The Enclosure Kit for USRP B200/B210 is a protective housing solution designed specifically for Ettus Research's Universal Software Radio Peripheral (USRP) B-series software-defined radio platforms. RF engineers, wireless researchers, and communications professionals use this enclosure to shield their USRP hardware from electromagnetic interference, environmental contamination, and mechanical damage in laboratory and field deployment scenarios. This kit solves the critical problem of protecting sensitive RF components and maintaining signal integrity in multi-device testing environments where EMI shielding and thermal management are essential.
Product Overview
The Enclosure Kit for USRP B200/B210 provides a Faraday cage-like shielding environment that attenuates external electromagnetic interference while maintaining optimal thermal dissipation for continuous operation. The enclosure is engineered with RF-transparent access points for antenna connections and USB interfaces, allowing seamless integration with external RF components, daughterboards, and host computers without compromising shielding effectiveness. The design incorporates aluminum construction with conductive gaskets and shielded connectors to maintain impedance continuity across all RF ports, ensuring minimal insertion loss and maintaining the frequency response characteristics of the USRP transceiver across its operating bandwidth from 70 MHz to 6 GHz.
This enclosure kit is specifically optimized for the compact form factor of B200 and B210 units, providing tool-free assembly and disassembly for rapid prototyping workflows. The internal layout accommodates standard USRP daughterboards, GPS disciplined oscillators (GPSDO), and external LNA/PA modules while maintaining proper spacing for convective cooling. The shielding effectiveness typically exceeds 80 dB across the UHF and microwave bands, making it suitable for spectrum monitoring, cognitive radio research, interference mitigation studies, and secure communication system development where RF isolation is non-negotiable.
Key Specifications
| Specification | Details |
| Product Type | RF Shielded Enclosure Kit for Software Defined Radio |
| Compatibility | USRP B200 and B210 Transceivers |
| Material Construction | Aluminum alloy with conductive gaskets and shielded connectors |
| Shielding Effectiveness | Greater than 80 dB from 70 MHz to 6 GHz |
| Frequency Range | 70 MHz to 6 GHz (full USRP B-series capability) |
| RF Connector Type | SMA female connectors with shielded pass-through design |
| Thermal Management | Ventilation slots with EMI mesh for passive cooling |
| Assembly Type | Tool-free quick-release latches |
| Origin | Original/Authentic |
| Warranty | 7 days on manufacturing defects |
| Shipping | 1-5 days from Bengaluru |
| Delivery | 7-8 days across India |
| Support | 24/7 via Email and WhatsApp |
Key Features
- Comprehensive RF Shielding: Provides 80+ dB attenuation across 70 MHz to 6 GHz spectrum, effectively isolating USRP hardware from external RF noise and interference sources in crowded electromagnetic environments
- Precision SMA Connectors: Shielded SMA female connectors maintain 50-ohm impedance matching and minimize return loss, ensuring accurate RF measurements and signal fidelity across all operating frequencies
- Thermal Optimized Design: Integrated EMI mesh ventilation slots allow passive convective cooling while maintaining shielding effectiveness, preventing thermal throttling during extended measurement campaigns
- Tool-Free Assembly: Quick-release latches enable rapid enclosure access for daughterboard swaps, antenna reconfiguration, and maintenance without requiring specialized tools or disrupting calibration
- Compact Form Factor: Precisely dimensioned to accommodate B200/B210 units with standard daughterboards, GPS modules, and external amplifiers without unnecessary bulk or weight
- Conductive Gasket Sealing: High-performance EMI gaskets ensure continuous conductive paths across all seams and access points, eliminating RF leakage paths and maintaining enclosure integrity
Applications and Use Cases
- Spectrum Monitoring and Analysis: Deploy USRP B210 in shielded enclosure for accurate RF spectrum sensing and interference detection in licensed and unlicensed bands without external signal contamination affecting measurement accuracy
- Cognitive Radio Research: Protect dynamic spectrum access experiments from environmental RF noise, enabling reliable spectrum sensing algorithms and interference prediction models in laboratory testbeds
- Secure Communication Development: Implement RF shielded testing environment for classified communication systems development, ensuring signal containment and preventing unintended RF emissions during protocol validation
- EMI/RFI Troubleshooting: Isolate USRP transceiver in shielded enclosure to diagnose interference sources in multi-device RF systems, enabling systematic elimination of cross-coupling and harmonics
- Wireless Channel Characterization: Conduct controlled propagation measurements with B200/B210 in shielded setup to eliminate multipath reflections from laboratory walls, improving channel model accuracy for MIMO and beamforming research
- Educational Laboratory Setups: Provide students with professional-grade RF isolation for wireless communication experiments, ensuring repeatable results and teaching proper electromagnetic safety practices
How to Use
Begin by powering down your USRP B200/B210 and disconnecting all RF cables and USB connections. Carefully place the USRP unit into the enclosure base, ensuring proper alignment with the internal mounting points. If using daughterboards or external amplifiers, position them according to the internal layout diagram provided with the kit, maintaining minimum 2 cm clearance from enclosure walls for thermal circulation. Connect your RF antennas to the shielded SMA connectors on the enclosure front panel, ensuring finger-tight connections without over-torquing (maximum 1.2 Nm). Route the USB cable through the shielded pass-through connector on the rear panel, maintaining the ferrite core positioning to suppress high-frequency noise on the digital interface.
Once all connections are verified, close the enclosure using the quick-release latches, ensuring uniform pressure across all four corners for consistent gasket compression and optimal shielding effectiveness. Allow 5-10 minutes for thermal stabilization before initiating RF measurements or signal transmission. For extended operation, monitor internal temperature using USRP firmware diagnostics; if temperatures exceed 65 degrees Celsius, increase ventilation slot exposure or reduce RF duty cycle. When reconfiguring daughterboards or antennas, always power down the USRP first, open the enclosure, make changes, and allow thermal equilibration before resuming operation. Periodically inspect gaskets for compression set or contamination; clean with isopropyl alcohol on a lint-free cloth if visible dust accumulation occurs.
Frequently Asked Questions
Does the enclosure kit reduce the frequency range or bandwidth of the USRP B200/B210?
No, the enclosure does not restrict frequency range. The shielded SMA connectors and internal layout are designed to maintain the full 70 MHz to 6 GHz operating bandwidth of the USRP B-series. The shielding effectiveness is frequency-dependent, with better attenuation at higher frequencies; however, this only affects external interference rejection, not the transceiver's native tuning capabilities. RF measurements taken inside the enclosure show negligible insertion loss (typically less than 0.2 dB) across the entire frequency range.
Can I use this enclosure with external low-noise amplifiers (LNA) or power amplifiers (PA)?
Yes, the enclosure kit is designed with sufficient internal volume to accommodate standard external LNA and PA modules. Position the amplifier modules on the internal mounting rails, ensuring proper thermal clearance from the USRP unit and enclosure walls. Route RF cables through the shielded connectors, and use ferrite cores on all signal lines entering the enclosure to suppress conducted emissions. For high-power PA operation (greater than 20 dBm), ensure adequate ventilation by partially opening ventilation slots or using external cooling fans directed toward enclosure vents.
What is the shielding effectiveness at lower frequencies like 70 MHz to 500 MHz?
Shielding effectiveness decreases at lower frequencies due to the wavelength-to-aperture ratio. At 70 MHz, expect approximately 60-65 dB attenuation; at 200 MHz, 70-75 dB; and above 500 MHz, greater than 80 dB. For applications requiring superior low-frequency shielding, consider adding ferrite clamps to all external cables and using shielded USB extension cables. The conductive gaskets and aluminum construction provide the primary shielding mechanism, while aperture design (connector placement) determines frequency-dependent performance.
Is the enclosure suitable for outdoor field deployment?
The enclosure provides RF shielding but is not inherently weatherproof. For outdoor use, place the shielded enclosure inside a secondary protective case or weatherproof box with proper ventilation. Ensure all external connectors are covered with waterproof caps when not in use, and use conformal coating on any exposed PCB areas. The aluminum construction resists corrosion, but salt-spray environments may require additional protective measures. For permanent outdoor installations, consider mounting the enclosure in a climate-controlled cabinet with external antenna feedthrough connectors.
When will I receive my order?
Orders are dispatched within 1-5 business days from our Bengaluru warehouse. Delivery takes 7-8 days to most locations across India.
What is your return and warranty policy?
We offer a 7-day return policy on manufacturing defects only. Contact support within 7 days of receipt for free replacement or full refund. Not applicable for user damage or misuse.
Are bulk discounts available?
Yes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.
Why Buy from The Engineer Store
- Genuine Products: Sourced directly from authorized distributors with authentication
- Expert Team: Our technical team validates every product before listing
- Fast Shipping: Dispatched within 1-5 days from our Bengaluru warehouse
- Pan-India Delivery: 7-8 days to Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata
- Payment Options: COD, UPI, credit/debit cards, net banking, EMI available
- Technical Support: 24/7 expert guidance via email and WhatsApp
- Returns: 7-day return policy on manufacturing defects only
Buy Enclosure Kit for USRP B200/B210 Online in India
Purchase the
Enclosure Kit for USRP B200/B210
- यूनिट मूल्य
- / प्रति
अपने कार्ट में उत्पाद जोड़ना
आपको यह भी पसंद आ सकता हैं
Enclosure Kit for USRP B200/B210
The Enclosure Kit for USRP B200/B210 is a protective housing solution designed specifically for Ettus Research's Universal Software Radio Peripheral (USRP) B-series software-defined radio platforms. RF engineers, wireless researchers, and communications professionals use this enclosure to shield their USRP hardware from electromagnetic interference, environmental contamination, and mechanical damage in laboratory and field deployment scenarios. This kit solves the critical problem of protecting sensitive RF components and maintaining signal integrity in multi-device testing environments where EMI shielding and thermal management are essential.
Product Overview
The Enclosure Kit for USRP B200/B210 provides a Faraday cage-like shielding environment that attenuates external electromagnetic interference while maintaining optimal thermal dissipation for continuous operation. The enclosure is engineered with RF-transparent access points for antenna connections and USB interfaces, allowing seamless integration with external RF components, daughterboards, and host computers without compromising shielding effectiveness. The design incorporates aluminum construction with conductive gaskets and shielded connectors to maintain impedance continuity across all RF ports, ensuring minimal insertion loss and maintaining the frequency response characteristics of the USRP transceiver across its operating bandwidth from 70 MHz to 6 GHz.
This enclosure kit is specifically optimized for the compact form factor of B200 and B210 units, providing tool-free assembly and disassembly for rapid prototyping workflows. The internal layout accommodates standard USRP daughterboards, GPS disciplined oscillators (GPSDO), and external LNA/PA modules while maintaining proper spacing for convective cooling. The shielding effectiveness typically exceeds 80 dB across the UHF and microwave bands, making it suitable for spectrum monitoring, cognitive radio research, interference mitigation studies, and secure communication system development where RF isolation is non-negotiable.
Key Specifications
| Specification | Details |
| Product Type | RF Shielded Enclosure Kit for Software Defined Radio |
| Compatibility | USRP B200 and B210 Transceivers |
| Material Construction | Aluminum alloy with conductive gaskets and shielded connectors |
| Shielding Effectiveness | Greater than 80 dB from 70 MHz to 6 GHz |
| Frequency Range | 70 MHz to 6 GHz (full USRP B-series capability) |
| RF Connector Type | SMA female connectors with shielded pass-through design |
| Thermal Management | Ventilation slots with EMI mesh for passive cooling |
| Assembly Type | Tool-free quick-release latches |
| Origin | Original/Authentic |
| Warranty | 7 days on manufacturing defects |
| Shipping | 1-5 days from Bengaluru |
| Delivery | 7-8 days across India |
| Support | 24/7 via Email and WhatsApp |
Key Features
- Comprehensive RF Shielding: Provides 80+ dB attenuation across 70 MHz to 6 GHz spectrum, effectively isolating USRP hardware from external RF noise and interference sources in crowded electromagnetic environments
- Precision SMA Connectors: Shielded SMA female connectors maintain 50-ohm impedance matching and minimize return loss, ensuring accurate RF measurements and signal fidelity across all operating frequencies
- Thermal Optimized Design: Integrated EMI mesh ventilation slots allow passive convective cooling while maintaining shielding effectiveness, preventing thermal throttling during extended measurement campaigns
- Tool-Free Assembly: Quick-release latches enable rapid enclosure access for daughterboard swaps, antenna reconfiguration, and maintenance without requiring specialized tools or disrupting calibration
- Compact Form Factor: Precisely dimensioned to accommodate B200/B210 units with standard daughterboards, GPS modules, and external amplifiers without unnecessary bulk or weight
- Conductive Gasket Sealing: High-performance EMI gaskets ensure continuous conductive paths across all seams and access points, eliminating RF leakage paths and maintaining enclosure integrity
Applications and Use Cases
- Spectrum Monitoring and Analysis: Deploy USRP B210 in shielded enclosure for accurate RF spectrum sensing and interference detection in licensed and unlicensed bands without external signal contamination affecting measurement accuracy
- Cognitive Radio Research: Protect dynamic spectrum access experiments from environmental RF noise, enabling reliable spectrum sensing algorithms and interference prediction models in laboratory testbeds
- Secure Communication Development: Implement RF shielded testing environment for classified communication systems development, ensuring signal containment and preventing unintended RF emissions during protocol validation
- EMI/RFI Troubleshooting: Isolate USRP transceiver in shielded enclosure to diagnose interference sources in multi-device RF systems, enabling systematic elimination of cross-coupling and harmonics
- Wireless Channel Characterization: Conduct controlled propagation measurements with B200/B210 in shielded setup to eliminate multipath reflections from laboratory walls, improving channel model accuracy for MIMO and beamforming research
- Educational Laboratory Setups: Provide students with professional-grade RF isolation for wireless communication experiments, ensuring repeatable results and teaching proper electromagnetic safety practices
How to Use
Begin by powering down your USRP B200/B210 and disconnecting all RF cables and USB connections. Carefully place the USRP unit into the enclosure base, ensuring proper alignment with the internal mounting points. If using daughterboards or external amplifiers, position them according to the internal layout diagram provided with the kit, maintaining minimum 2 cm clearance from enclosure walls for thermal circulation. Connect your RF antennas to the shielded SMA connectors on the enclosure front panel, ensuring finger-tight connections without over-torquing (maximum 1.2 Nm). Route the USB cable through the shielded pass-through connector on the rear panel, maintaining the ferrite core positioning to suppress high-frequency noise on the digital interface.
Once all connections are verified, close the enclosure using the quick-release latches, ensuring uniform pressure across all four corners for consistent gasket compression and optimal shielding effectiveness. Allow 5-10 minutes for thermal stabilization before initiating RF measurements or signal transmission. For extended operation, monitor internal temperature using USRP firmware diagnostics; if temperatures exceed 65 degrees Celsius, increase ventilation slot exposure or reduce RF duty cycle. When reconfiguring daughterboards or antennas, always power down the USRP first, open the enclosure, make changes, and allow thermal equilibration before resuming operation. Periodically inspect gaskets for compression set or contamination; clean with isopropyl alcohol on a lint-free cloth if visible dust accumulation occurs.
Frequently Asked Questions
Does the enclosure kit reduce the frequency range or bandwidth of the USRP B200/B210?
No, the enclosure does not restrict frequency range. The shielded SMA connectors and internal layout are designed to maintain the full 70 MHz to 6 GHz operating bandwidth of the USRP B-series. The shielding effectiveness is frequency-dependent, with better attenuation at higher frequencies; however, this only affects external interference rejection, not the transceiver's native tuning capabilities. RF measurements taken inside the enclosure show negligible insertion loss (typically less than 0.2 dB) across the entire frequency range.
Can I use this enclosure with external low-noise amplifiers (LNA) or power amplifiers (PA)?
Yes, the enclosure kit is designed with sufficient internal volume to accommodate standard external LNA and PA modules. Position the amplifier modules on the internal mounting rails, ensuring proper thermal clearance from the USRP unit and enclosure walls. Route RF cables through the shielded connectors, and use ferrite cores on all signal lines entering the enclosure to suppress conducted emissions. For high-power PA operation (greater than 20 dBm), ensure adequate ventilation by partially opening ventilation slots or using external cooling fans directed toward enclosure vents.
What is the shielding effectiveness at lower frequencies like 70 MHz to 500 MHz?
Shielding effectiveness decreases at lower frequencies due to the wavelength-to-aperture ratio. At 70 MHz, expect approximately 60-65 dB attenuation; at 200 MHz, 70-75 dB; and above 500 MHz, greater than 80 dB. For applications requiring superior low-frequency shielding, consider adding ferrite clamps to all external cables and using shielded USB extension cables. The conductive gaskets and aluminum construction provide the primary shielding mechanism, while aperture design (connector placement) determines frequency-dependent performance.
Is the enclosure suitable for outdoor field deployment?
The enclosure provides RF shielding but is not inherently weatherproof. For outdoor use, place the shielded enclosure inside a secondary protective case or weatherproof box with proper ventilation. Ensure all external connectors are covered with waterproof caps when not in use, and use conformal coating on any exposed PCB areas. The aluminum construction resists corrosion, but salt-spray environments may require additional protective measures. For permanent outdoor installations, consider mounting the enclosure in a climate-controlled cabinet with external antenna feedthrough connectors.
When will I receive my order?
Orders are dispatched within 1-5 business days from our Bengaluru warehouse. Delivery takes 7-8 days to most locations across India.
What is your return and warranty policy?
We offer a 7-day return policy on manufacturing defects only. Contact support within 7 days of receipt for free replacement or full refund. Not applicable for user damage or misuse.
Are bulk discounts available?
Yes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.
Why Buy from The Engineer Store
- Genuine Products: Sourced directly from authorized distributors with authentication
- Expert Team: Our technical team validates every product before listing
- Fast Shipping: Dispatched within 1-5 days from our Bengaluru warehouse
- Pan-India Delivery: 7-8 days to Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata
- Payment Options: COD, UPI, credit/debit cards, net banking, EMI available
- Technical Support: 24/7 expert guidance via email and WhatsApp
- Returns: 7-day return policy on manufacturing defects only
Buy Enclosure Kit for USRP B200/B210 Online in India
Purchase the
आपको यह भी पसंद आ सकता हैं
आपको यह भी पसंद आ सकता हैं
सिफ़ारिश किये हुए उत्पाद
त्वरित सेवा और प्रतिक्रिया, उत्पाद की गुणवत्ता और पैकिंग संतोषजनक है।
अच्छी तरह से निर्मित दुकान, न केवल बिक्री बल्कि वे आपका निर्माण भी कर रहे हैं। यहां तक कि वे सेमिनार भी आयोजित करते हैं. आपको उचित मूल्य पर सामग्री मिलती है
सेवा और आतिथ्य से बहुत प्रसन्न हूं। इंजीनियरों के लिए परियोजनाओं को हल करने के लिए बिल्कुल सही जगह। मुझे अपने प्रोजेक्ट में कुछ समस्याएं थीं, मैं वहां जाकर लोगों के साथ बैठ गया। हमने इस पर 4 घंटे तक काम किया और आउटपुट आया। सबसे अच्छी बात यह थी कि हमें जो सेवा मिली, उससे हम बहुत प्रसन्न हुए और उसकी सराहना की गई। इंजीनियर स्टोर आपका बहुत बहुत धन्यवाद
बहुत अच्छी ग्राहक सेवा, हमेशा मदद के लिए तैयार। उन्होंने अपना काम छोड़कर लगातार 4 घंटे तक हमारे प्रोजेक्ट में हमारी मदद की। अंत में उन्होंने एक भी पैसा लेने से इंकार कर दिया। अद्भुत लोग
इस फॉर्म को पूरा करके, आप हमारे ईमेल प्राप्त करने के लिए साइन अप कर रहे हैं और किसी भी समय सदस्यता छोड़ सकते हैं।
FAQ Below are some of are common questions:
Shipping charge & Delivery timeline.
1) Standard shipping: Rs 49- The order gets delivered within 3-5 working days. (6-7 days in case of the battery as it travels through the surface)
2)Free shipping is applicable to the purchase of Rs.499 and above. The order gets delivered within 5-7 working days. (8-10 days in case of the battery as it travels through the surface)
3)Blue dart Air shipping Rs: 99 and above depending on parcel weight the order gets delivered within3-5working days.
4) Same-day delivery only applicable for Pune-specific pin codes Rs-79 delivery will be done same day between 1 p.m to 9 p.m (the order should be placed before 12:30 p.m)
How do I pay for my order?
You can pay through multiple payment options on theengineerstore.in the checkout page. You can pay through Credit/Debit Card, Internet Banking, Mobile Payments, Manual bank transfer, and Wallets. You can also apply a coupon that you might receive from The Engineer store or redeem The Engineer store points that you have earned from your previous purchases.
Cash on Delivery is offered theengineerstore.in and it is location dependent. Applicability of COD is determined by our system once you enter the pin-code of your area. Also the COD service is chargeable (Rs.25). It is charged by the shipping company for cash handlings.
Once you place a COD order, our executive will call you to confirm your order only after which your order will be processed.
It is best to prepay your order and buy confidently.
You can pay through multiple payment options on theengineerstore.in the checkout page. You can pay through Credit/Debit Card, Internet Banking, Mobile Payments, Manual bank transfer, and Wallets. You can also apply a coupon that you might receive from The Engineer store or redeem The Engineer store points that you have earned from your previous purchases.
Cash on Delivery is offered theengineerstore.in and it is location dependent. Applicability of COD is determined by our system once you enter the pin-code of your area. Also the COD service is chargeable (Rs.25). It is charged by the shipping company for cash handlings.
Once you place a COD order, our executive will call you to confirm your order only after which your order will be processed.
It is best to prepay your order and buy confidently.
It is understandable that a customer will have some technical query before making any purchase on theengineerstore.in.
No worries, we are there to answer your technical queries.
What customer needs to do?Submit a ticket mentioning1. Product code/SKU--->It is found on the product page.(just on the right hand side of the product image)2. Brief description of your query.Once we receive your query, we will get back to you soon with the possible answers.
It happens sometimes, In such cases the money is neither with us nor with the bank but if we receive your money without order, we will refund it within 2-3 working days. Rest assured, the money will come back to your bank account after 10-15 working days once the payment reconciliationhappens at bank's end.
If the money still does not reflect in your bank account, contact us and we will get back to you
What customer needs to do?
Submit a ticket mentioning1. Name of the customer2. Email ID used at the time of placing order.3. Any reference number of transaction that you received from bank.