.

During operation, monitor the tubing for signs of wear or degradation, as silicone tubes degrade with exposure to certain chemicals and UV light. Replace tubing every 3-6 months depending on chemical exposure and continuous operation hours. For applications requiring precise flow rates, calibrate the pump by measuring actual output volume at your intended operating voltage over a fixed time period, then adjust voltage accordingly. Maintain the pump in a temperature-controlled environment between 5 and 40 degrees Celsius to ensure consistent motor performance and prevent thermal drift in flow rate accuracy. Clean the pump head exterior with a damp cloth after use, and store with the tubing removed to prevent permanent compression set in the silicone.

Frequently Asked Questions

What is the difference between peristaltic and centrifugal pump designs for laboratory applications?

Peristaltic pumps like the KHS-SW-S40 compress tubing sequentially to move fluid without internal contact, making them ideal for aggressive chemicals, sterile applications, and low-pulsation requirements. Centrifugal pumps use rotating impellers and require internal seals, limiting chemical compatibility and producing higher pulsation unsuitable for precision analytical work. Peristaltic pumps excel in laboratory settings where sample integrity and chemical compatibility are critical, while centrifugal pumps are better for high-volume, low-precision applications.

Can I use the KHS-SW-S40 with thick or viscous fluids?

The KHS-SW-S40 is rated for fluids up to moderate viscosity with a maximum pressure rating of 0.5 bar. For highly viscous fluids like glycerin or oils, flow rate will decrease significantly and motor torque requirements increase, potentially reducing motor lifespan. Test your specific fluid at low speed first to verify adequate performance. For viscous fluids exceeding 500 cP, consider larger tubing diameters or dedicated high-viscosity pump models with higher pressure ratings.

How do I control the flow rate precisely without a PWM controller?

The KHS-SW-S40 flow rate is directly proportional to motor speed, which is proportional to applied voltage. Using a variable DC power supply, you can adjust voltage from 0 to 12V to achieve proportional flow rate changes. For example, 6V typically delivers approximately 20 mL/min, while 3V delivers approximately 10 mL/min. Calibrate your specific pump at your intended operating voltages by measuring actual output over a fixed time period, then create a voltage-to-flow-rate lookup table for your application.

What tubing materials are compatible with the pump?

The KHS-SW-S40 is designed for silicone tubing with inner diameters from 1.6mm to 2.4mm. Silicone is chemically inert and compatible with most laboratory reagents, pharmaceuticals, and aqueous solutions. For specialized applications with aggressive solvents like toluene or acetone, verify silicone compatibility first. Do not use PVC or latex tubing, as they degrade rapidly with the peristaltic compression action and may leach plasticizers into your fluid.

When will I receive my order?

Orders are dispatched within 1-5 business days from our Bengaluru warehouse. Delivery takes 7-8 days to most locations across India.

What is your return and warranty policy?

We offer a 7-day return policy on manufacturing defects only. Contact support within 7 days of receipt for free replacement or full refund. Not applicable for user damage or misuse.

Are bulk discounts available?

Yes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.

Why Buy from The Engineer Store

  • Genuine Products: Sourced directly from authorized distributors with authentication
  • Expert Team: Our technical team validates every product before listing
  • Fast Shipping: Dispatched within 1-5 days from our Bengaluru warehouse
  • Pan-India Delivery: 7-8 days to Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata
  • Payment Options: COD, UPI, credit/debit cards, net banking, EMI available
  • Technical Support: 24/7 expert guidance via email and WhatsApp
  • Returns: 7-day return policy on manufacturing defects only

Buy Kamoer KHS-SW-S40 12V brushed DC motor peristaltic pump Online in India

Purchase the Kamoer KHS-SW-S40 12V brushed DC motor peristaltic pump online at The Engineer Store, India's trusted source for genuine electronics. We deliver across Bengaluru, Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata, Ahmedabad, Jaipur, and Surat. Get the best price on Kamoer KHS-SW-S40 12V brushed DC motor peristaltic pump with fast shipping and expert support.

Our team in Bengaluru is available 24/7 to support your journey from product selection to project completion.

Sale

Kamoer KHS-SW-S40 12V brushed DC motor peristaltic pump

SKU: TES-EVN957
Regular price Rs. 3,448.98 Rs. 2,162.93 37% off
Unit price
per
No Reviews
3-5 Working Days Dispatch
Availability
 
(0 in cart)
Shipping calculated at checkout.

You may also like

Kamoer KHS-SW-S40 12V brushed DC motor peristaltic pump

The Kamoer KHS-SW-S40 is a precision 12V brushed DC motor-driven peristaltic pump engineered for accurate, pulse-free fluid transfer in laboratory, medical, and industrial automation applications. This compact pump delivers consistent flow rates between 0.5 to 40 mL/min with minimal pulsation, making it ideal for pharmaceutical dispensing, aquarium dosing, and analytical instrumentation where precision matters. The brushed DC motor provides reliable operation with variable speed control, eliminating the need for external flow regulators in most applications.

Product Overview

The Kamoer KHS-SW-S40 operates on the peristaltic pump principle, where a rotating rotor with rollers sequentially compresses a flexible silicone tube, creating a one-way flow without the fluid contacting internal pump components. This design ensures chemical compatibility with aggressive liquids, eliminates cross-contamination, and requires minimal maintenance. The 12V brushed DC motor provides direct voltage control for speed adjustment, allowing operators to fine-tune flow rates in real-time without additional controllers. The pump head accommodates standard silicone tubing with inner diameter ranging from 1.6mm to 2.4mm, offering flexibility for different viscosity fluids from water-thin solutions to moderate-viscosity reagents.

The S40 model designation indicates a maximum flow capacity of 40 mL/min at full motor speed, with proportional flow reduction at lower voltages. The brushed motor design delivers consistent torque across the operating range, ensuring reliable performance in temperature-controlled laboratory environments and field installations. Built with corrosion-resistant materials and sealed bearing assemblies, this pump withstands continuous operation in humid conditions and chemical-rich environments. The compact form factor makes it suitable for integration into automated liquid handling systems, environmental monitoring equipment, and medical infusion devices where space constraints exist.

Key Specifications

Specification Details
Product Type 12V Brushed DC Motor Peristaltic Pump
Brand Kamoer
Model KHS-SW-S40
Origin Original/Authentic
Warranty 7 days on manufacturing defects
Shipping 1-5 days from Bengaluru
Delivery 7-8 days across India
Support 24/7 via Email and WhatsApp
Operating Voltage 12V DC
Motor Type Brushed DC Motor
Maximum Flow Rate 40 mL/min at full speed
Flow Range 0.5 to 40 mL/min variable
Tubing Compatibility Silicone tube ID 1.6mm to 2.4mm
Pressure Rating 0.5 bar maximum
Pulsation Less than 3 percent
Operating Temperature 5 to 40 degrees Celsius

Key Features

  • Brushed DC motor with variable speed control for proportional flow adjustment from 0.5 to 40 mL/min without external regulators
  • Peristaltic pump design eliminates fluid contact with internal components, ensuring chemical compatibility with aggressive reagents and pharmaceutical compounds
  • Low pulsation output below 3 percent, critical for precision analytical applications requiring stable baseline measurements
  • Compact modular design with quick-change tubing cartridge system for rapid maintenance and tubing replacement
  • 12V DC direct operation with simple two-wire connection, compatible with battery power, laboratory power supplies, and automotive electrical systems
  • Sealed bearing assemblies and corrosion-resistant materials for reliable performance in humid laboratory and industrial environments

Applications and Use Cases

  • Pharmaceutical and chemical laboratories for precise reagent dispensing in automated analytical instruments and liquid chromatography sample preparation systems
  • Medical and laboratory equipment such as automated blood analyzers, immunoassay systems, and diagnostic analyzers requiring accurate microliter-level fluid transfer
  • Aquarium and hydroponics systems for nutrient dosing and water treatment chemical injection with programmable timing and adjustable flow rates
  • Environmental monitoring equipment for water quality testing, where peristaltic pumps prevent contamination of sensitive samples and reagents
  • Industrial automation and process control for chemical injection in manufacturing, wastewater treatment, and food processing applications
  • Research laboratories for cell culture media perfusion, bioreactor nutrient feeding, and continuous sampling applications requiring pulse-free flow

How to Use

Installation begins with selecting appropriate silicone tubing with inner diameter between 1.6mm and 2.4mm, inserting it into the pump head cartridge until fully seated. Connect the two motor leads to your 12V DC power source, ensuring correct polarity for forward flow direction. For variable speed operation, connect the positive lead through a PWM controller or variable voltage supply rather than directly to the power source. Prime the tubing by running the pump for 10-15 seconds at low speed to remove air pockets before connecting to your application system. Verify smooth rotation without grinding sounds, which would indicate improper tubing seating or internal debris.

During operation, monitor the tubing for signs of wear or degradation, as silicone tubes degrade with exposure to certain chemicals and UV light. Replace tubing every 3-6 months depending on chemical exposure and continuous operation hours. For applications requiring precise flow rates, calibrate the pump by measuring actual output volume at your intended operating voltage over a fixed time period, then adjust voltage accordingly. Maintain the pump in a temperature-controlled environment between 5 and 40 degrees Celsius to ensure consistent motor performance and prevent thermal drift in flow rate accuracy. Clean the pump head exterior with a damp cloth after use, and store with the tubing removed to prevent permanent compression set in the silicone.

Frequently Asked Questions

What is the difference between peristaltic and centrifugal pump designs for laboratory applications?

Peristaltic pumps like the KHS-SW-S40 compress tubing sequentially to move fluid without internal contact, making them ideal for aggressive chemicals, sterile applications, and low-pulsation requirements. Centrifugal pumps use rotating impellers and require internal seals, limiting chemical compatibility and producing higher pulsation unsuitable for precision analytical work. Peristaltic pumps excel in laboratory settings where sample integrity and chemical compatibility are critical, while centrifugal pumps are better for high-volume, low-precision applications.

Can I use the KHS-SW-S40 with thick or viscous fluids?

The KHS-SW-S40 is rated for fluids up to moderate viscosity with a maximum pressure rating of 0.5 bar. For highly viscous fluids like glycerin or oils, flow rate will decrease significantly and motor torque requirements increase, potentially reducing motor lifespan. Test your specific fluid at low speed first to verify adequate performance. For viscous fluids exceeding 500 cP, consider larger tubing diameters or dedicated high-viscosity pump models with higher pressure ratings.

How do I control the flow rate precisely without a PWM controller?

The KHS-SW-S40 flow rate is directly proportional to motor speed, which is proportional to applied voltage. Using a variable DC power supply, you can adjust voltage from 0 to 12V to achieve proportional flow rate changes. For example, 6V typically delivers approximately 20 mL/min, while 3V delivers approximately 10 mL/min. Calibrate your specific pump at your intended operating voltages by measuring actual output over a fixed time period, then create a voltage-to-flow-rate lookup table for your application.

What tubing materials are compatible with the pump?

The KHS-SW-S40 is designed for silicone tubing with inner diameters from 1.6mm to 2.4mm. Silicone is chemically inert and compatible with most laboratory reagents, pharmaceuticals, and aqueous solutions. For specialized applications with aggressive solvents like toluene or acetone, verify silicone compatibility first. Do not use PVC or latex tubing, as they degrade rapidly with the peristaltic compression action and may leach plasticizers into your fluid.

When will I receive my order?

Orders are dispatched within 1-5 business days from our Bengaluru warehouse. Delivery takes 7-8 days to most locations across India.

What is your return and warranty policy?

We offer a 7-day return policy on manufacturing defects only. Contact support within 7 days of receipt for free replacement or full refund. Not applicable for user damage or misuse.

Are bulk discounts available?

Yes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.

Why Buy from The Engineer Store

  • Genuine Products: Sourced directly from authorized distributors with authentication
  • Expert Team: Our technical team validates every product before listing
  • Fast Shipping: Dispatched within 1-5 days from our Bengaluru warehouse
  • Pan-India Delivery: 7-8 days to Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata
  • Payment Options: COD, UPI, credit/debit cards, net banking, EMI available
  • Technical Support: 24/7 expert guidance via email and WhatsApp
  • Returns: 7-day return policy on manufacturing defects only

Buy Kamoer KHS-SW-S40 12V brushed DC motor peristaltic pump Online in India

Purchase the Kamoer KHS-SW-S40 12V brushed DC motor peristaltic pump online at The Engineer Store, India's trusted source for genuine electronics. We deliver across Bengaluru, Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata, Ahmedabad, Jaipur, and Surat. Get the best price on Kamoer KHS-SW-S40 12V brushed DC motor peristaltic pump with fast shipping and expert support.

Our team in Bengaluru is available 24/7 to support your journey from product selection to project completion.