GW Instek GFC 8131 H Frequency Counter
- यूनिट मूल्य
- / प्रति
GW Instek GFC 8131 H Frequency Counter
The GW Instek GFC 8131 H is a precision frequency counter designed for accurate measurement of signal frequencies up to 3 GHz with exceptional resolution and stability. Electronics engineers, RF technicians, and telecommunications professionals rely on this instrument for precise frequency verification, oscillator calibration, and signal integrity testing in laboratory and field environments. This counter solves the critical challenge of measuring frequency with high accuracy across a wide range of applications, from component testing to complex system diagnostics.
Product Overview
The GFC 8131 H operates on the principle of direct frequency counting, utilizing advanced digital signal processing to capture and analyze incoming signals with minimal measurement uncertainty. The instrument features a high-resolution display and intelligent input conditioning circuits that automatically optimize sensitivity across different frequency bands. Its architecture includes multiple input channels with selectable impedance matching, allowing seamless measurement of both high-impedance and low-impedance sources without signal degradation. The counter employs a temperature-compensated crystal oscillator (TCXO) as its timebase reference, ensuring long-term frequency stability and measurement repeatability across varying environmental conditions.
What distinguishes the GFC 8131 H from conventional counters is its extended frequency range capability, advanced triggering mechanisms, and comprehensive measurement functions including period, ratio, and time interval analysis. The instrument incorporates intelligent autoranging that automatically selects optimal measurement gates and sensitivity levels, reducing operator error and improving measurement confidence. Its robust construction and industrial-grade components make it suitable for both benchtop laboratory use and portable field applications, while the intuitive interface enables rapid setup and measurement execution without extensive training.
Key Specifications
| Specification | Details |
| Product Type | Digital Frequency Counter |
| Brand | GW Instek |
| Origin | Original/Authentic |
| Warranty | 7 days on manufacturing defects |
| Shipping | 1-5 days from Bengaluru |
| Delivery | 7-8 days across India |
| Support | 24/7 via Email and WhatsApp |
| Frequency Range | 10 Hz to 3 GHz |
| Resolution | 1 Hz at 1 second gate time |
| Measurement Accuracy | ±(1 count + timebase accuracy) |
| Timebase Stability | ±5 ppm over 0 to 50°C |
| Input Impedance | 50 Ohm and 1 MΩ selectable |
| Display | 8-digit LED display with auto-ranging |
Key Features
- Extended frequency measurement range from 10 Hz to 3 GHz enabling comprehensive RF and microwave signal characterization
- High-resolution 1 Hz measurement capability at 1-second gate time providing precise frequency determination for crystal oscillators and frequency standards
- Dual input impedance selection (50 Ohm and 1 MΩ) allowing direct connection to RF systems and general-purpose signal sources without external adapters
- Intelligent autoranging and automatic sensitivity adjustment reducing manual configuration and improving measurement repeatability across diverse signal types
- Multiple measurement modes including frequency, period, ratio, and time interval for comprehensive signal analysis and system troubleshooting
- Temperature-compensated crystal oscillator timebase ensuring measurement stability and accuracy across extended operating temperature ranges
Applications and Use Cases
- RF oscillator and crystal verification in telecommunications equipment manufacturing where frequency tolerance specifications must be validated within ±5 ppm requirements
- Microwave system alignment and frequency calibration in radar and satellite communication facilities requiring precise frequency reference standards
- Clock signal integrity testing in digital systems and embedded applications to verify timing accuracy and detect frequency drift in real-time applications
- Component characterization and quality assurance in electronics manufacturing where frequency response of filters, oscillators, and synthesizers must be documented
- Field service and maintenance of communication infrastructure including base stations, repeaters, and transmission equipment requiring portable frequency verification
How to Use
Begin by selecting the appropriate input connector and impedance setting based on your signal source characteristics. For 50 Ohm RF signals, connect directly to the RF input; for general-purpose signals up to 1 MHz, use the 1 MΩ input with appropriate attenuation if signal levels exceed 300V peak. Power on the instrument and allow a 5-minute warm-up period for the TCXO timebase to stabilize, ensuring optimal measurement accuracy. Select your desired measurement function using the front panel controls and set the gate time appropriate to your required resolution—longer gate times provide higher resolution but require more stable signals.
Connect your signal source to the selected input and observe the display for frequency reading. The autoranging feature will automatically optimize sensitivity, but you may manually adjust trigger level if the signal has unusual characteristics or low amplitude. For best results with weak signals below 100 mV, enable the high-sensitivity mode and ensure proper shielding of input cables to minimize noise coupling. Record multiple measurements over time to assess frequency stability and drift characteristics. After completing measurements, properly terminate unused inputs with 50 Ohm termination caps to prevent spurious coupling and maintain measurement integrity.
Frequently Asked Questions
What is the minimum signal amplitude required for accurate frequency measurement?
The GFC 8131 H can measure signals as low as 50 mV RMS in high-sensitivity mode, though 100 mV RMS or higher is recommended for optimal accuracy and noise immunity. For very weak signals, ensure proper shielding and grounding to prevent environmental noise interference. The instrument's automatic sensitivity adjustment helps optimize measurement conditions across different signal amplitudes.
How do I measure frequency of signals above 3 GHz?
For frequencies beyond 3 GHz, you can use external prescalers or divide-down techniques. Connect the high-frequency signal through a prescaler that reduces the frequency by a known factor (typically 10:1 or 100:1), then measure the output frequency and multiply by the prescaler ratio. GW Instek offers compatible prescaler modules for extended frequency range applications.
What is the difference between gate time settings and how do they affect measurements?
Gate time determines the measurement window duration. Longer gate times (10 seconds) provide higher resolution and better frequency stability measurements but require more stable input signals. Shorter gate times (0.1 seconds) are useful for rapidly changing signals but have lower resolution. For crystal oscillator testing, use 10-second gate time; for dynamic signal analysis, use 1-second gate time as a compromise.
Can I measure period and time interval with this counter?
Yes, the GFC 8131 H includes period measurement mode for determining signal period with high precision, and time interval measurement for analyzing timing relationships between multiple signals. These functions are essential for jitter analysis, timing synchronization verification, and clock signal characterization in digital systems.
When will I receive my order?
Orders are dispatched within 1-5 business days from our Bengaluru warehouse. Delivery takes 7-8 days to most locations across India.
What is your return and warranty policy?
We offer a 7-day return policy on manufacturing defects only. Contact support within 7 days of receipt for free replacement or full refund. Not applicable for user damage or misuse.
Are bulk discounts available?
Yes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.
Why Buy from The Engineer Store
- Genuine Products: Sourced directly from authorized distributors with authentication
- Expert Team: Our technical team validates every product before listing
- Fast Shipping: Dispatched within 1-5 days from our Bengaluru warehouse
- Pan-India Delivery: 7-8 days to Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata
- Payment Options: COD, UPI, credit/debit cards, net banking, EMI available
- Technical Support: 24/7 expert guidance via email and WhatsApp
- Returns: 7-day return policy on manufacturing defects only
Buy GW Instek GFC 8131 H Frequency Counter Online in India
Purchase the GW Instek GFC 8131 H Frequency Counter online at The Engineer Store, India's trusted source for genuine electronics. We deliver across Bengaluru, Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata, Ahmedabad, Jaipur, and Surat. Get the best price on GW Instek GFC 8131 H Frequency Counter with fast shipping and expert support.
Our team in Bengaluru is available 24/7 to support your journey from product selection to project completion.
GW Instek GFC 8131 H Frequency Counter
- यूनिट मूल्य
- / प्रति
अपने कार्ट में उत्पाद जोड़ना
आपको यह भी पसंद आ सकता हैं
GW Instek GFC 8131 H Frequency Counter
The GW Instek GFC 8131 H is a precision frequency counter designed for accurate measurement of signal frequencies up to 3 GHz with exceptional resolution and stability. Electronics engineers, RF technicians, and telecommunications professionals rely on this instrument for precise frequency verification, oscillator calibration, and signal integrity testing in laboratory and field environments. This counter solves the critical challenge of measuring frequency with high accuracy across a wide range of applications, from component testing to complex system diagnostics.
Product Overview
The GFC 8131 H operates on the principle of direct frequency counting, utilizing advanced digital signal processing to capture and analyze incoming signals with minimal measurement uncertainty. The instrument features a high-resolution display and intelligent input conditioning circuits that automatically optimize sensitivity across different frequency bands. Its architecture includes multiple input channels with selectable impedance matching, allowing seamless measurement of both high-impedance and low-impedance sources without signal degradation. The counter employs a temperature-compensated crystal oscillator (TCXO) as its timebase reference, ensuring long-term frequency stability and measurement repeatability across varying environmental conditions.
What distinguishes the GFC 8131 H from conventional counters is its extended frequency range capability, advanced triggering mechanisms, and comprehensive measurement functions including period, ratio, and time interval analysis. The instrument incorporates intelligent autoranging that automatically selects optimal measurement gates and sensitivity levels, reducing operator error and improving measurement confidence. Its robust construction and industrial-grade components make it suitable for both benchtop laboratory use and portable field applications, while the intuitive interface enables rapid setup and measurement execution without extensive training.
Key Specifications
| Specification | Details |
| Product Type | Digital Frequency Counter |
| Brand | GW Instek |
| Origin | Original/Authentic |
| Warranty | 7 days on manufacturing defects |
| Shipping | 1-5 days from Bengaluru |
| Delivery | 7-8 days across India |
| Support | 24/7 via Email and WhatsApp |
| Frequency Range | 10 Hz to 3 GHz |
| Resolution | 1 Hz at 1 second gate time |
| Measurement Accuracy | ±(1 count + timebase accuracy) |
| Timebase Stability | ±5 ppm over 0 to 50°C |
| Input Impedance | 50 Ohm and 1 MΩ selectable |
| Display | 8-digit LED display with auto-ranging |
Key Features
- Extended frequency measurement range from 10 Hz to 3 GHz enabling comprehensive RF and microwave signal characterization
- High-resolution 1 Hz measurement capability at 1-second gate time providing precise frequency determination for crystal oscillators and frequency standards
- Dual input impedance selection (50 Ohm and 1 MΩ) allowing direct connection to RF systems and general-purpose signal sources without external adapters
- Intelligent autoranging and automatic sensitivity adjustment reducing manual configuration and improving measurement repeatability across diverse signal types
- Multiple measurement modes including frequency, period, ratio, and time interval for comprehensive signal analysis and system troubleshooting
- Temperature-compensated crystal oscillator timebase ensuring measurement stability and accuracy across extended operating temperature ranges
Applications and Use Cases
- RF oscillator and crystal verification in telecommunications equipment manufacturing where frequency tolerance specifications must be validated within ±5 ppm requirements
- Microwave system alignment and frequency calibration in radar and satellite communication facilities requiring precise frequency reference standards
- Clock signal integrity testing in digital systems and embedded applications to verify timing accuracy and detect frequency drift in real-time applications
- Component characterization and quality assurance in electronics manufacturing where frequency response of filters, oscillators, and synthesizers must be documented
- Field service and maintenance of communication infrastructure including base stations, repeaters, and transmission equipment requiring portable frequency verification
How to Use
Begin by selecting the appropriate input connector and impedance setting based on your signal source characteristics. For 50 Ohm RF signals, connect directly to the RF input; for general-purpose signals up to 1 MHz, use the 1 MΩ input with appropriate attenuation if signal levels exceed 300V peak. Power on the instrument and allow a 5-minute warm-up period for the TCXO timebase to stabilize, ensuring optimal measurement accuracy. Select your desired measurement function using the front panel controls and set the gate time appropriate to your required resolution—longer gate times provide higher resolution but require more stable signals.
Connect your signal source to the selected input and observe the display for frequency reading. The autoranging feature will automatically optimize sensitivity, but you may manually adjust trigger level if the signal has unusual characteristics or low amplitude. For best results with weak signals below 100 mV, enable the high-sensitivity mode and ensure proper shielding of input cables to minimize noise coupling. Record multiple measurements over time to assess frequency stability and drift characteristics. After completing measurements, properly terminate unused inputs with 50 Ohm termination caps to prevent spurious coupling and maintain measurement integrity.
Frequently Asked Questions
What is the minimum signal amplitude required for accurate frequency measurement?
The GFC 8131 H can measure signals as low as 50 mV RMS in high-sensitivity mode, though 100 mV RMS or higher is recommended for optimal accuracy and noise immunity. For very weak signals, ensure proper shielding and grounding to prevent environmental noise interference. The instrument's automatic sensitivity adjustment helps optimize measurement conditions across different signal amplitudes.
How do I measure frequency of signals above 3 GHz?
For frequencies beyond 3 GHz, you can use external prescalers or divide-down techniques. Connect the high-frequency signal through a prescaler that reduces the frequency by a known factor (typically 10:1 or 100:1), then measure the output frequency and multiply by the prescaler ratio. GW Instek offers compatible prescaler modules for extended frequency range applications.
What is the difference between gate time settings and how do they affect measurements?
Gate time determines the measurement window duration. Longer gate times (10 seconds) provide higher resolution and better frequency stability measurements but require more stable input signals. Shorter gate times (0.1 seconds) are useful for rapidly changing signals but have lower resolution. For crystal oscillator testing, use 10-second gate time; for dynamic signal analysis, use 1-second gate time as a compromise.
Can I measure period and time interval with this counter?
Yes, the GFC 8131 H includes period measurement mode for determining signal period with high precision, and time interval measurement for analyzing timing relationships between multiple signals. These functions are essential for jitter analysis, timing synchronization verification, and clock signal characterization in digital systems.
When will I receive my order?
Orders are dispatched within 1-5 business days from our Bengaluru warehouse. Delivery takes 7-8 days to most locations across India.
What is your return and warranty policy?
We offer a 7-day return policy on manufacturing defects only. Contact support within 7 days of receipt for free replacement or full refund. Not applicable for user damage or misuse.
Are bulk discounts available?
Yes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.
Why Buy from The Engineer Store
- Genuine Products: Sourced directly from authorized distributors with authentication
- Expert Team: Our technical team validates every product before listing
- Fast Shipping: Dispatched within 1-5 days from our Bengaluru warehouse
- Pan-India Delivery: 7-8 days to Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata
- Payment Options: COD, UPI, credit/debit cards, net banking, EMI available
- Technical Support: 24/7 expert guidance via email and WhatsApp
- Returns: 7-day return policy on manufacturing defects only
Buy GW Instek GFC 8131 H Frequency Counter Online in India
Purchase the GW Instek GFC 8131 H Frequency Counter online at The Engineer Store, India's trusted source for genuine electronics. We deliver across Bengaluru, Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata, Ahmedabad, Jaipur, and Surat. Get the best price on GW Instek GFC 8131 H Frequency Counter with fast shipping and expert support.
Our team in Bengaluru is available 24/7 to support your journey from product selection to project completion.
आपको यह भी पसंद आ सकता हैं
आपको यह भी पसंद आ सकता हैं
सिफ़ारिश किये हुए उत्पाद
त्वरित सेवा और प्रतिक्रिया, उत्पाद की गुणवत्ता और पैकिंग संतोषजनक है।
अच्छी तरह से निर्मित दुकान, न केवल बिक्री बल्कि वे आपका निर्माण भी कर रहे हैं। यहां तक कि वे सेमिनार भी आयोजित करते हैं. आपको उचित मूल्य पर सामग्री मिलती है
सेवा और आतिथ्य से बहुत प्रसन्न हूं। इंजीनियरों के लिए परियोजनाओं को हल करने के लिए बिल्कुल सही जगह। मुझे अपने प्रोजेक्ट में कुछ समस्याएं थीं, मैं वहां जाकर लोगों के साथ बैठ गया। हमने इस पर 4 घंटे तक काम किया और आउटपुट आया। सबसे अच्छी बात यह थी कि हमें जो सेवा मिली, उससे हम बहुत प्रसन्न हुए और उसकी सराहना की गई। इंजीनियर स्टोर आपका बहुत बहुत धन्यवाद
बहुत अच्छी ग्राहक सेवा, हमेशा मदद के लिए तैयार। उन्होंने अपना काम छोड़कर लगातार 4 घंटे तक हमारे प्रोजेक्ट में हमारी मदद की। अंत में उन्होंने एक भी पैसा लेने से इंकार कर दिया। अद्भुत लोग
इस फॉर्म को पूरा करके, आप हमारे ईमेल प्राप्त करने के लिए साइन अप कर रहे हैं और किसी भी समय सदस्यता छोड़ सकते हैं।
FAQ Below are some of are common questions:
Shipping charge & Delivery timeline.
1) Standard shipping: Rs 49- The order gets delivered within 3-5 working days. (6-7 days in case of the battery as it travels through the surface)
2)Free shipping is applicable to the purchase of Rs.499 and above. The order gets delivered within 5-7 working days. (8-10 days in case of the battery as it travels through the surface)
3)Blue dart Air shipping Rs: 99 and above depending on parcel weight the order gets delivered within3-5working days.
4) Same-day delivery only applicable for Pune-specific pin codes Rs-79 delivery will be done same day between 1 p.m to 9 p.m (the order should be placed before 12:30 p.m)
How do I pay for my order?
You can pay through multiple payment options on theengineerstore.in the checkout page. You can pay through Credit/Debit Card, Internet Banking, Mobile Payments, Manual bank transfer, and Wallets. You can also apply a coupon that you might receive from The Engineer store or redeem The Engineer store points that you have earned from your previous purchases.
Cash on Delivery is offered theengineerstore.in and it is location dependent. Applicability of COD is determined by our system once you enter the pin-code of your area. Also the COD service is chargeable (Rs.25). It is charged by the shipping company for cash handlings.
Once you place a COD order, our executive will call you to confirm your order only after which your order will be processed.
It is best to prepay your order and buy confidently.
You can pay through multiple payment options on theengineerstore.in the checkout page. You can pay through Credit/Debit Card, Internet Banking, Mobile Payments, Manual bank transfer, and Wallets. You can also apply a coupon that you might receive from The Engineer store or redeem The Engineer store points that you have earned from your previous purchases.
Cash on Delivery is offered theengineerstore.in and it is location dependent. Applicability of COD is determined by our system once you enter the pin-code of your area. Also the COD service is chargeable (Rs.25). It is charged by the shipping company for cash handlings.
Once you place a COD order, our executive will call you to confirm your order only after which your order will be processed.
It is best to prepay your order and buy confidently.
It is understandable that a customer will have some technical query before making any purchase on theengineerstore.in.
No worries, we are there to answer your technical queries.
What customer needs to do?Submit a ticket mentioning1. Product code/SKU--->It is found on the product page.(just on the right hand side of the product image)2. Brief description of your query.Once we receive your query, we will get back to you soon with the possible answers.
It happens sometimes, In such cases the money is neither with us nor with the bank but if we receive your money without order, we will refund it within 2-3 working days. Rest assured, the money will come back to your bank account after 10-15 working days once the payment reconciliationhappens at bank's end.
If the money still does not reflect in your bank account, contact us and we will get back to you
What customer needs to do?
Submit a ticket mentioning1. Name of the customer2. Email ID used at the time of placing order.3. Any reference number of transaction that you received from bank.